Chicago Pneumatic QRS 15 125 TM 15 HP Rotary Screw Air Compressor, 120-Gallon Tank - PN 4152023174

(0)
Regular price
$12,452.00
Sale price
$12,452.00
Regular price
$15,566.00
Sold out
Unit price
Quantity must be 1 or more

Chicago Pneumatic QRS 15 125 TM 15 HP Rotary Screw Air Compressor, 120-Gallon Tank - PN 4152023174

Quiet, Continuous-Duty Compressed Air for Demanding Shop and Industrial Applications

The Chicago Pneumatic QRS 15 125 TM Rotary Screw Air Compressor, part number 4152023174 , is a complete tank-mounted compressed-air package engineered for dependable performance, quiet operation, and continuous-duty use.

Powered by a 15 HP motor , this fixed-speed rotary screw compressor delivers 54.9 ACFM at 125 PSIG and is mounted on a 120-gallon horizontal ASME/CRN air receiver tank . The large receiver provides valuable compressed-air storage, helps stabilize system pressure, and supports short periods of increased air demand.

The Chicago Pneumatic QRS, or Quiet Rotary Screw, Series uses a single-stage, air-cooled, oil-injected rotary screw design. Its enclosed package provides smooth, pulse-free airflow with reduced vibration and an approximate sound level of 69 dBA , making it considerably quieter than many open-frame reciprocating compressors.

The QRS 15 125 TM is designed for automotive shops, tire stores, fleet maintenance facilities, fabrication operations, CNC equipment, woodworking businesses, manufacturing facilities, and other applications that require dependable compressed air throughout the workday.

The tri-voltage motor can be configured for 208, 230, or 460-volt three-phase electrical service , allowing the compressor to accommodate many common commercial and industrial power systems.

Manufacturer Part Number: 4152023174


Key Features and Benefits

54.9 ACFM at 125 PSIG

Delivers the airflow required for multiple pneumatic tools, production machinery, automotive equipment, CNC machines, and other high-demand compressed-air applications.

15 HP Fixed-Speed Rotary Screw Compressor

The fixed-speed design provides consistent compressor output for facilities with steady or predictable compressed-air demand.

Continuous-Duty Operation

The oil-injected rotary screw airend is designed for continuous operating capability, eliminating the cool-down periods commonly associated with reciprocating compressors.

120-Gallon Horizontal ASME/CRN Receiver Tank

The included receiver provides compressed-air storage, helps stabilize pressure, accommodates short periods of increased demand, and reduces rapid compressor cycling.

Complete Tank-Mounted Package

The compressor is factory mounted on the receiver tank, reducing installation complexity and eliminating the need to purchase and pipe a separate air receiver.

Quiet Enclosed Design

The low-sound enclosure limits compressor noise to approximately 69 dBA , allowing installation closer to active work areas when proper ventilation and service clearances are provided.

ES4000 Connect Controller

The ES4000 Connect controller provides straightforward monitoring and control of compressor operation.

Controller features include:

  • Pressure and temperature monitoring
  • Running-hour and working-hour tracking
  • Service warnings
  • Improved start-and-stop logic
  • Compressor operating-mode monitoring
  • Leak-detection functionality
  • ICONS connectivity for remote compressor monitoring

Remote-monitoring functionality may require network access, registration, and additional setup.

Tri-Voltage Three-Phase Motor

The motor can be configured for:

  • 208 volts, three phase
  • 230 volts, three phase
  • 460 volts, three phase
  • 60 Hz operation

Final voltage configuration and electrical installation should be completed by a qualified electrician.

Load/No-Load Operation

The compressor automatically loads and unloads according to system pressure and compressed-air demand, helping maintain stable airflow while reducing unnecessary loaded operation.

Spin-On Service Components

Spin-on oil-filter and air-oil separator components help simplify preventive maintenance and reduce service downtime.

Vibration-Isolated Assembly

Internal vibration isolation helps reduce vibration transferred to the receiver tank, surrounding floor, and connected piping system.


Standard Features

  • 15 HP rotary screw compressor
  • 54.9 ACFM at 125 PSIG
  • Low-sound enclosure
  • Approximately 69 dBA sound level
  • Continuous operating capability
  • Fixed-speed operation
  • Load/no-load control
  • Single-stage rotary screw airend
  • Oil-injected compression system
  • Air-cooled design
  • ES4000 Connect controller
  • 120-gallon horizontal ASME/CRN receiver tank
  • Spin-on oil filter
  • Spin-on air-oil separator
  • Integrated oil cooler
  • Cooling fan
  • Emergency-stop control
  • UL, cUL, and CSA-approved control panel
  • NEMA 1 electrical protection
  • Vibration-isolated compressor assembly
  • Tri-voltage three-phase motor
  • Tank-mounted configuration

Technical Specifications

Specification Details
Manufacturer Chicago Pneumatic
Model QRS 15 125 TM
Manufacturer Part Number 4152023174
Compressor Type Oil-injected rotary screw
Operating Type Fixed speed
Compression Stages Single stage
Motor Output 15 HP
Rated Airflow 54.9 ACFM
Rated Operating Pressure 125 PSIG
Maximum Full-Flow Pressure 132 PSIG
Receiver Tank Capacity 120 gallons
Receiver Certification ASME/CRN
Tank Orientation Horizontal
Mounting Configuration Tank mounted
Voltage 208-230/460V
Phase Three phase
Frequency 60 Hz
Cooling Method Air cooled
Controller ES4000 Connect
Approximate Sound Level 69 dBA
Integrated Refrigerated Dryer No
Electrical Protection NEMA 1
Duty Rating Continuous duty
Approximate Dimensions 76.2 × 25.4 × 57.9 inches
Approximate Weight 622 pounds

Recommended Applications

The Chicago Pneumatic QRS 15 125 TM is well suited for:

  • Automotive repair shops
  • Tire shops
  • Fleet maintenance facilities
  • Automotive dealerships
  • Collision repair and body shops
  • Paint and finishing operations
  • CNC machine shops
  • Metal fabrication facilities
  • Woodworking and cabinet shops
  • Pneumatic assembly equipment
  • Packaging facilities
  • Industrial maintenance departments
  • Light manufacturing
  • Production facilities
  • General industrial compressed-air systems

Air Treatment Recommendations

This compressor configuration does not include an integrated refrigerated air dryer . Compressed air naturally contains moisture, oil aerosols, and particulate contamination that may need to be removed before the air reaches downstream equipment.

Depending on the application, the compressed-air system may also require:

  • Refrigerated compressed-air dryer
  • Moisture separator
  • Automatic receiver-tank drain
  • General-purpose particulate filter
  • High-efficiency coalescing filter
  • Activated-carbon filter
  • Pressure regulator
  • Oil-water separator
  • Point-of-use filtration

Paint spraying, CNC machinery, instrumentation, automation equipment, and moisture-sensitive production processes normally require additional drying and filtration.

The dryer and filters should be sized according to compressor airflow, operating pressure, inlet temperature, ambient conditions, required air quality, and acceptable system pressure drop.


Installation Considerations

The compressor should be installed indoors on a level, structurally adequate surface with sufficient space for ventilation, inspection, and routine maintenance.

Before installation:

  1. Confirm that the facility has 208, 230, or 460-volt three-phase electrical service.
  2. Verify that total compressed-air demand is within the compressor’s 54.9 ACFM capacity.
  3. Confirm that piping, filters, dryers, and downstream equipment are rated for the operating pressure.
  4. Provide adequate ventilation around the compressor.
  5. Prevent heated cooling air from recirculating into the compressor intake.
  6. Install the required electrical disconnect and overcurrent protection.
  7. Use properly sized compressed-air piping.
  8. Install a flexible connection between the compressor and rigid piping.
  9. Verify that the receiver-tank condensate drain is installed and operating correctly.
  10. Route oily condensate to an approved oil-water separator or disposal system.
  11. Maintain the manufacturer’s recommended service clearances.
  12. Verify proper motor rotation during startup.
  13. Complete Chicago Pneumatic’s startup and warranty-registration requirements.

Electrical and mechanical installation should be completed according to Chicago Pneumatic’s instructions and all applicable local codes.


Routine Maintenance

Proper preventive maintenance helps protect compressor output, operating efficiency, temperature control, and equipment life.

Typical maintenance includes:

  • Check the compressor lubricant level.
  • Inspect and replace the intake air filter as needed.
  • Replace the oil filter at the recommended interval.
  • Replace the air-oil separator when required.
  • Use Chicago Pneumatic-approved rotary screw compressor lubricant.
  • Clean the oil cooler and cooling surfaces.
  • Inspect hoses, fittings, valves, and electrical connections.
  • Check the receiver tank and condensate drain.
  • Test the automatic condensate drain regularly.
  • Inspect the compressed-air system for leaks.
  • Keep the compressor room clean and properly ventilated.
  • Follow controller service warnings and maintenance intervals.
  • Maintain documentation required for extended-warranty coverage.

Maintenance intervals may vary depending on operating hours, ambient temperature, humidity, dust levels, and installation conditions.


Warranty Information

Chicago Pneumatic rotary screw compressors include a standard manufacturer’s warranty. Extended warranty coverage of up to five years on qualifying major components may be available when the compressor receives an authorized startup and is maintained according to Chicago Pneumatic requirements.

Warranty requirements may include:

  • Authorized compressor startup
  • Completed warranty registration
  • Use of approved compressor lubricant
  • Use of genuine Chicago Pneumatic maintenance parts
  • Maintenance performed at the required intervals
  • Retention of service and maintenance records

Complete warranty terms and requirements should be reviewed at the time of purchase.


Basic Troubleshooting

Compressor Cannot Maintain Pressure

Check for compressed-air leaks, an open condensate drain, a restricted intake filter, incorrect pressure settings, or downstream equipment consuming more than the available 54.9 ACFM.

Compressor Runs Hot or Shuts Down

Inspect room ventilation, ambient temperature, cooler cleanliness, lubricant level, intake restrictions, cooling-fan operation, and the possibility of heated cooling air recirculating into the compressor intake.

Compressor Loads and Unloads Frequently

Check for compressed-air leaks, rapidly changing air demand, incorrect pressure settings, an open condensate drain, or demand that is too low or inconsistent for the compressor.

Compressor Does Not Start

Check the electrical disconnect, incoming voltage, fuses, circuit protection, emergency-stop control, controller settings, and any active fault or shutdown condition.

Compressor Rotation Is Incorrect

Three-phase electrical connections may need to be corrected to achieve proper motor rotation. Disconnect power and have a qualified electrician correct the phase rotation before operating the compressor.

Excessive Moisture Downstream

Check the receiver-tank drain and condensate-removal equipment. Install a properly sized refrigerated dryer, moisture separator, and filtration system when dry compressed air is required.

Excessive Pressure Drop

Inspect compressed-air filters, piping size, isolation valves, regulators, and filter elements for restrictions or contamination.

Controller Displays a Warning or Fault

Record the warning or fault information and consult the operating manual. Do not repeatedly reset protective shutdowns without identifying and correcting the underlying cause.

Electrical repairs, internal pressure-system repairs, controller repairs, and major compressor service should be completed by qualified service personnel.


Frequently Asked Questions

How much air does the Chicago Pneumatic QRS 15 125 TM produce?

The Chicago Pneumatic QRS 15 125 TM delivers 54.9 ACFM at 125 PSIG .

What is the manufacturer part number?

The manufacturer part number for this compressor is 4152023174 .

What size air receiver tank is included?

This compressor is mounted on a 120-gallon horizontal ASME/CRN air receiver tank .

Does this compressor include a refrigerated air dryer?

No. This configuration does not include an integrated refrigerated air dryer. A separate dryer can be added when moisture removal is required.

Is this a single-phase compressor?

No. This model requires three-phase electrical power .

What voltages can this compressor use?

The motor can be configured for 208, 230, or 460-volt three-phase power .

Can this compressor operate continuously?

Yes. The QRS rotary screw compressor is designed for continuous-duty applications when properly sized, installed, ventilated, and maintained.

How loud is the Chicago Pneumatic QRS 15?

The compressor has an approximate sound rating of 69 dBA , making it quieter than many traditional open-frame reciprocating compressors.

What does the ES4000 Connect controller monitor?

The controller tracks compressor pressure, temperature, running hours, working hours, operating mode, and service requirements. It also supports leak detection and remote monitoring through Chicago Pneumatic’s ICONS technology.

Can this compressor operate multiple air tools?

Yes, provided the combined air consumption of the tools and equipment operating at the same time does not exceed the compressor’s rated output of 54.9 ACFM.

Is this compressor suitable for CNC equipment?

Yes. Its continuous-duty performance, stable airflow, large receiver tank, and 54.9 ACFM output make it a strong option for properly sized CNC and manufacturing applications.

Can this compressor be used for paint applications?

Yes, when properly sized. Paint applications normally require a refrigerated air dryer, coalescing filtration, and appropriate point-of-use air treatment.

Why choose a rotary screw compressor instead of a piston compressor?

A rotary screw compressor provides continuous-duty capability, smoother airflow, reduced vibration, quieter operation, and longer operating cycles compared with many traditional reciprocating compressors.

What is the difference between fixed-speed and variable-speed operation?

A fixed-speed compressor runs its motor at a constant speed and loads or unloads according to air demand. It is generally best suited for facilities with steady or predictable compressed-air usage.

How do I determine whether 54.9 ACFM is enough?

Add the CFM requirements of all tools and equipment that may operate simultaneously. Include additional capacity for compressed-air leaks, periods of peak demand, and future growth.


Why Buy from Compressed Air Advisors Online?

Compressed Air Advisors Online provides more than equipment in a box. Our team offers knowledgeable product-selection assistance, compressed-air system guidance, premium industrial manufacturers, and nationwide delivery.

We can help determine whether the Chicago Pneumatic QRS 15 125 TM provides the correct airflow, pressure, electrical configuration, storage capacity, and air quality for your application.

When you need dependable compressed-air equipment supported by real-world application knowledge, Compressed Air Advisors Online is your compressed-air partner.