Hankison VNCA100-FP Non-Cycling Refrigerated Air Dryer – 100 SCFM, 115V/1Ph with Pre & Post Filtration
Reliable Compressed Air Drying with Complete Pre & Post Filtration
The Hankison VNCA100-FP Non-Cycling Refrigerated Air Dryer provides dependable moisture removal and filtration for compressed air systems requiring up to 100 SCFM of treated air. Designed for industrial compressed air applications, the VNCA100-FP combines refrigerated air drying with matched Hankison pre and post filtration in one complete air treatment package.
Operating on convenient 115V single-phase power , the VNCA100-FP uses R513A low-GWP refrigerant and consumes just 0.55 kW at full rated capacity. Its compact footprint makes it an excellent choice for compressor rooms, manufacturing facilities, machine shops, maintenance departments, and other facilities where reliable moisture control is required.
The VNCA100-FP includes a Hankison F07-PF-DP1 prefilter and F07-HF-DP1 afterfilter , providing filtration before and after the refrigerated dryer for cleaner, drier compressed air throughout your system.
Key Features & Benefits
100 SCFM Rated Capacity
- Rated for 100 SCFM
- Designed for medium-size industrial compressed air systems
- Helps remove moisture before it reaches downstream piping and equipment
- Rated in accordance with ISO 7183 Option A2 conditions
Complete Pre & Post Filtration Package
- Pre and post filtration included
- Prefilter: F07-PF-DP1
- Afterfilter: F07-HF-DP1
- Prefiltration helps protect the dryer from incoming contaminants
- Afterfiltration provides additional compressed air treatment downstream
- Complete dryer and filtration package eliminates the need to separately select matching filters
Non-Cycling Refrigerated Dryer Design
- Proven non-cycling refrigerated drying technology
- Provides continuous moisture removal during operation
- Helps reduce water-related problems in compressed air piping and equipment
- Straightforward design for dependable industrial operation
R513A Refrigerant
- Uses R513A refrigerant
- Low-GWP refrigerant designed for improved environmental sustainability
- Provides efficient refrigerated dryer performance
Low Power Consumption
- Consumes only 0.55 kW
- Provides effective compressed air drying with low electrical demand
- Designed for efficient operation at full rated capacity
115V Single-Phase Power
- 115V / 1Ph / 60 Hz
- No three-phase electrical service required
- Makes installation easier in shops and facilities with standard single-phase power
- Expands installation flexibility compared with larger three-phase-only dryers
Compact Industrial Design
- 21.0" W x 22.6" D x 25.0" H
- Approximately 92 lbs.
- Compact footprint allows flexible installation
- 3/4" female NPT inlet and outlet connections
Condensate Removal
- Condensate drain furnished with the dryer
- 1/8" FNPT drain connection
- Removes moisture collected during the refrigeration process
- Helps maintain dependable dryer operation
UL & CSA Certified
- Third-party certified to applicable UL and CSA standards
- Designed for safe operation in the United States and Canada
Ideal Applications
The Hankison VNCA100-FP is well suited for:
- Manufacturing facilities
- Machine shops
- CNC equipment
- Automotive and service shops
- Woodworking facilities
- Maintenance departments
- Packaging equipment
- Pneumatic tools and controls
- Rotary screw compressor systems
- Reciprocating compressor systems
- General industrial compressed air systems
Technical Specifications
| Specification | Hankison VNCA100-FP |
|---|---|
| Rated Air Flow | 100 SCFM |
| Metric Air Flow | 170 Nm³/H |
| Dryer Type | Non-Cycling Refrigerated |
| Voltage | 115V / 1Ph / 60 Hz |
| Power Consumption | 0.55 kW |
| Refrigerant | R513A |
| Air Inlet / Outlet | 3/4" Female NPT |
| Condensate Drain Connection | 1/8" FNPT |
| Width | 21.0" |
| Depth | 22.6" |
| Height | 25.0" |
| Shipping Weight | 92 lbs. |
| Prefilter | F07-PF-DP1 |
| Afterfilter | F07-HF-DP1 |
| Filtration | Pre & Post Filtration Included |
Frequently Asked Questions
How much compressed air can the Hankison VNCA100-FP handle?
The Hankison VNCA100-FP is rated for 100 SCFM under ISO 7183 Option A2 rating conditions. Actual capacity can vary depending on operating pressure, compressed air inlet temperature, ambient temperature, and airflow demand.
Does the VNCA100-FP include air filters?
Yes. The VNCA100-FP includes both a Hankison F07-PF-DP1 prefilter and F07-HF-DP1 afterfilter , providing filtration before and after the refrigerated dryer.
Why is pre and post filtration important?
The prefilter helps remove contaminants before compressed air enters the dryer, helping protect the dryer and improve overall air treatment. The afterfilter provides additional filtration before compressed air enters the facility's distribution system or downstream equipment.
What voltage does the VNCA100-FP require?
The VNCA100-FP operates on 115V / 1-phase / 60 Hz power , allowing installation without the need for three-phase electrical service.
What size air connections does the VNCA100-FP use?
The dryer uses 3/4-inch female NPT inlet and outlet connections .
What refrigerant does the Hankison VNCA100 use?
The VNCA100 uses R513A refrigerant , a low-GWP refrigerant designed to provide efficient refrigerated drying while supporting improved environmental sustainability.
What are the rated conditions for the VNCA100-FP?
Hankison rates VNCA Series capacity in accordance with ISO 7183 Option A2 at:
- 100 PSIG inlet pressure
- 100°F compressed air inlet temperature
- 100°F ambient temperature
- 60 Hz electrical supply
Does the VNCA100-FP include a condensate drain?
Yes. The VNCA100-FP is furnished with a condensate drain to efficiently remove moisture separated from the compressed air.