The Super-Dry SAF-375 Compressed Air Filter, PN 340-130, is a high-capacity industrial compressed air filter housing designed for applications requiring up to 375 SCFM of compressed air filtration. The SAF-375 is rated for 370 SCFM at 100 PSIG and features 1-1/2″ NPT inlet and outlet connections.
Available with Grade X, Y, or Z filtration, the SAF-375 can be configured for general-purpose particulate removal, high-efficiency coalescing filtration, or activated carbon filtration. An internal float drain and differential pressure indicator are included.
Full Product Description
The Super-Dry SAF-375 Compressed Air Filter, SKU 340-130, provides reliable compressed air filtration for larger industrial air systems. Designed for airflow requirements up to approximately 375 SCFM, the SAF-375 has a published capacity of 370 SCFM at 100 PSIG and uses 1-1/2″ NPT inlet and outlet connections.
Super-Dry SAF Series filters are designed to remove up to 99% of contaminants present in compressed air. Cleaner compressed air helps extend air-tool service life, maintain the performance of pneumatic machinery and control systems, and keep downstream piping and valves free from contamination.
The SAF-375 accepts Super-Dry E-375 filter elements in three filtration grades, allowing the filter housing to be configured around the air-quality requirements of the application. The housing also includes a float drain and differential pressure indicator, making condensate management and filter-condition monitoring easier.
Key Features
- SKU / Part Number: 340-130
- Model: SAF-375
- Designed for compressed air systems up to 375 SCFM
- Rated airflow of 370 SCFM at 100 PSIG
- 1-1/2″ NPT inlet and outlet connections
- Maximum inlet pressure of 232 PSIG
- Maximum inlet temperature of 176°F (80°C)
- Float drain included
- Differential pressure indicator included
- Uses E-375 replacement filter elements
- Available in Grade X, Grade Y, and Grade Z
- Suitable for industrial compressed air treatment applications
The manufacturer's specification table confirms the SAF-375's 370 SCFM rating, 1-1/2″ NPT connections, E-375 element size, and 6 lb. housing weight.
Benefits
Protects Downstream Equipment
Proper compressed air filtration helps prevent particulate, oil aerosol, and other contamination from reaching pneumatic tools, valves, controls, and production equipment.
Improves Compressed Air Quality
Three available element grades allow the SAF-375 to be configured for anything from general plant-air filtration to high-efficiency oil removal and activated carbon filtration.
Automatic Condensate Removal
The included float drain automatically removes collected condensate from the filter housing, reducing the need for manual draining.
Filter Condition Monitoring
The included differential pressure indicator provides a convenient visual reference for monitoring pressure differential across the filter element.
High Airflow Capacity
With a rated flow of 370 SCFM at 100 PSIG, the SAF-375 is designed for larger compressed air systems while maintaining a compact 1-1/2″ NPT connection size.
Best For
The Super-Dry SAF-375 is well suited for:
- Manufacturing facilities
- Industrial compressed air systems
- CNC machinery
- Pneumatic production equipment
- Air-operated tools
- Instrument and control air
- Paint and finishing applications
- Refrigerated air dryer pre-filtration
- Compressed air dryer post-filtration
- General plant air filtration
Technical Specifications
Specification Details Manufacturer Super-Dry Series SAF Series Model SAF-375 SKU / Part Number 340-130 Maximum Nominal Capacity Up to 375 SCFM Rated Airflow 370 SCFM @ 100 PSIG Inlet / Outlet 1-1/2″ NPT Maximum Inlet Pressure 232 PSIG Maximum Inlet Temperature 176°F (80°C) Replacement Element E-375 Available Grades X / Y / Z Float Drain Included Differential Pressure Indicator Included Dimensions A / B / C 5″ / 15″ / 13.5″ Weight 6 lbs. HS Code 8421.39.0115 SAF-375 Filter Element Options
Grade X – General Purpose / Particulate
The Grade X element is designed for general-purpose compressed air filtration and particulate removal.
- Solid particles: 1.0 micron
- Oil carryover: 0.5 ppm
- Pressure drop: 0.44 PSI
Grade X is a good choice for general plant air, pneumatic equipment protection, and applications requiring removal of larger particulate contaminants.
Grade Y – High Efficiency / Oil Removal
The Grade Y element provides high-efficiency coalescing filtration for applications requiring substantially cleaner compressed air.
- Solid particles: 0.01 micron
- Oil carryover: 0.01 ppm
- Pressure drop: 1.74 PSI
Grade Y is appropriate where fine particulate and oil aerosol removal are required.
Grade Z – Activated Carbon / Odor & Taste
The Grade Z activated carbon element is designed for applications requiring extremely low residual oil contamination as well as odor and taste removal.
- Oil carryover: 0.003 ppm
- Pressure drop: 1.31 PSI
Super-Dry identifies the three available element grades as Grade X particulate, Grade Y high efficiency, and Grade Z activated carbon filtration.
Choosing the Correct Filter Grade
Choose Grade X for general-purpose particulate filtration and basic protection of downstream equipment.
Choose Grade Y when fine particulate and oil aerosol removal are required.
Choose Grade Z when activated carbon filtration is needed for extremely low residual oil levels and odor or taste removal.
For applications requiring progressively cleaner compressed air, multiple SAF Series filters with different element grades can be installed in sequence.
Why Choose the Super-Dry SAF-375?
The Super-Dry SAF-375 combines a 370 SCFM rated airflow, 1-1/2″ NPT connections, automatic condensate drainage, differential pressure monitoring, and three available filtration grades in one industrial filter housing.
Its flexible element options make the SAF-375 suitable for a wide range of compressed air treatment applications, whether it is being used for general equipment protection, as part of an air dryer installation, or in a multi-stage filtration system.
Why Buy From Compressed Air Advisors Online?
Compressed Air Advisors specializes in compressed air equipment and air-treatment systems. We can help you determine the correct filter size, filtration grade, and placement within your compressed air system.
Whether you're replacing an existing filter or designing a complete compressed air system with a compressor, dryer, filters, drains, and receiver tanks, our team can help make sure the components are properly matched.
Frequently Asked Questions
What is the airflow capacity of the Super-Dry SAF-375?
The SAF-375 is designed for applications up to approximately 375 SCFM and is specifically rated for 370 SCFM at 100 PSIG.
What is the part number for the Super-Dry SAF-375?
The Super-Dry SAF-375 compressed air filter housing is SKU / Part Number 340-130.
What size connections does the SAF-375 use?
The SAF-375 uses 1-1/2″ NPT inlet and outlet connections.
What filter element does the SAF-375 use?
The SAF-375 uses a Super-Dry E-375 filter element, available in Grade X, Grade Y, and Grade Z.
What is the difference between Grade X, Y, and Z?
Grade X provides general-purpose particulate filtration. Grade Y provides high-efficiency fine particulate and oil aerosol filtration. Grade Z uses activated carbon for extremely low residual oil levels and odor or taste removal.
Does the SAF-375 include a drain?
Yes. A float drain is included with the SAF-375 filter housing.
Does the SAF-375 include a differential pressure indicator?
Yes. A differential pressure indicator is included.
What is the maximum pressure rating?
The SAF-375 has a maximum inlet pressure rating of 232 PSIG.
What is the maximum inlet temperature?
The maximum inlet temperature is 176°F (80°C).
Can the SAF-375 be installed before a refrigerated air dryer?
Yes. When equipped with the appropriate element grade, the SAF-375 can be used as pre-filtration for a refrigerated compressed air dryer. The correct filtration grade should be selected based on the dryer manufacturer's requirements.