{"product_id":"altec-air-hbs-0200-2-200-cfm-single-tower-desiccant-air-dryer","title":"Altec AIR HBS-0200-2 200 CFM Single Tower Desiccant Air Dryer","description":"\u003cdiv class=\"item-blurb\" style=\"font-size:16px;line-height:1.65;color:inherit;\"\u003e\n\u003ch2 style=\"font-size:22px;line-height:1.35;font-weight:700;margin:0 0 18px;\"\u003eAltec AIR HBS-0200-2 — 200 CFM Single Tower Desiccant Air Dryer\u003c\/h2\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003e\u003cstrong\u003eMade in the USA.\u003c\/strong\u003e The Altec AIR HBS-0200-2 brings \u003cstrong\u003esingle-tower simplicity, heated blower regeneration, and factory-installed filtration\u003c\/strong\u003e to industrial compressed air drying. Rated for 200 SCFM inlet flow at 100 PSIG, it delivers a complete desiccant drying package for moisture-sensitive tools, equipment, and processes.\u003c\/p\u003e\n\u003ch3 style=\"font-size:20px;line-height:1.4;font-weight:700;margin:28px 0 12px;\"\u003eWhat Makes the HBS Series Unique?\u003c\/h3\u003e\n\u003cul style=\"font-size:16px;line-height:1.65;list-style-type:disc;padding-left:24px;margin:0 0 20px;\"\u003e\n\u003cli style=\"display:list-item;margin:0 0 8px;\"\u003e\n\u003cstrong\u003eOne tower, fewer moving parts:\u003c\/strong\u003e a rugged design with only three moving parts and no moving parts during the drying cycle.\u003c\/li\u003e\n\u003cli style=\"display:list-item;margin:0 0 8px;\"\u003e\n\u003cstrong\u003eHeater and blower regeneration:\u003c\/strong\u003e reconditions the desiccant offline for the next drying cycle.\u003c\/li\u003e\n\u003cli style=\"display:list-item;margin:0 0 8px;\"\u003e\n\u003cstrong\u003eFilters included:\u003c\/strong\u003e factory-installed pre- and after-filtration form an integrated package.\u003c\/li\u003e\n\u003cli style=\"display:list-item;margin:0 0 8px;\"\u003e\n\u003cstrong\u003eSubfreezing dew point capability:\u003c\/strong\u003e published outlet dew points of 0°F to -50°F, subject to sizing and conditions.\u003c\/li\u003e\n\u003cli style=\"display:list-item;margin:0 0 8px;\"\u003e\n\u003cstrong\u003eNo refrigerant circuit:\u003c\/strong\u003e desiccant adsorption removes water vapor without a refrigeration compressor.\u003c\/li\u003e\n\u003cli style=\"display:list-item;margin:0 0 8px;\"\u003e\n\u003cstrong\u003eMade in the USA:\u003c\/strong\u003e American-made Altec AIR industrial drying equipment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"font-size:20px;line-height:1.4;font-weight:700;margin:28px 0 12px;\"\u003eOverview \u0026amp; Applications\u003c\/h3\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eA strong fit for shops and production facilities that need low-moisture compressed air and can schedule time for regeneration between drying periods. A single-tower system offers a straightforward alternative where uninterrupted drying through regeneration is not required.\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003e\u003cstrong\u003ePlan for offline regeneration.\u003c\/strong\u003e This tower cannot dry process air while it is regenerating, cooling, and repressurizing. Allow suitable downtime or provide an alternate dry-air source. The optional bypass provides an untreated-air path; it does not provide continuous dry air.\u003c\/p\u003e\n\u003ch3 style=\"font-size:20px;line-height:1.4;font-weight:700;margin:28px 0 12px;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"font-size:16px;line-height:1.65;list-style-type:disc;padding-left:24px;margin:0 0 20px;\"\u003e\n\u003cli style=\"display:list-item;margin:0 0 8px;\"\u003e\n\u003cstrong\u003e200 SCFM rated inlet flow\u003c\/strong\u003e at 100 PSIG.\u003c\/li\u003e\n\u003cli style=\"display:list-item;margin:0 0 8px;\"\u003e\n\u003cstrong\u003e230 VAC \/ 1 Phase \/ 60 Hz\u003c\/strong\u003e standard electrical supply.\u003c\/li\u003e\n\u003cli style=\"display:list-item;margin:0 0 8px;\"\u003e\n\u003cstrong\u003e200 PSIG maximum pressure standard\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli style=\"display:list-item;margin:0 0 8px;\"\u003eLow watt density heater and industrial duty blower.\u003c\/li\u003e\n\u003cli style=\"display:list-item;margin:0 0 8px;\"\u003eThree-way electric ball valves for dryer operation; optional system bypass selected separately.\u003c\/li\u003e\n\u003cli style=\"display:list-item;margin:0 0 8px;\"\u003ePackaged filtration: published oil removal efficiency of 99.9% at 0.3–0.6 microns and particle removal efficiency of 99.9% at 1 micron. These figures do not mean complete oil-vapor removal.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"font-size:20px;line-height:1.4;font-weight:700;margin:28px 0 12px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;font-size:16px;line-height:1.5;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px 12px;border-bottom:1px solid #ddd;width:42%;vertical-align:top;\"\u003eBase Manufacturer Part Number\u003c\/th\u003e\n\u003ctd style=\"padding:10px 12px;border-bottom:1px solid #ddd;vertical-align:top;\"\u003eHBS-0200-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px 12px;border-bottom:1px solid #ddd;width:42%;vertical-align:top;\"\u003eDryer Type\u003c\/th\u003e\n\u003ctd style=\"padding:10px 12px;border-bottom:1px solid #ddd;vertical-align:top;\"\u003eSingle tower heat regenerative desiccant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px 12px;border-bottom:1px solid #ddd;width:42%;vertical-align:top;\"\u003eRated Inlet Flow\u003c\/th\u003e\n\u003ctd style=\"padding:10px 12px;border-bottom:1px solid #ddd;vertical-align:top;\"\u003e200 SCFM at 100 PSIG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px 12px;border-bottom:1px solid #ddd;width:42%;vertical-align:top;\"\u003eOutlet Dew Point\u003c\/th\u003e\n\u003ctd style=\"padding:10px 12px;border-bottom:1px solid #ddd;vertical-align:top;\"\u003e0°F to -50°F; application and sizing dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px 12px;border-bottom:1px solid #ddd;width:42%;vertical-align:top;\"\u003eElectrical Supply\u003c\/th\u003e\n\u003ctd style=\"padding:10px 12px;border-bottom:1px solid #ddd;vertical-align:top;\"\u003e230 VAC \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px 12px;border-bottom:1px solid #ddd;width:42%;vertical-align:top;\"\u003eInlet \/ Outlet Connections\u003c\/th\u003e\n\u003ctd style=\"padding:10px 12px;border-bottom:1px solid #ddd;vertical-align:top;\"\u003e1-1\/2\" NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px 12px;border-bottom:1px solid #ddd;width:42%;vertical-align:top;\"\u003eMaximum Operating Pressure\u003c\/th\u003e\n\u003ctd style=\"padding:10px 12px;border-bottom:1px solid #ddd;vertical-align:top;\"\u003e200 PSIG standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px 12px;border-bottom:1px solid #ddd;width:42%;vertical-align:top;\"\u003eFiltration\u003c\/th\u003e\n\u003ctd style=\"padding:10px 12px;border-bottom:1px solid #ddd;vertical-align:top;\"\u003eFactory-installed pre-filter and after-filter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px 12px;border-bottom:1px solid #ddd;width:42%;vertical-align:top;\"\u003eApproximate Dimensions\u003c\/th\u003e\n\u003ctd style=\"padding:10px 12px;border-bottom:1px solid #ddd;vertical-align:top;\"\u003e46\" W × 30\" D × 78\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px 12px;border-bottom:1px solid #ddd;width:42%;vertical-align:top;\"\u003eApproximate Base Weight\u003c\/th\u003e\n\u003ctd style=\"padding:10px 12px;border-bottom:1px solid #ddd;vertical-align:top;\"\u003e590 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px 12px;border-bottom:1px solid #ddd;width:42%;vertical-align:top;\"\u003eCountry of Manufacture\u003c\/th\u003e\n\u003ctd style=\"padding:10px 12px;border-bottom:1px solid #ddd;vertical-align:top;\"\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3 style=\"font-size:20px;line-height:1.4;font-weight:700;margin:28px 0 12px;\"\u003eChoose Your Factory Options\u003c\/h3\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003e\u003cstrong\u003e3 Way Bypass Installed:\u003c\/strong\u003e choose \u003cstrong\u003eNo\u003c\/strong\u003e or \u003cstrong\u003eYes\u003c\/strong\u003e. The bypass lets air flow around the dryer when required for service or isolation. Air routed around the dryer is not dried.\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003e\u003cstrong\u003e200 PSI standard:\u003c\/strong\u003e this model includes the 200 PSIG rating without a pressure upgrade.\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eNeed insulation, low-ambient protection, alternate voltage, or another factory configuration? Call \u003cstrong\u003e877.247.2381\u003c\/strong\u003e for selection and pricing. Those options are not included unless specifically ordered.\u003c\/p\u003e\n\u003ch3 style=\"font-size:20px;line-height:1.4;font-weight:700;margin:28px 0 12px;\"\u003eLead Time\u003c\/h3\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eContact us for current factory availability and an estimated ship date for your selected configuration. Confirm delivery requirements before placing a time-sensitive order.\u003c\/p\u003e\n\u003ch3 style=\"font-size:20px;line-height:1.4;font-weight:700;margin:28px 0 12px;\"\u003eWhat's Included\u003c\/h3\u003e\n\u003cul style=\"font-size:16px;line-height:1.65;list-style-type:disc;padding-left:24px;margin:0 0 20px;\"\u003e\n\u003cli style=\"display:list-item;margin:0 0 8px;\"\u003eHBS-0200-2 single-tower desiccant air dryer package.\u003c\/li\u003e\n\u003cli style=\"display:list-item;margin:0 0 8px;\"\u003eFactory-installed pre-filter and after-filter.\u003c\/li\u003e\n\u003cli style=\"display:list-item;margin:0 0 8px;\"\u003eRegeneration heater, blower, and dryer operating valves.\u003c\/li\u003e\n\u003cli style=\"display:list-item;margin:0 0 8px;\"\u003eFactory-installed 3-way system bypass only when Yes is selected.\u003c\/li\u003e\n\u003cli style=\"display:list-item;margin:0 0 8px;\"\u003eStandard 200 PSIG pressure rating.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eInstallation piping, electrical connection, unloading, and site preparation are not included. Photo represents the HBS series; actual configuration and dimensions vary by model.\u003c\/p\u003e\n\u003ch3 style=\"font-size:20px;line-height:1.4;font-weight:700;margin:28px 0 12px;\"\u003eRelated Products \u0026amp; Selection Help\u003c\/h3\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003e\u003ca href=\"\/products\/altec-air-hrl-0200-1-200-cfm-desiccant-air-dryer\" style=\"color:#0056b3 !important;text-decoration:underline !important;font-weight:700 !important;\"\u003eExplore the Altec AIR HRL 200 CFM twin-tower dryer →\u003c\/a\u003e For applications requiring drying through regeneration, ask us to size an appropriate twin-tower model. Allow for regeneration purge consumption when sizing a twin-tower dryer; matching inlet CFM alone does not establish equivalent usable output.\u003c\/p\u003e\n\u003ch3 style=\"font-size:20px;line-height:1.4;font-weight:700;margin:28px 0 12px;\"\u003eWarranty\u003c\/h3\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003e\u003cstrong\u003eTwo-year limited manufacturer warranty from the date of shipment.\u003c\/strong\u003e Year one includes qualifying parts and labor under Altec AIR's warranty schedule; year two is parts only with valid registration and documented maintenance. Consumables, exclusions, installation requirements, and claim procedures are subject to manufacturer terms.\u003c\/p\u003e\n\u003ch3 style=\"font-size:20px;line-height:1.4;font-weight:700;margin:28px 0 12px;\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4 style=\"font-size:17px;line-height:1.5;font-weight:700;margin:20px 0 6px;\"\u003eWhat makes the HBS different from other desiccant dryers?\u003c\/h4\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eIt uses one desiccant tower with a heater and blower for offline regeneration. Factory-installed pre- and after-filters, only three moving parts, and no moving parts during the drying cycle make it a simple packaged option.\u003c\/p\u003e\n\u003ch4 style=\"font-size:17px;line-height:1.5;font-weight:700;margin:20px 0 6px;\"\u003eDoes it supply dried air while regenerating?\u003c\/h4\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eNo. The single tower regenerates offline and must cool and repressurize before drying resumes. Plan regeneration during downtime or provide another dry-air source. A bypass passes untreated air and does not replace a second drying tower.\u003c\/p\u003e\n\u003ch4 style=\"font-size:17px;line-height:1.5;font-weight:700;margin:20px 0 6px;\"\u003eHow much airflow can the HBS-0200-2 handle?\u003c\/h4\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eRated inlet flow is 200 SCFM at 100 PSIG. Actual selection also depends on inlet temperature, pressure, moisture loading, required dew point, and available time between drying cycles. Contact us to confirm application sizing.\u003c\/p\u003e\n\u003ch4 style=\"font-size:17px;line-height:1.5;font-weight:700;margin:20px 0 6px;\"\u003eWhat dew point can it achieve?\u003c\/h4\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eThe HBS series offers outlet dew points from 0°F to as low as -50°F, depending on operating conditions and application sizing. Do not assume -50°F is guaranteed at every airflow and duty cycle.\u003c\/p\u003e\n\u003ch4 style=\"font-size:17px;line-height:1.5;font-weight:700;margin:20px 0 6px;\"\u003eAre pre-filters and after-filters included?\u003c\/h4\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eYes. Factory-installed pre- and after-filters are included. Maintain the filter elements and desiccant according to Altec AIR instructions. Separate RAD refrigerated dryer filter kits are not required for the standard HBS package.\u003c\/p\u003e\n\u003ch4 style=\"font-size:17px;line-height:1.5;font-weight:700;margin:20px 0 6px;\"\u003eWhat does the 3-way bypass option provide?\u003c\/h4\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eSelect Yes for a factory-installed 3-way system bypass, or No for the standard package without that optional bypass. It allows air to be routed around the dryer for isolation or service. Bypassed air is untreated.\u003c\/p\u003e\n\u003ch4 style=\"font-size:17px;line-height:1.5;font-weight:700;margin:20px 0 6px;\"\u003eWhich pressure rating should I choose?\u003c\/h4\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eThis model includes a 200 PSIG maximum operating pressure rating as standard. There is no separate charge for a 200 PSIG upgrade on this size.\u003c\/p\u003e\n\u003ch4 style=\"font-size:17px;line-height:1.5;font-weight:700;margin:20px 0 6px;\"\u003eWhat power supply is required, and is it made in the USA?\u003c\/h4\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eThe HBS-0200-2 requires 230 VAC \/ 1 Phase \/ 60 Hz. It is made in the USA. Verify the selected equipment nameplate, circuit requirements, and installation instructions before installation.\u003c\/p\u003e\n\u003ch3 style=\"font-size:20px;line-height:1.4;font-weight:700;margin:28px 0 12px;\"\u003eWhy Buy from Compressed Air Advisors Online?\u003c\/h3\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eGet help selecting the dryer for your airflow, pressure, dew point, and operating schedule. Call \u003cstrong\u003e877.247.2381\u003c\/strong\u003e to discuss your application before ordering.\u003c\/p\u003e\n\u003ch3 style=\"font-size:20px;line-height:1.4;font-weight:700;margin:28px 0 12px;\"\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003e\u003cstrong\u003eFree shipping within the contiguous United States.\u003c\/strong\u003e Contact us to coordinate unloading, rigging, liftgate availability, and delivery access. Large units require suitable receiving equipment.\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eFactory-configured and built-to-order equipment is non-returnable. Otherwise eligible returns require an RMA within 14 days, must be new and unused, and are subject to a 25% restocking fee and customer-paid return freight. Our return policy applies.\u003c\/p\u003e\n\u003c\/div\u003e\u003cscript type=\"application\/ld+json\"\u003e{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"What makes the HBS different from other desiccant dryers?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"It uses one desiccant tower with a heater and blower for offline regeneration. Factory-installed pre- and after-filters, only three moving parts, and no moving parts during the drying cycle make it a simple packaged option.\"}},{\"@type\":\"Question\",\"name\":\"Does it supply dried air while regenerating?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"No. The single tower regenerates offline and must cool and repressurize before drying resumes. Plan regeneration during downtime or provide another dry-air source. A bypass passes untreated air and does not replace a second drying tower.\"}},{\"@type\":\"Question\",\"name\":\"How much airflow can the HBS-0200-2 handle?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Rated inlet flow is 200 SCFM at 100 PSIG. Actual selection also depends on inlet temperature, pressure, moisture loading, required dew point, and available time between drying cycles. Contact us to confirm application sizing.\"}},{\"@type\":\"Question\",\"name\":\"What dew point can it achieve?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"The HBS series offers outlet dew points from 0°F to as low as -50°F, depending on operating conditions and application sizing. Do not assume -50°F is guaranteed at every airflow and duty cycle.\"}},{\"@type\":\"Question\",\"name\":\"Are pre-filters and after-filters included?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. Factory-installed pre- and after-filters are included. Maintain the filter elements and desiccant according to Altec AIR instructions. Separate RAD refrigerated dryer filter kits are not required for the standard HBS package.\"}},{\"@type\":\"Question\",\"name\":\"What does the 3-way bypass option provide?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Select Yes for a factory-installed 3-way system bypass, or No for the standard package without that optional bypass. It allows air to be routed around the dryer for isolation or service. Bypassed air is untreated.\"}},{\"@type\":\"Question\",\"name\":\"Which pressure rating should I choose?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"This model includes a 200 PSIG maximum operating pressure rating as standard. There is no separate charge for a 200 PSIG upgrade on this size.\"}},{\"@type\":\"Question\",\"name\":\"What power supply is required, and is it made in the USA?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"The HBS-0200-2 requires 230 VAC \/ 1 Phase \/ 60 Hz. It is made in the USA. Verify the selected equipment nameplate, circuit requirements, and installation instructions before installation.\"}}]}\u003c\/script\u003e","brand":"Altec","offers":[{"title":"No","offer_id":50947268771910,"sku":"HBS-0200-2","price":10218.0,"currency_code":"USD","in_stock":true},{"title":"Yes","offer_id":50947268804678,"sku":"HBS-0200-2-3","price":10764.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0014\/6237\/0374\/files\/altec-air-hbs-series.jpg?v=1793916422","url":"https:\/\/www.compressedairadvisors.com\/products\/altec-air-hbs-0200-2-200-cfm-single-tower-desiccant-air-dryer","provider":"Compressed Air Advisors Online, Inc. ","version":"1.0","type":"link"}