{"product_id":"altec-air-hrl-0130-1-130-cfm-desiccant-air-dryer","title":"Altec AIR HRL-0130-1 130 CFM Heatless Desiccant Air Dryer","description":"\u003cdiv class=\"item-blurb\" style=\"font-size:16px;line-height:1.65;color:inherit;\"\u003e\n\u003ch2 style=\"font-size:22px;line-height:1.35;font-weight:700;margin:0 0 18px;\"\u003eAltec AIR HRL-0130-1 — 130 SCFM Heatless Desiccant Air Dryer\u003c\/h2\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003e\u003cstrong\u003eMade in the USA.\u003c\/strong\u003e The Altec AIR HRL-0130-1 is a twin-tower heatless regenerative desiccant air dryer for industrial compressed air systems requiring a \u003cstrong\u003e-40°F\/-40°C pressure dew point\u003c\/strong\u003e. Factory-installed pre-filters and after-filters, regulated purge flow, and a Pro-Logic controller provide a complete drying package for moisture-sensitive equipment and processes.\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003e\u003cstrong\u003e130 SCFM is the rated inlet flow.\u003c\/strong\u003e At standard rating conditions, approximate regeneration purge is \u003cstrong\u003e19.5 SCFM\u003c\/strong\u003e, leaving approximately \u003cstrong\u003e110.5 SCFM of usable outlet flow\u003c\/strong\u003e. Match the dryer to downstream demand and operating conditions, including the compressed air needed for regeneration.\u003c\/p\u003e\n\u003ch3 style=\"font-size:20px;line-height:1.4;font-weight:700;margin:28px 0 12px;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"font-size:16px;line-height:1.65;list-style-type:disc;padding-left:24px;margin:0 0 20px;\"\u003e\n\u003cli style=\"display:list-item;margin:0 0 8px;\"\u003e\n\u003cstrong\u003eMade in the USA\u003c\/strong\u003e — Altec AIR industrial desiccant drying.\u003c\/li\u003e\n\u003cli style=\"display:list-item;margin:0 0 8px;\"\u003e\n\u003cstrong\u003e130 SCFM rated inlet flow\u003c\/strong\u003e at 100 PSIG and 100°F inlet temperature.\u003c\/li\u003e\n\u003cli style=\"display:list-item;margin:0 0 8px;\"\u003e\n\u003cstrong\u003e-40°F\/-40°C standard pressure dew point\u003c\/strong\u003e — ISO 8573-1 Class 2 for water.\u003c\/li\u003e\n\u003cli style=\"display:list-item;margin:0 0 8px;\"\u003e\n\u003cstrong\u003eFactory-installed pre-filters and after-filters\u003c\/strong\u003e with differential-pressure gauges and pre-filter timer drain.\u003c\/li\u003e\n\u003cli style=\"display:list-item;margin:0 0 8px;\"\u003e\n\u003cstrong\u003eASME \/ CRN approved pressure vessels\u003c\/strong\u003e and ASME safety relief valves.\u003c\/li\u003e\n\u003cli style=\"display:list-item;margin:0 0 8px;\"\u003e\n\u003cstrong\u003eE-Z switching valves\u003c\/strong\u003e designed for long valve life.\u003c\/li\u003e\n\u003cli style=\"display:list-item;margin:0 0 8px;\"\u003e\n\u003cstrong\u003eETL-listed Pro-Logic controller\u003c\/strong\u003e with NEMA 4 enclosure, standby mode, and manual cycle stepping.\u003c\/li\u003e\n\u003cli style=\"display:list-item;margin:0 0 8px;\"\u003e\n\u003cstrong\u003eRegulated purge flow\u003c\/strong\u003e, tower pressure gauges, desiccant fill\/drain ports, and control-line filter\/regulator.\u003c\/li\u003e\n\u003cli style=\"display:list-item;margin:0 0 8px;\"\u003e\n\u003cstrong\u003e1\" NPT inlet and outlet connections\u003c\/strong\u003e; standard 120V single-phase power.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"font-size:20px;line-height:1.4;font-weight:700;margin:28px 0 12px;\"\u003eApplications \u0026amp; Sizing\u003c\/h3\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eA practical choice for manufacturing, instrumentation, pneumatic controls, and industrial processes that need very dry compressed air. The twin-tower design regenerates one desiccant bed while the other dries the air stream. Select equipment for the required dew point and actual airflow rather than compressor horsepower alone.\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eProvide cooled inlet air and effective upstream bulk-water removal. Maintain the supplied filters and drain, and leave sufficient access for valve, filter, and desiccant service. For operating pressures other than 100 PSIG, use the applicable capacity correction and purge setting; do not exceed the selected unit's maximum pressure rating.\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eExplore \u003ca href=\"\/collections\/altec-desiccant-air-dryers\" style=\"color:#0056b3 !important;font-weight:700 !important;text-decoration:underline;\"\u003eAltec AIR desiccant air dryers\u003c\/a\u003e or call \u003cstrong\u003e877.247.2381\u003c\/strong\u003e for sizing assistance.\u003c\/p\u003e\n\u003ch3 style=\"font-size:20px;line-height:1.4;font-weight:700;margin:28px 0 12px;\"\u003eConfigure Your Dryer\u003c\/h3\u003e\n\u003ctable style=\"font-size:16px;line-height:1.5;width:100%;border-collapse:collapse;margin:12px 0 24px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;vertical-align:top;font-weight:600;padding:10px 12px;border-bottom:1px solid #ddd;width:42%;\"\u003eBase Unit\u003c\/th\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;padding:10px 12px;border-bottom:1px solid #ddd;\"\u003eNo 3-way bypass; no outdoor low-ambient kit; 150 PSIG maximum pressure.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;vertical-align:top;font-weight:600;padding:10px 12px;border-bottom:1px solid #ddd;width:42%;\"\u003e3-Way Bypass — Optional\u003c\/th\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;padding:10px 12px;border-bottom:1px solid #ddd;\"\u003eFactory-installed bypass package; select Yes to add. SKU option code: 3.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;vertical-align:top;font-weight:600;padding:10px 12px;border-bottom:1px solid #ddd;width:42%;\"\u003eOutdoor Low Ambient — Optional\u003c\/th\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;padding:10px 12px;border-bottom:1px solid #ddd;\"\u003eFactory-installed outdoor low-ambient package for operation down to -20°F ambient; select Yes to add. SKU option code: L.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;vertical-align:top;font-weight:600;padding:10px 12px;border-bottom:1px solid #ddd;width:42%;\"\u003ePressure Rating\u003c\/th\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;padding:10px 12px;border-bottom:1px solid #ddd;\"\u003eSelect 150 PSIG standard or the optional factory 200 PSIG configuration. The 200-PSIG option adds the SKU suffix -200.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003e\u003cstrong\u003eBuild the combination you need:\u003c\/strong\u003e all three selections can be combined. Choose the 3-way bypass for service flexibility, the outdoor low-ambient kit for cold installations, and the 200-PSIG rating when system pressure requires it. Bypass mode routes air around the drying process and does not maintain the dryer's outlet dew point.\u003c\/p\u003e\n\u003ch3 style=\"font-size:20px;line-height:1.4;font-weight:700;margin:28px 0 12px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"font-size:16px;line-height:1.5;width:100%;border-collapse:collapse;margin:12px 0 24px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;vertical-align:top;font-weight:600;padding:10px 12px;border-bottom:1px solid #ddd;width:42%;\"\u003eBase Manufacturer Part Number\u003c\/th\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;padding:10px 12px;border-bottom:1px solid #ddd;\"\u003eHRL-0130-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;vertical-align:top;font-weight:600;padding:10px 12px;border-bottom:1px solid #ddd;width:42%;\"\u003eDryer Type\u003c\/th\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;padding:10px 12px;border-bottom:1px solid #ddd;\"\u003eTwin-tower heatless regenerative desiccant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;vertical-align:top;font-weight:600;padding:10px 12px;border-bottom:1px solid #ddd;width:42%;\"\u003eRated Inlet Flow\u003c\/th\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;padding:10px 12px;border-bottom:1px solid #ddd;\"\u003e130 SCFM @ 100 PSIG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;vertical-align:top;font-weight:600;padding:10px 12px;border-bottom:1px solid #ddd;width:42%;\"\u003eApproximate Purge Flow\u003c\/th\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;padding:10px 12px;border-bottom:1px solid #ddd;\"\u003e19.5 SCFM at standard rating conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;vertical-align:top;font-weight:600;padding:10px 12px;border-bottom:1px solid #ddd;width:42%;\"\u003eApproximate Usable Outlet Flow\u003c\/th\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;padding:10px 12px;border-bottom:1px solid #ddd;\"\u003e110.5 SCFM at standard rating conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;vertical-align:top;font-weight:600;padding:10px 12px;border-bottom:1px solid #ddd;width:42%;\"\u003eStandard Rating Conditions\u003c\/th\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;padding:10px 12px;border-bottom:1px solid #ddd;\"\u003e100 PSIG inlet pressure, 100°F inlet temperature, -40°F pressure dew point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;vertical-align:top;font-weight:600;padding:10px 12px;border-bottom:1px solid #ddd;width:42%;\"\u003eStandard Pressure Dew Point\u003c\/th\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;padding:10px 12px;border-bottom:1px solid #ddd;\"\u003e-40°F \/ -40°C; ISO 8573-1 Class 2 for water\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;vertical-align:top;font-weight:600;padding:10px 12px;border-bottom:1px solid #ddd;width:42%;\"\u003eMaximum Pressure\u003c\/th\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;padding:10px 12px;border-bottom:1px solid #ddd;\"\u003e150 PSIG standard; 200 PSIG only when selected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;vertical-align:top;font-weight:600;padding:10px 12px;border-bottom:1px solid #ddd;width:42%;\"\u003eMaximum Inlet Temperature\u003c\/th\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;padding:10px 12px;border-bottom:1px solid #ddd;\"\u003e120°F \/ 49°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;vertical-align:top;font-weight:600;padding:10px 12px;border-bottom:1px solid #ddd;width:42%;\"\u003eElectrical Supply\u003c\/th\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;padding:10px 12px;border-bottom:1px solid #ddd;\"\u003e120 VAC \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;vertical-align:top;font-weight:600;padding:10px 12px;border-bottom:1px solid #ddd;width:42%;\"\u003eController \/ Enclosure\u003c\/th\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;padding:10px 12px;border-bottom:1px solid #ddd;\"\u003ePro-Logic \/ NEMA 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;vertical-align:top;font-weight:600;padding:10px 12px;border-bottom:1px solid #ddd;width:42%;\"\u003eInlet \/ Outlet Connections\u003c\/th\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;padding:10px 12px;border-bottom:1px solid #ddd;\"\u003e1\" NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;vertical-align:top;font-weight:600;padding:10px 12px;border-bottom:1px solid #ddd;width:42%;\"\u003eBase Dimensions (H × W × D)\u003c\/th\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;padding:10px 12px;border-bottom:1px solid #ddd;\"\u003e79\" × 27\" × 30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;vertical-align:top;font-weight:600;padding:10px 12px;border-bottom:1px solid #ddd;width:42%;\"\u003eApproximate Base Weight\u003c\/th\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;padding:10px 12px;border-bottom:1px solid #ddd;\"\u003e465 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eDimensions and weights shown are for the base unit. Selected options can change the footprint, weight, and installation requirements. Confirm final configuration dimensions before planning piping, access, or placement.\u003c\/p\u003e\n\u003ch3 style=\"font-size:20px;line-height:1.4;font-weight:700;margin:28px 0 12px;\"\u003eWhat's Included\u003c\/h3\u003e\n\u003cul style=\"font-size:16px;line-height:1.65;list-style-type:disc;padding-left:24px;margin:0 0 20px;\"\u003e\n\u003cli style=\"display:list-item;margin:0 0 8px;\"\u003eHRL-0130-1 dryer in the selected configuration.\u003c\/li\u003e\n\u003cli style=\"display:list-item;margin:0 0 8px;\"\u003eFactory-installed pre-filters and after-filters, filter differential-pressure gauges, and pre-filter timer drain.\u003c\/li\u003e\n\u003cli style=\"display:list-item;margin:0 0 8px;\"\u003eTower pressure gauges, controller, regulated purge system, mufflers, and safety relief valves.\u003c\/li\u003e\n\u003cli style=\"display:list-item;margin:0 0 8px;\"\u003eFactory-installed 3-way bypass, outdoor low-ambient package, and\/or 200-PSIG pressure upgrade only when selected.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eSite piping, electrical installation, condensate handling, and other installation materials are separate. Dew point demand control and additional factory options are available by quotation.\u003c\/p\u003e\n\u003ch3 style=\"font-size:20px;line-height:1.4;font-weight:700;margin:28px 0 12px;\"\u003eLead Time\u003c\/h3\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eThese dryers and factory-option packages are configuration dependent. Contact us for current availability and an estimated ship date, especially when your project has a required delivery date.\u003c\/p\u003e\n\u003ch3 style=\"font-size:20px;line-height:1.4;font-weight:700;margin:28px 0 12px;\"\u003eWarranty\u003c\/h3\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003e\u003cstrong\u003eTwo-year limited manufacturer warranty from the date of shipment.\u003c\/strong\u003e First-year coverage includes qualifying replacement parts and labor under the manufacturer's warranty schedule. Second-year coverage is replacement parts only. Manufacturer terms, exclusions, installation requirements, and claim procedures apply.\u003c\/p\u003e\n\u003ch3 style=\"font-size:20px;line-height:1.4;font-weight:700;margin:28px 0 12px;\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4 style=\"font-size:17px;line-height:1.5;font-weight:700;margin:20px 0 6px;\"\u003eIs the 130 SCFM rating inlet flow or delivered outlet flow?\u003c\/h4\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eIt is inlet flow at 100 PSIG inlet pressure, 100°F inlet temperature, and a -40°F pressure dew point. Approximate purge consumption is 19.5 SCFM, leaving approximately 110.5 SCFM for downstream use at those conditions. Account for regeneration air when checking compressor capacity.\u003c\/p\u003e\n\u003ch4 style=\"font-size:17px;line-height:1.5;font-weight:700;margin:20px 0 6px;\"\u003eAre pre-filters and after-filters included?\u003c\/h4\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eYes. Factory-installed pre-filtration and after-filtration are included, along with filter differential-pressure gauges and a timer drain on the pre-filter. Maintain filters and drains to help protect the desiccant and downstream equipment.\u003c\/p\u003e\n\u003ch4 style=\"font-size:17px;line-height:1.5;font-weight:700;margin:20px 0 6px;\"\u003eWhat does the 3-way bypass option do?\u003c\/h4\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eThe factory-installed 3-way bypass lets airflow be routed around the dryer for service or isolation. Air flowing through the bypass is not being dried by the dryer; assess downstream moisture requirements before using bypass mode.\u003c\/p\u003e\n\u003ch4 style=\"font-size:17px;line-height:1.5;font-weight:700;margin:20px 0 6px;\"\u003eDo I need the outdoor low-ambient kit?\u003c\/h4\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eSelect this option for applications requiring the factory outdoor low-ambient package, rated down to -20°F ambient. The standard base unit does not include this package. Confirm site conditions and installation requirements before ordering.\u003c\/p\u003e\n\u003ch4 style=\"font-size:17px;line-height:1.5;font-weight:700;margin:20px 0 6px;\"\u003eCan the base unit operate at 200 PSIG?\u003c\/h4\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eNo. The standard unit is rated to 150 PSIG maximum. Select the 200 PSIG pressure-rating option for a factory-configured 200-PSIG unit. This option changes the maximum pressure rating; the advertised airflow remains the 100-PSIG inlet rating.\u003c\/p\u003e\n\u003ch4 style=\"font-size:17px;line-height:1.5;font-weight:700;margin:20px 0 6px;\"\u003eCan I combine all three options?\u003c\/h4\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eYes. Choose the bypass, outdoor low-ambient package, and pressure rating independently. Each combination has its own SKU and price. The base unit is No bypass, No outdoor low-ambient kit, and 150 PSIG standard pressure rating.\u003c\/p\u003e\n\u003ch4 style=\"font-size:17px;line-height:1.5;font-weight:700;margin:20px 0 6px;\"\u003eWhat power supply and dew point does this dryer use?\u003c\/h4\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eStandard power is 120 VAC, single-phase, 60 Hz. The standard outlet pressure dew point is -40°F\/-40°C, corresponding to ISO 8573-1 Class 2 for water. Confirm circuit requirements against the selected equipment's nameplate and installation instructions.\u003c\/p\u003e\n\u003ch4 style=\"font-size:17px;line-height:1.5;font-weight:700;margin:20px 0 6px;\"\u003eHow should I size the dryer for my system?\u003c\/h4\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eUse actual inlet pressure, inlet temperature, required pressure dew point, and downstream airflow demand. Apply the appropriate capacity corrections and allow for purge consumption. The 120°F maximum inlet temperature is an operating limit, not the full-capacity rating condition. Call 877.247.2381 for selection assistance.\u003c\/p\u003e\n\u003ch3 style=\"font-size:20px;line-height:1.4;font-weight:700;margin:28px 0 12px;\"\u003eWhy Buy From Compressed Air Advisors Online?\u003c\/h3\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eOur team helps customers nationwide select compressed air dryers, filtration, and accessories for their actual application. Call \u003cstrong\u003e877.247.2381\u003c\/strong\u003e for help matching flow, dew point, pressure, and installation conditions.\u003c\/p\u003e\n\u003ch3 style=\"font-size:20px;line-height:1.4;font-weight:700;margin:28px 0 12px;\"\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003e\u003cstrong\u003eFree shipping within the contiguous United States.\u003c\/strong\u003e Contact us to coordinate unloading, rigging, liftgate availability, or special delivery needs. Large units require suitable receiving equipment and site access.\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eFactory-configured and built-to-order equipment is non-returnable. Any otherwise eligible return requires an RMA within 14 days, must be new and unused, and is subject to a 25% restocking fee and customer-paid return freight. Our return policy applies.\u003c\/p\u003e\n\u003c\/div\u003e\u003cscript type=\"application\/ld+json\"\u003e{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"Is the 130 SCFM rating inlet flow or delivered outlet flow?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"It is inlet flow at 100 PSIG inlet pressure, 100°F inlet temperature, and a -40°F pressure dew point. Approximate purge consumption is 19.5 SCFM, leaving approximately 110.5 SCFM for downstream use at those conditions. Account for regeneration air when checking compressor capacity.\"}},{\"@type\":\"Question\",\"name\":\"Are pre-filters and after-filters included?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. Factory-installed pre-filtration and after-filtration are included, along with filter differential-pressure gauges and a timer drain on the pre-filter. Maintain filters and drains to help protect the desiccant and downstream equipment.\"}},{\"@type\":\"Question\",\"name\":\"What does the 3-way bypass option do?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"The factory-installed 3-way bypass lets airflow be routed around the dryer for service or isolation. Air flowing through the bypass is not being dried by the dryer; assess downstream moisture requirements before using bypass mode.\"}},{\"@type\":\"Question\",\"name\":\"Do I need the outdoor low-ambient kit?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Select this option for applications requiring the factory outdoor low-ambient package, rated down to -20°F ambient. The standard base unit does not include this package. Confirm site conditions and installation requirements before ordering.\"}},{\"@type\":\"Question\",\"name\":\"Can the base unit operate at 200 PSIG?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"No. The standard unit is rated to 150 PSIG maximum. Select the 200 PSIG pressure-rating option for a factory-configured 200-PSIG unit. This option changes the maximum pressure rating; the advertised airflow remains the 100-PSIG inlet rating.\"}},{\"@type\":\"Question\",\"name\":\"Can I combine all three options?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. Choose the bypass, outdoor low-ambient package, and pressure rating independently. Each combination has its own SKU and price. The base unit is No bypass, No outdoor low-ambient kit, and 150 PSIG standard pressure rating.\"}},{\"@type\":\"Question\",\"name\":\"What power supply and dew point does this dryer use?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Standard power is 120 VAC, single-phase, 60 Hz. The standard outlet pressure dew point is -40°F\/-40°C, corresponding to ISO 8573-1 Class 2 for water. Confirm circuit requirements against the selected equipment's nameplate and installation instructions.\"}},{\"@type\":\"Question\",\"name\":\"How should I size the dryer for my system?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Use actual inlet pressure, inlet temperature, required pressure dew point, and downstream airflow demand. Apply the appropriate capacity corrections and allow for purge consumption. The 120°F maximum inlet temperature is an operating limit, not the full-capacity rating condition. Call 877.247.2381 for selection assistance.\"}}]}\u003c\/script\u003e","brand":"Altec","offers":[{"title":"No \/ No \/ 150 PSIG","offer_id":50939813888070,"sku":"HRL-0130-1","price":10479.0,"currency_code":"USD","in_stock":true},{"title":"No \/ No \/ 200 PSIG","offer_id":50939813920838,"sku":"HRL-0130-1-200","price":11064.0,"currency_code":"USD","in_stock":true},{"title":"No \/ Yes \/ 150 PSIG","offer_id":50939813953606,"sku":"HRL-0130-1-L","price":14347.0,"currency_code":"USD","in_stock":true},{"title":"No \/ Yes \/ 200 PSIG","offer_id":50939813986374,"sku":"HRL-0130-1-L-200","price":14933.0,"currency_code":"USD","in_stock":true},{"title":"Yes \/ No \/ 150 PSIG","offer_id":50939814019142,"sku":"HRL-0130-1-3","price":10731.0,"currency_code":"USD","in_stock":true},{"title":"Yes \/ No \/ 200 PSIG","offer_id":50939814051910,"sku":"HRL-0130-1-3-200","price":11317.0,"currency_code":"USD","in_stock":true},{"title":"Yes \/ Yes \/ 150 PSIG","offer_id":50939814084678,"sku":"HRL-0130-1-3L","price":14600.0,"currency_code":"USD","in_stock":true},{"title":"Yes \/ Yes \/ 200 PSIG","offer_id":50939814117446,"sku":"HRL-0130-1-3L-200","price":15186.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0014\/6237\/0374\/files\/HRLSeries.jpg?v=1771446896","url":"https:\/\/www.compressedairadvisors.com\/products\/altec-air-hrl-0130-1-130-cfm-desiccant-air-dryer","provider":"Compressed Air Advisors Online, Inc. ","version":"1.0","type":"link"}