{"product_id":"chicago-pneumatic-cpxht25-high-temperature-dryer-4102001900","title":"Chicago Pneumatic CPXHT25 (H1) 25 SCFM High-Temperature Refrigerated Air Dryer, 3\/4\" NPT, 115V\/1Ph - PN 4102001900","description":"\u003ch1 class=\"PDq2pG_selectionAnchorContainer\"\u003eChicago Pneumatic CPXHT25 (H1) 25 SCFM High-Temperature Refrigerated Air Dryer, 3\/4\" NPT, 115V\/1Ph - PN 4102001900\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003ch2\u003eHigh-Temperature Moisture Removal for Reciprocating Air Compressor Systems\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eChicago Pneumatic CPXHT25 High-Temperature Refrigerated Air Dryer, part number 4102001900\u003c\/strong\u003e, is designed to remove moisture from compressed air systems operating with elevated inlet-air temperatures.\u003c\/p\u003e\n\u003cp\u003eRated for \u003cstrong\u003e25 SCFM at 100 PSIG\u003c\/strong\u003e, the CPXHT25 can accept compressed-air inlet temperatures up to \u003cstrong\u003e180°F\u003c\/strong\u003e. This allows it to be installed with many reciprocating air compressor systems without requiring a separate aftercooler.\u003c\/p\u003e\n\u003cp\u003eThe CPXHT25 combines a refrigerated air dryer, moisture separator, and electronic condensate drain in one compact package. As the compressed air is cooled, moisture condenses and is separated from the airflow before being discharged automatically.\u003c\/p\u003e\n\u003cp\u003eWith a \u003cstrong\u003e50°F pressure dew point\u003c\/strong\u003e, the dryer helps reduce water in compressed-air piping while protecting pneumatic tools, cylinders, paint equipment, production machinery, and finished products from moisture-related problems.\u003c\/p\u003e\n\u003cp\u003eThe CPXHT25 operates on standard \u003cstrong\u003e115-volt single-phase power\u003c\/strong\u003e and uses \u003cstrong\u003e3\/4-inch NPT inlet and outlet connections\u003c\/strong\u003e, simplifying installation in automotive shops, maintenance facilities, woodworking operations, and other commercial compressed-air applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer Part Number: 4102001900\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eKey Features and Benefits\u003c\/h2\u003e\n\u003ch3\u003eHandles Inlet Temperatures Up to 180°F\u003c\/h3\u003e\n\u003cp\u003eThe CPXHT25 is specifically engineered for high-temperature compressed air produced by reciprocating air compressors.\u003c\/p\u003e\n\u003cp\u003eIts ability to handle inlet temperatures up to \u003cstrong\u003e180°F\u003c\/strong\u003e can eliminate the need for a separate aftercooler in properly sized applications.\u003c\/p\u003e\n\u003ch3\u003e25 SCFM Rated Capacity\u003c\/h3\u003e\n\u003cp\u003eThe dryer is rated for \u003cstrong\u003e25 SCFM at 100 PSIG\u003c\/strong\u003e, making it a strong match for many 5 HP and 7.5 HP reciprocating air compressor systems.\u003c\/p\u003e\n\u003cp\u003eActual dryer capacity depends on operating pressure, ambient temperature, inlet-air temperature, and airflow demand.\u003c\/p\u003e\n\u003ch3\u003e50°F Pressure Dew Point\u003c\/h3\u003e\n\u003cp\u003eThe CPXHT25 provides a pressure dew point of approximately \u003cstrong\u003e50°F ± 2°F\u003c\/strong\u003e, helping reduce liquid water formation in downstream piping and equipment.\u003c\/p\u003e\n\u003ch3\u003eIntegrated Moisture Separator\u003c\/h3\u003e\n\u003cp\u003eThe built-in moisture separator removes condensed water from the compressed-air stream after cooling.\u003c\/p\u003e\n\u003ch3\u003eElectronic Condensate Drain\u003c\/h3\u003e\n\u003cp\u003eAn integrated electronic water drain automatically discharges collected condensate, reducing the need for manual draining and helping maintain dependable dryer performance.\u003c\/p\u003e\n\u003ch3\u003eStainless Steel and Copper Heat Exchanger\u003c\/h3\u003e\n\u003cp\u003eThe stainless steel and copper heat exchanger provides dependable thermal transfer while supporting long-term performance in demanding compressed-air applications.\u003c\/p\u003e\n\u003ch3\u003e115V Single-Phase Power\u003c\/h3\u003e\n\u003cp\u003eThe CPXHT25 operates on \u003cstrong\u003e115V single-phase, 60 Hz power\u003c\/strong\u003e, eliminating the need for specialized three-phase electrical service.\u003c\/p\u003e\n\u003ch3\u003eCompact Footprint\u003c\/h3\u003e\n\u003cp\u003eMeasuring approximately \u003cstrong\u003e14 inches long, 15 inches wide, and 18 inches high\u003c\/strong\u003e, the CPXHT25 provides high-temperature drying capability without consuming excessive floor space.\u003c\/p\u003e\n\u003ch3\u003eQuiet Enclosed Design\u003c\/h3\u003e\n\u003cp\u003eThe dryer’s internal layout and enclosed cabinet help reduce operating noise, making it suitable for installation near active work areas when proper ventilation is provided.\u003c\/p\u003e\n\u003ch3\u003eMaximum Pressure of 232 PSIG\u003c\/h3\u003e\n\u003cp\u003eThe CPXHT25 is rated for compressed-air systems operating at pressures up to \u003cstrong\u003e232 PSIG\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eHelps Protect Pneumatic Equipment\u003c\/h3\u003e\n\u003cp\u003eRemoving moisture from compressed air helps protect:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePneumatic tools\u003c\/li\u003e\n\u003cli\u003eAir cylinders\u003c\/li\u003e\n\u003cli\u003eImpact tools\u003c\/li\u003e\n\u003cli\u003eTire-service equipment\u003c\/li\u003e\n\u003cli\u003ePaint equipment\u003c\/li\u003e\n\u003cli\u003eRegulators and control valves\u003c\/li\u003e\n\u003cli\u003eProduction machinery\u003c\/li\u003e\n\u003cli\u003eCompressed-air piping\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHelps Improve Finished Product Quality\u003c\/h3\u003e\n\u003cp\u003eDryer air can help reduce moisture-related defects in paint, finishing, fabrication, assembly, and production applications.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eStandard Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e25 SCFM rated airflow at 100 PSIG\u003c\/li\u003e\n\u003cli\u003eMaximum inlet-air temperature of 180°F\u003c\/li\u003e\n\u003cli\u003e50°F pressure dew point, ±2°F\u003c\/li\u003e\n\u003cli\u003e232 PSIG maximum operating pressure\u003c\/li\u003e\n\u003cli\u003e115V single-phase electrical power\u003c\/li\u003e\n\u003cli\u003e60 Hz operation\u003c\/li\u003e\n\u003cli\u003e3\/4-inch NPT air connections\u003c\/li\u003e\n\u003cli\u003eStainless steel and copper heat exchanger\u003c\/li\u003e\n\u003cli\u003eIntegrated refrigerated air dryer\u003c\/li\u003e\n\u003cli\u003eBuilt-in moisture separator\u003c\/li\u003e\n\u003cli\u003eElectronic condensate drain\u003c\/li\u003e\n\u003cli\u003eCompact enclosed design\u003c\/li\u003e\n\u003cli\u003eQuiet operation\u003c\/li\u003e\n\u003cli\u003eAir-cooled refrigeration system\u003c\/li\u003e\n\u003cli\u003eR-134a refrigerant\u003c\/li\u003e\n\u003cli\u003eDesigned for high-temperature compressor discharge air\u003c\/li\u003e\n\u003cli\u003eSuitable for many 5 HP and 7.5 HP reciprocating compressors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eChicago Pneumatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCPXHT25 (H1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer Part Number\u003c\/td\u003e\n\u003ctd\u003e4102001900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDryer Type\u003c\/td\u003e\n\u003ctd\u003eHigh-temperature refrigerated air dryer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Airflow\u003c\/td\u003e\n\u003ctd\u003e25 SCFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Flow Conditions\u003c\/td\u003e\n\u003ctd\u003e100 PSIG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Dew Point\u003c\/td\u003e\n\u003ctd\u003e50°F ± 2°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Inlet-Air Temperature\u003c\/td\u003e\n\u003ctd\u003e180°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Ambient Temperature\u003c\/td\u003e\n\u003ctd\u003e113°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Ambient Temperature\u003c\/td\u003e\n\u003ctd\u003e41°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Working Pressure\u003c\/td\u003e\n\u003ctd\u003e232 PSIG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Inlet Connection\u003c\/td\u003e\n\u003ctd\u003e3\/4-inch NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Outlet Connection\u003c\/td\u003e\n\u003ctd\u003e3\/4-inch NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e115V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eSingle phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat Exchanger\u003c\/td\u003e\n\u003ctd\u003eStainless steel and copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMoisture Separator\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectronic Condensate Drain\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-134a\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproximate Length\u003c\/td\u003e\n\u003ctd\u003e14 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproximate Width\u003c\/td\u003e\n\u003ctd\u003e15 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproximate Height\u003c\/td\u003e\n\u003ctd\u003e18 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproximate Weight\u003c\/td\u003e\n\u003ctd\u003e57 pounds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003ch2\u003eRecommended Applications\u003c\/h2\u003e\n\u003cp\u003eThe Chicago Pneumatic CPXHT25 is well suited for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAutomotive repair shops\u003c\/li\u003e\n\u003cli\u003eCollision repair and body shops\u003c\/li\u003e\n\u003cli\u003eTire-service facilities\u003c\/li\u003e\n\u003cli\u003eFleet-maintenance departments\u003c\/li\u003e\n\u003cli\u003eWoodworking shops\u003c\/li\u003e\n\u003cli\u003eCabinet shops\u003c\/li\u003e\n\u003cli\u003eSmall fabrication facilities\u003c\/li\u003e\n\u003cli\u003eMaintenance departments\u003c\/li\u003e\n\u003cli\u003eLight manufacturing\u003c\/li\u003e\n\u003cli\u003ePaint and finishing operations\u003c\/li\u003e\n\u003cli\u003ePneumatic assembly equipment\u003c\/li\u003e\n\u003cli\u003eAir-operated tools\u003c\/li\u003e\n\u003cli\u003eCommercial garages\u003c\/li\u003e\n\u003cli\u003eSmall production facilities\u003c\/li\u003e\n\u003cli\u003eReciprocating air compressor systems\u003c\/li\u003e\n\u003cli\u003e5 HP and 7.5 HP compressor applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe dryer should be sized according to the compressor’s actual airflow, operating pressure, inlet-air temperature, and maximum ambient temperature.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eWhy Choose a High-Temperature Refrigerated Air Dryer?\u003c\/h2\u003e\n\u003cp\u003eCompressed air leaving a reciprocating compressor can be extremely hot. A conventional refrigerated dryer may not be designed to accept that elevated temperature without a separate aftercooler.\u003c\/p\u003e\n\u003cp\u003eThe CPXHT25 is engineered to accept inlet temperatures up to \u003cstrong\u003e180°F\u003c\/strong\u003e, making it particularly useful for piston compressor installations.\u003c\/p\u003e\n\u003cp\u003ePotential advantages include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMay eliminate the need for a separate aftercooler\u003c\/li\u003e\n\u003cli\u003eReduces installation complexity\u003c\/li\u003e\n\u003cli\u003eSaves valuable floor space\u003c\/li\u003e\n\u003cli\u003eReduces external piping requirements\u003c\/li\u003e\n\u003cli\u003eRemoves condensed moisture automatically\u003c\/li\u003e\n\u003cli\u003eHelps protect downstream equipment\u003c\/li\u003e\n\u003cli\u003eReduces water accumulation in air lines\u003c\/li\u003e\n\u003cli\u003eHelps reduce manual air-line purging\u003c\/li\u003e\n\u003cli\u003eSupports more consistent compressed-air quality\u003c\/li\u003e\n\u003cli\u003eHelps reduce moisture-related downtime\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eBenefits of Dry Compressed Air\u003c\/h2\u003e\n\u003cp\u003eAtmospheric air naturally contains water vapor. When air is compressed, that moisture becomes concentrated. As the compressed air cools inside the receiver tank and piping system, the moisture can condense into liquid water.\u003c\/p\u003e\n\u003cp\u003eExcessive moisture can contribute to:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInternal corrosion\u003c\/li\u003e\n\u003cli\u003eDamaged pneumatic tools\u003c\/li\u003e\n\u003cli\u003eSticking air cylinders\u003c\/li\u003e\n\u003cli\u003eRust inside compressed-air piping\u003c\/li\u003e\n\u003cli\u003eContaminated paint finishes\u003c\/li\u003e\n\u003cli\u003eFisheye defects\u003c\/li\u003e\n\u003cli\u003eIncreased equipment maintenance\u003c\/li\u003e\n\u003cli\u003eReduced production quality\u003c\/li\u003e\n\u003cli\u003eFrozen exterior air lines\u003c\/li\u003e\n\u003cli\u003eUnplanned downtime\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe CPXHT25 cools the compressed air, separates condensed moisture, and automatically discharges the collected water.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eAir Treatment Recommendations\u003c\/h2\u003e\n\u003cp\u003eA refrigerated dryer primarily removes water vapor and condensed moisture. Some applications may require additional air treatment for particulate contamination, oil aerosols, odors, or other contaminants.\u003c\/p\u003e\n\u003cp\u003eDepending on the application, the compressed-air system may also require:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAutomatic receiver-tank drain\u003c\/li\u003e\n\u003cli\u003eGeneral-purpose particulate filter\u003c\/li\u003e\n\u003cli\u003eHigh-efficiency coalescing filter\u003c\/li\u003e\n\u003cli\u003eActivated-carbon filter\u003c\/li\u003e\n\u003cli\u003ePressure regulator\u003c\/li\u003e\n\u003cli\u003eOil-water separator\u003c\/li\u003e\n\u003cli\u003ePoint-of-use air treatment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003ePaint spraying and sensitive production applications may require additional treatment beyond the refrigerated air dryer.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eInstallation Considerations\u003c\/h2\u003e\n\u003cp\u003eThe CPXHT25 should be installed indoors in a clean, well-ventilated location with adequate space for inspection and maintenance.\u003c\/p\u003e\n\u003cp\u003eBefore installation:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eConfirm that system airflow does not exceed the dryer’s rated capacity.\u003c\/li\u003e\n\u003cli\u003eVerify that the dryer is suitable for the actual inlet-air temperature.\u003c\/li\u003e\n\u003cli\u003eConfirm that operating pressure does not exceed 232 PSIG.\u003c\/li\u003e\n\u003cli\u003eConfirm that ambient temperature remains between 41°F and 113°F.\u003c\/li\u003e\n\u003cli\u003eProvide a 115V single-phase, 60 Hz electrical supply.\u003c\/li\u003e\n\u003cli\u003eVerify that the electrical circuit meets the dryer’s nameplate requirements.\u003c\/li\u003e\n\u003cli\u003eUse properly sized 3\/4-inch compressed-air piping.\u003c\/li\u003e\n\u003cli\u003eConfirm the correct compressed-air flow direction.\u003c\/li\u003e\n\u003cli\u003eKeep the condenser and ventilation openings clear.\u003c\/li\u003e\n\u003cli\u003ePrevent heated exhaust air from recirculating into the dryer.\u003c\/li\u003e\n\u003cli\u003eRoute the electronic drain discharge to an approved condensate collection or treatment system.\u003c\/li\u003e\n\u003cli\u003eProvide isolation valves to simplify future service.\u003c\/li\u003e\n\u003cli\u003eAvoid placing unnecessary restrictions in the inlet or outlet piping.\u003c\/li\u003e\n\u003cli\u003eMaintain the manufacturer’s recommended service clearances.\u003c\/li\u003e\n\u003cli\u003eCheck the compressed-air system for leaks after installation.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eInstallation should be completed according to the supplied operating instructions and all applicable electrical, plumbing, and safety codes.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eRoutine Maintenance\u003c\/h2\u003e\n\u003cp\u003eRoutine inspection helps maintain moisture removal, cooling performance, and dependable operation.\u003c\/p\u003e\n\u003cp\u003eTypical maintenance includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVerify that the electronic condensate drain is operating.\u003c\/li\u003e\n\u003cli\u003eInspect the drain discharge line for restrictions.\u003c\/li\u003e\n\u003cli\u003eKeep the condenser and ventilation openings clean.\u003c\/li\u003e\n\u003cli\u003eRemove accumulated dust and debris from cooling surfaces.\u003c\/li\u003e\n\u003cli\u003eCheck the dryer for unusual noise or vibration.\u003c\/li\u003e\n\u003cli\u003eInspect compressed-air fittings for leaks.\u003c\/li\u003e\n\u003cli\u003eVerify that inlet temperature remains within the rated limit.\u003c\/li\u003e\n\u003cli\u003eConfirm that ambient temperature remains within the allowable range.\u003c\/li\u003e\n\u003cli\u003eInspect the electrical cord and connections.\u003c\/li\u003e\n\u003cli\u003eCheck for excessive pressure drop through the dryer.\u003c\/li\u003e\n\u003cli\u003eFollow the maintenance instructions supplied with the unit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eMaintenance frequency may vary depending on operating hours, dust levels, ambient temperature, humidity, and compressor operating conditions.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eBasic Troubleshooting\u003c\/h2\u003e\n\u003ch3\u003eWater Is Present Downstream\u003c\/h3\u003e\n\u003cp\u003eCheck the electronic drain, drain discharge line, inlet temperature, airflow demand, ambient temperature, operating pressure, and dryer ventilation.\u003c\/p\u003e\n\u003cp\u003eThe dryer may be undersized if actual operating conditions exceed its rated capacity.\u003c\/p\u003e\n\u003ch3\u003eElectronic Drain Does Not Discharge\u003c\/h3\u003e\n\u003cp\u003eCheck the drain’s electrical connection, timer operation, discharge tubing, isolation valve, and condensate outlet for blockage.\u003c\/p\u003e\n\u003ch3\u003eDryer Does Not Start\u003c\/h3\u003e\n\u003cp\u003eCheck the electrical outlet, circuit protection, power cord, dryer switch, and incoming voltage.\u003c\/p\u003e\n\u003ch3\u003eDryer Runs but Does Not Remove Moisture\u003c\/h3\u003e\n\u003cp\u003eVerify that the refrigeration system is operating, the condenser is clean, the drain is functioning, and inlet conditions remain within the dryer’s ratings.\u003c\/p\u003e\n\u003ch3\u003eExcessive Pressure Drop\u003c\/h3\u003e\n\u003cp\u003eInspect the compressed-air piping, valves, fittings, heat exchanger, and downstream air-treatment components for restrictions.\u003c\/p\u003e\n\u003ch3\u003eDryer Shuts Down or Runs Hot\u003c\/h3\u003e\n\u003cp\u003eCheck ambient temperature, ventilation clearance, condenser cleanliness, and whether heated exhaust air is recirculating into the unit.\u003c\/p\u003e\n\u003ch3\u003eExcessive Condensate in the Air System\u003c\/h3\u003e\n\u003cp\u003eConfirm that the receiver tank is being drained and that the dryer is installed and sized correctly for the compressor’s airflow and discharge temperature.\u003c\/p\u003e\n\u003cp\u003eRefrigeration-system repairs, electrical repairs, internal pressure-system repairs, and major service should be completed by qualified personnel.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eFrequently Asked Questions\u003c\/h1\u003e\n\u003ch2\u003eWhat is the rated capacity of the CPXHT25?\u003c\/h2\u003e\n\u003cp\u003eThe CPXHT25 is rated for \u003cstrong\u003e25 SCFM at 100 PSIG\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat is the manufacturer part number?\u003c\/h2\u003e\n\u003cp\u003eThe manufacturer part number is \u003cstrong\u003e4102001900\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat makes this a high-temperature dryer?\u003c\/h2\u003e\n\u003cp\u003eThe CPXHT25 can accept compressed-air inlet temperatures up to \u003cstrong\u003e180°F\u003c\/strong\u003e, allowing it to work with many reciprocating compressor systems without a separate aftercooler.\u003c\/p\u003e\n\u003ch2\u003eWhat pressure dew point does it provide?\u003c\/h2\u003e\n\u003cp\u003eThe CPXHT25 provides a pressure dew point of approximately \u003cstrong\u003e50°F ± 2°F\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eDoes the dryer include a moisture separator?\u003c\/h2\u003e\n\u003cp\u003eYes. The CPXHT25 includes an integrated moisture separator.\u003c\/p\u003e\n\u003ch2\u003eDoes it include an automatic condensate drain?\u003c\/h2\u003e\n\u003cp\u003eYes. The dryer includes an electronic condensate drain that automatically discharges collected moisture.\u003c\/p\u003e\n\u003ch2\u003eWhat electrical service is required?\u003c\/h2\u003e\n\u003cp\u003eThe CPXHT25 requires \u003cstrong\u003e115V single-phase, 60 Hz electrical power\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat size are the air connections?\u003c\/h2\u003e\n\u003cp\u003eThe dryer uses \u003cstrong\u003e3\/4-inch NPT inlet and outlet connections\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat is the maximum operating pressure?\u003c\/h2\u003e\n\u003cp\u003eThe maximum working pressure is \u003cstrong\u003e232 PSIG\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat is the allowable ambient temperature range?\u003c\/h2\u003e\n\u003cp\u003eThe dryer is designed for ambient temperatures between \u003cstrong\u003e41°F and 113°F\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat refrigerant does the CPXHT25 use?\u003c\/h2\u003e\n\u003cp\u003eThe CPXHT25 uses \u003cstrong\u003eR-134a refrigerant\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eDoes this dryer remove oil?\u003c\/h2\u003e\n\u003cp\u003eThe refrigerated dryer primarily removes moisture. Additional coalescing filtration may be needed to remove fine oil aerosols.\u003c\/p\u003e\n\u003ch2\u003eIs this dryer suitable for a 5 HP air compressor?\u003c\/h2\u003e\n\u003cp\u003eYes. It is commonly paired with properly sized 5 HP reciprocating air compressors.\u003c\/p\u003e\n\u003ch2\u003eIs it suitable for a 7.5 HP air compressor?\u003c\/h2\u003e\n\u003cp\u003eIt can be suitable for a 7.5 HP compressor when the compressor’s actual output and operating conditions remain within the dryer’s rated capacity.\u003c\/p\u003e\n\u003ch2\u003eDoes the dryer replace an aftercooler?\u003c\/h2\u003e\n\u003cp\u003eIts high-temperature design can eliminate the need for a separate aftercooler in properly sized applications with inlet temperatures up to 180°F.\u003c\/p\u003e\n\u003ch2\u003eCan this dryer be used for automotive painting?\u003c\/h2\u003e\n\u003cp\u003eYes, provided it is properly sized. Paint applications may also require coalescing and point-of-use air treatment depending on the required finish quality.\u003c\/p\u003e\n\u003ch2\u003eWhere should the condensate drain discharge be routed?\u003c\/h2\u003e\n\u003cp\u003eCondensate should be routed to an appropriate collection or oil-water separation system according to applicable regulations.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eWhy Buy from Compressed Air Advisors Online?\u003c\/h2\u003e\n\u003cp\u003eCompressed Air Advisors Online provides knowledgeable compressed-air equipment selection, system guidance, premium industrial products, and nationwide delivery.\u003c\/p\u003e\n\u003cp\u003eOur team can help determine whether the Chicago Pneumatic CPXHT25 provides the correct capacity, inlet-temperature rating, operating pressure, connections, and electrical configuration for your compressed-air system.\u003c\/p\u003e\n\u003cp\u003eWhen you need dependable air-treatment equipment backed by practical compressed-air knowledge, Compressed Air Advisors Online is your compressed-air partner.\u003c\/p\u003e","brand":"Chicago Pneumatic","offers":[{"title":"Default Title","offer_id":39890567135302,"sku":"4102001900","price":2388.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0014\/6237\/0374\/products\/cpxht25.jpg?v=1646424665","url":"https:\/\/www.compressedairadvisors.com\/products\/chicago-pneumatic-cpxht25-high-temperature-dryer-4102001900","provider":"Compressed Air Advisors Online, Inc. ","version":"1.0","type":"link"}