{"product_id":"chicago-pneumatic-cpxht50-h2-50-scfm-high-temperature-refrigerated-air-dryer-1-npt-115v-1ph-pn-4102003869-copy","title":"Chicago Pneumatic CPXHT100 (H4) 100 SCFM High-Temperature Refrigerated Air Dryer, 3\/4\" NPT, 115V\/1Ph - PN 4102003871","description":"\u003ch1\u003eChicago Pneumatic CPXHT100 (H4) 100 SCFM High-Temperature Refrigerated Air Dryer, 3\/4\" NPT, 115V\/1Ph - PN 4102003871\u003c\/h1\u003e\n\u003ch2\u003eHigh-Temperature Compressed-Air Drying for 25 HP Reciprocating Compressor Systems\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eChicago Pneumatic CPXHT100 High-Temperature Refrigerated Air Dryer, part number 4102003871\u003c\/strong\u003e, is designed to remove moisture from compressed-air systems operating with elevated inlet-air temperatures.\u003c\/p\u003e\n\u003cp\u003eRated for \u003cstrong\u003e100 SCFM at 100 PSIG\u003c\/strong\u003e, the CPXHT100 is an excellent match for many \u003cstrong\u003e25 HP reciprocating air compressors\u003c\/strong\u003e. Its high-temperature design accepts inlet air up to \u003cstrong\u003e180°F\u003c\/strong\u003e, allowing the package to handle hot compressor discharge air without requiring a separately installed aftercooler in properly sized applications.\u003c\/p\u003e\n\u003cp\u003eThe CPXHT100 combines an air-cooled aftercooler, refrigerated air dryer, moisture separator, and electronic condensate drain into one compact package. Hot compressed air is cooled, causing water vapor to condense into liquid. The internal separator removes that moisture from the airflow, and the electronic drain automatically discharges the collected condensate.\u003c\/p\u003e\n\u003cp\u003eWith a pressure dew point of approximately \u003cstrong\u003e50°F ± 2°F\u003c\/strong\u003e, the CPXHT100 helps reduce liquid water in compressed-air piping while protecting pneumatic tools, cylinders, valves, production equipment, paint systems, and finished products from moisture-related problems.\u003c\/p\u003e\n\u003cp\u003eThe dryer operates on standard \u003cstrong\u003e115-volt single-phase power\u003c\/strong\u003e and uses \u003cstrong\u003e3\/4-inch NPT inlet and outlet connections\u003c\/strong\u003e, simplifying installation in automotive facilities, maintenance departments, fabrication shops, woodworking operations, and light-industrial applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer Part Number: 4102003871\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eKey Features and Benefits\u003c\/h2\u003e\n\u003ch3\u003e100 SCFM Rated Capacity\u003c\/h3\u003e\n\u003cp\u003eThe CPXHT100 is rated for \u003cstrong\u003e100 SCFM at 100 PSIG\u003c\/strong\u003e, making it suitable for many 25 HP reciprocating air compressor systems.\u003c\/p\u003e\n\u003cp\u003eActual dryer capacity depends on:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCompressed-air inlet temperature\u003c\/li\u003e\n\u003cli\u003eAmbient temperature\u003c\/li\u003e\n\u003cli\u003eOperating pressure\u003c\/li\u003e\n\u003cli\u003eAirflow demand\u003c\/li\u003e\n\u003cli\u003eRequired pressure dew point\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHandles Inlet Temperatures Up to 180°F\u003c\/h3\u003e\n\u003cp\u003eThe CPXHT100 is specifically designed to handle the elevated discharge temperatures commonly produced by reciprocating air compressors.\u003c\/p\u003e\n\u003cp\u003eIts high-temperature design allows it to accept inlet air up to \u003cstrong\u003e180°F\u003c\/strong\u003e, helping eliminate the need for a separately installed aftercooler in properly sized applications.\u003c\/p\u003e\n\u003ch3\u003eIntegrated Air-Cooled Aftercooler\u003c\/h3\u003e\n\u003cp\u003eThe built-in aftercooler reduces the temperature of the incoming compressed air before it reaches the refrigerated drying circuit.\u003c\/p\u003e\n\u003cp\u003eCooling the air causes a significant portion of the water vapor to condense, allowing the internal moisture separator and drain to remove it from the system.\u003c\/p\u003e\n\u003ch3\u003e50°F Pressure Dew Point\u003c\/h3\u003e\n\u003cp\u003eThe dryer provides a pressure dew point of approximately \u003cstrong\u003e50°F ± 2°F\u003c\/strong\u003e, helping reduce liquid-water formation in downstream piping and equipment.\u003c\/p\u003e\n\u003ch3\u003eIntegrated Moisture Separator\u003c\/h3\u003e\n\u003cp\u003eThe built-in moisture separator removes condensed water from the compressed-air stream after the air has been cooled.\u003c\/p\u003e\n\u003ch3\u003eElectronic Condensate Drain\u003c\/h3\u003e\n\u003cp\u003eAn integrated electronic drain automatically discharges collected condensate, reducing manual maintenance and helping prevent water from accumulating inside the dryer.\u003c\/p\u003e\n\u003ch3\u003eStainless Steel and Copper Heat Exchanger\u003c\/h3\u003e\n\u003cp\u003eThe stainless steel and copper heat exchanger provides dependable thermal transfer while supporting efficient cooling and long-term operation.\u003c\/p\u003e\n\u003ch3\u003e115V Single-Phase Power\u003c\/h3\u003e\n\u003cp\u003eThe CPXHT100 operates on \u003cstrong\u003e115V single-phase, 60 Hz electrical power\u003c\/strong\u003e, eliminating the need for specialized three-phase electrical service.\u003c\/p\u003e\n\u003ch3\u003e3\/4-Inch NPT Connections\u003c\/h3\u003e\n\u003cp\u003eThe dryer uses \u003cstrong\u003e3\/4-inch NPT inlet and outlet connections\u003c\/strong\u003e, simplifying connection to appropriately sized compressed-air piping.\u003c\/p\u003e\n\u003ch3\u003eMaximum Working Pressure of 232 PSIG\u003c\/h3\u003e\n\u003cp\u003eThe CPXHT100 is rated for compressed-air systems operating at pressures up to \u003cstrong\u003e232 PSIG\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eCompact Enclosed Design\u003c\/h3\u003e\n\u003cp\u003eMeasuring approximately \u003cstrong\u003e18 inches long, 23 inches wide, and 41 inches high\u003c\/strong\u003e, the CPXHT100 delivers substantial drying capacity without consuming excessive floor space.\u003c\/p\u003e\n\u003ch3\u003eQuiet Operation\u003c\/h3\u003e\n\u003cp\u003eThe internal layout and enclosed cabinet help reduce operating noise, allowing installation closer to active work areas when proper ventilation is provided.\u003c\/p\u003e\n\u003ch3\u003eHelps Protect Pneumatic Equipment\u003c\/h3\u003e\n\u003cp\u003eRemoving moisture from compressed air helps protect:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePneumatic tools\u003c\/li\u003e\n\u003cli\u003eAir cylinders\u003c\/li\u003e\n\u003cli\u003eImpact tools\u003c\/li\u003e\n\u003cli\u003eTire-service equipment\u003c\/li\u003e\n\u003cli\u003ePaint equipment\u003c\/li\u003e\n\u003cli\u003eRegulators and control valves\u003c\/li\u003e\n\u003cli\u003eProduction machinery\u003c\/li\u003e\n\u003cli\u003eAutomation components\u003c\/li\u003e\n\u003cli\u003eCompressed-air piping\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHelps Improve Finished Product Quality\u003c\/h3\u003e\n\u003cp\u003eDry compressed air can help reduce moisture-related problems in painting, finishing, fabrication, woodworking, assembly, packaging, and manufacturing applications.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eStandard Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e100 SCFM rated airflow at 100 PSIG\u003c\/li\u003e\n\u003cli\u003eDesigned for many 25 HP reciprocating compressors\u003c\/li\u003e\n\u003cli\u003eMaximum inlet-air temperature of 180°F\u003c\/li\u003e\n\u003cli\u003e50°F pressure dew point, ±2°F\u003c\/li\u003e\n\u003cli\u003eMaximum working pressure of 232 PSIG\u003c\/li\u003e\n\u003cli\u003e115V single-phase electrical power\u003c\/li\u003e\n\u003cli\u003e60 Hz operation\u003c\/li\u003e\n\u003cli\u003e3\/4-inch NPT inlet and outlet connections\u003c\/li\u003e\n\u003cli\u003eIntegrated air-cooled aftercooler\u003c\/li\u003e\n\u003cli\u003eRefrigerated air dryer\u003c\/li\u003e\n\u003cli\u003eStainless steel and copper heat exchanger\u003c\/li\u003e\n\u003cli\u003eBuilt-in moisture separator\u003c\/li\u003e\n\u003cli\u003eElectronic condensate drain\u003c\/li\u003e\n\u003cli\u003eCompact enclosed cabinet\u003c\/li\u003e\n\u003cli\u003eAir-cooled refrigeration system\u003c\/li\u003e\n\u003cli\u003eR-404A refrigerant\u003c\/li\u003e\n\u003cli\u003eQuiet internal layout\u003c\/li\u003e\n\u003cli\u003eDesigned for hot compressor discharge air\u003c\/li\u003e\n\u003cli\u003eSimplified installation and maintenance\u003c\/li\u003e\n\u003cli\u003eMinimum ambient temperature of 41°F\u003c\/li\u003e\n\u003cli\u003eMaximum ambient temperature of 113°F\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eChicago Pneumatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCPXHT100 (H4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer Part Number\u003c\/td\u003e\n\u003ctd\u003e4102003871\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDryer Type\u003c\/td\u003e\n\u003ctd\u003eHigh-temperature refrigerated air dryer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Airflow\u003c\/td\u003e\n\u003ctd\u003e100 SCFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Flow Conditions\u003c\/td\u003e\n\u003ctd\u003e100 PSIG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Compressor Size\u003c\/td\u003e\n\u003ctd\u003e25 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Dew Point\u003c\/td\u003e\n\u003ctd\u003e50°F ± 2°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Inlet-Air Temperature\u003c\/td\u003e\n\u003ctd\u003e180°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Ambient Temperature\u003c\/td\u003e\n\u003ctd\u003e41°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Ambient Temperature\u003c\/td\u003e\n\u003ctd\u003e113°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Working Pressure\u003c\/td\u003e\n\u003ctd\u003e232 PSIG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Inlet Connection\u003c\/td\u003e\n\u003ctd\u003e3\/4-inch NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Outlet Connection\u003c\/td\u003e\n\u003ctd\u003e3\/4-inch NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e115V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eSingle phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat Exchanger\u003c\/td\u003e\n\u003ctd\u003eStainless steel and copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated Aftercooler\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMoisture Separator\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectronic Condensate Drain\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-404A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproximate Length\u003c\/td\u003e\n\u003ctd\u003e18 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproximate Width\u003c\/td\u003e\n\u003ctd\u003e23 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproximate Height\u003c\/td\u003e\n\u003ctd\u003e41 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproximate Weight\u003c\/td\u003e\n\u003ctd\u003e231 pounds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eRecommended Applications\u003c\/h2\u003e\n\u003cp\u003eThe Chicago Pneumatic CPXHT100 is well suited for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAutomotive repair shops\u003c\/li\u003e\n\u003cli\u003eCollision repair and body shops\u003c\/li\u003e\n\u003cli\u003eTire-service facilities\u003c\/li\u003e\n\u003cli\u003eFleet-maintenance departments\u003c\/li\u003e\n\u003cli\u003eMetal fabrication shops\u003c\/li\u003e\n\u003cli\u003eWoodworking and cabinet shops\u003c\/li\u003e\n\u003cli\u003eMaintenance departments\u003c\/li\u003e\n\u003cli\u003eManufacturing facilities\u003c\/li\u003e\n\u003cli\u003ePaint and finishing operations\u003c\/li\u003e\n\u003cli\u003ePneumatic assembly equipment\u003c\/li\u003e\n\u003cli\u003eAir-operated production tools\u003c\/li\u003e\n\u003cli\u003eCommercial garages\u003c\/li\u003e\n\u003cli\u003ePackaging equipment\u003c\/li\u003e\n\u003cli\u003ePlastics-processing operations\u003c\/li\u003e\n\u003cli\u003eSmall production facilities\u003c\/li\u003e\n\u003cli\u003eReciprocating air compressor systems\u003c\/li\u003e\n\u003cli\u003e25 HP compressor applications\u003c\/li\u003e\n\u003cli\u003eFacilities without a separate compressor aftercooler\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe dryer should be sized according to the compressor’s actual airflow, operating pressure, inlet-air temperature, ambient temperature, and required air quality.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eWhy Choose a High-Temperature Refrigerated Air Dryer?\u003c\/h2\u003e\n\u003cp\u003eCompressed air leaving a reciprocating compressor can be extremely hot. A conventional refrigerated air dryer may not be designed to accept this elevated temperature without a separate aftercooler.\u003c\/p\u003e\n\u003cp\u003eThe CPXHT100 combines an air-cooled aftercooler and refrigerated dryer into one package, allowing it to accept inlet-air temperatures up to \u003cstrong\u003e180°F\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003ePotential advantages include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEliminates the need for a separate aftercooler in properly sized applications\u003c\/li\u003e\n\u003cli\u003eReduces installation complexity\u003c\/li\u003e\n\u003cli\u003eSaves valuable floor space\u003c\/li\u003e\n\u003cli\u003eReduces external piping requirements\u003c\/li\u003e\n\u003cli\u003eAutomatically removes condensed moisture\u003c\/li\u003e\n\u003cli\u003eHelps protect downstream equipment\u003c\/li\u003e\n\u003cli\u003eReduces water accumulation in air lines\u003c\/li\u003e\n\u003cli\u003eReduces manual air-line purging\u003c\/li\u003e\n\u003cli\u003eSupports more consistent compressed-air quality\u003c\/li\u003e\n\u003cli\u003eHelps reduce moisture-related maintenance\u003c\/li\u003e\n\u003cli\u003eHelps minimize production downtime\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eHow the CPXHT100 Works\u003c\/h2\u003e\n\u003ch3\u003eStage 1: Hot Compressed Air Enters the Dryer\u003c\/h3\u003e\n\u003cp\u003eHot compressed air enters the CPXHT100 through the 3\/4-inch NPT inlet.\u003c\/p\u003e\n\u003ch3\u003eStage 2: The Integrated Aftercooler Reduces Air Temperature\u003c\/h3\u003e\n\u003cp\u003eThe built-in air-cooled aftercooler reduces the temperature of the incoming compressed air. As the air cools, water vapor begins to condense into liquid.\u003c\/p\u003e\n\u003ch3\u003eStage 3: The Refrigerated Dryer Further Cools the Air\u003c\/h3\u003e\n\u003cp\u003eThe refrigerated drying circuit lowers the air temperature further, allowing additional moisture to condense.\u003c\/p\u003e\n\u003ch3\u003eStage 4: Condensed Moisture Is Separated\u003c\/h3\u003e\n\u003cp\u003eThe integrated moisture separator removes liquid water from the compressed-air stream.\u003c\/p\u003e\n\u003ch3\u003eStage 5: Condensate Is Automatically Discharged\u003c\/h3\u003e\n\u003cp\u003eThe electronic condensate drain removes collected moisture without requiring routine manual draining.\u003c\/p\u003e\n\u003ch3\u003eStage 6: Drier Air Enters the Distribution System\u003c\/h3\u003e\n\u003cp\u003eThe treated compressed air exits the dryer and enters the facility’s compressed-air piping system.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eBenefits of Dry Compressed Air\u003c\/h2\u003e\n\u003cp\u003eAtmospheric air naturally contains water vapor. When air is compressed, that moisture becomes concentrated. As the compressed air cools inside the receiver tank and distribution piping, the water vapor can condense into liquid.\u003c\/p\u003e\n\u003cp\u003eExcessive moisture can contribute to:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInternal piping corrosion\u003c\/li\u003e\n\u003cli\u003eDamaged pneumatic tools\u003c\/li\u003e\n\u003cli\u003eSticking air cylinders\u003c\/li\u003e\n\u003cli\u003eRust inside air receivers and piping\u003c\/li\u003e\n\u003cli\u003eContaminated paint finishes\u003c\/li\u003e\n\u003cli\u003eFisheye paint defects\u003c\/li\u003e\n\u003cli\u003eDamaged regulators and valves\u003c\/li\u003e\n\u003cli\u003eIncreased equipment maintenance\u003c\/li\u003e\n\u003cli\u003eReduced production quality\u003c\/li\u003e\n\u003cli\u003eFrozen outdoor air lines\u003c\/li\u003e\n\u003cli\u003eUnplanned downtime\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe CPXHT100 cools the compressed air, separates condensed moisture, and automatically discharges the collected water.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eAir Treatment Recommendations\u003c\/h2\u003e\n\u003cp\u003eA refrigerated air dryer primarily removes water vapor and condensed moisture. Some applications may require additional air treatment for particulate contamination, fine oil aerosols, odors, or other contaminants.\u003c\/p\u003e\n\u003cp\u003eDepending on the application, the compressed-air system may also require:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAutomatic receiver-tank drain\u003c\/li\u003e\n\u003cli\u003eGeneral-purpose particulate filter\u003c\/li\u003e\n\u003cli\u003eHigh-efficiency coalescing filter\u003c\/li\u003e\n\u003cli\u003eActivated-carbon filter\u003c\/li\u003e\n\u003cli\u003ePressure regulator\u003c\/li\u003e\n\u003cli\u003eOil-water separator\u003c\/li\u003e\n\u003cli\u003ePoint-of-use air treatment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003ePaint spraying, instrumentation, automation systems, and sensitive production applications may require additional treatment beyond a refrigerated air dryer.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eDryer Sizing Considerations\u003c\/h2\u003e\n\u003cp\u003eThe CPXHT100 is rated for \u003cstrong\u003e100 SCFM at 100 PSIG\u003c\/strong\u003e under the manufacturer’s reference conditions.\u003c\/p\u003e\n\u003cp\u003eDryer capacity may decrease when:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInlet-air temperature increases\u003c\/li\u003e\n\u003cli\u003eAmbient temperature increases\u003c\/li\u003e\n\u003cli\u003eOperating pressure decreases\u003c\/li\u003e\n\u003cli\u003eAirflow demand increases\u003c\/li\u003e\n\u003cli\u003eCompressor discharge temperature exceeds the rated limit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe dryer should be selected according to the most demanding expected operating conditions rather than only the compressor’s nominal horsepower.\u003c\/p\u003e\n\u003cp\u003eA 25 HP compressor may produce more or less than 100 SCFM depending on the compressor design, operating pressure, pump speed, and efficiency.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eInstallation Considerations\u003c\/h2\u003e\n\u003cp\u003eThe CPXHT100 should be installed indoors in a clean, well-ventilated location with adequate room for inspection and maintenance.\u003c\/p\u003e\n\u003cp\u003eBefore installation:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eConfirm that system airflow does not exceed the dryer’s 100 SCFM rated capacity.\u003c\/li\u003e\n\u003cli\u003eVerify that the dryer is suitable for the compressor’s actual inlet-air temperature.\u003c\/li\u003e\n\u003cli\u003eConfirm that operating pressure does not exceed 232 PSIG.\u003c\/li\u003e\n\u003cli\u003eConfirm that ambient temperature remains between 41°F and 113°F.\u003c\/li\u003e\n\u003cli\u003eProvide a 115V single-phase, 60 Hz electrical supply.\u003c\/li\u003e\n\u003cli\u003eVerify that the electrical circuit meets the dryer’s nameplate requirements.\u003c\/li\u003e\n\u003cli\u003eUse properly sized compressed-air piping.\u003c\/li\u003e\n\u003cli\u003eConfirm the correct compressed-air flow direction.\u003c\/li\u003e\n\u003cli\u003eKeep the condenser and ventilation openings clear.\u003c\/li\u003e\n\u003cli\u003ePrevent heated exhaust air from recirculating into the dryer.\u003c\/li\u003e\n\u003cli\u003eRoute the electronic drain discharge to an approved condensate collection or treatment system.\u003c\/li\u003e\n\u003cli\u003eProvide isolation valves to simplify future maintenance.\u003c\/li\u003e\n\u003cli\u003eConsider installing a bypass line so the dryer can be serviced without shutting down the entire compressed-air system.\u003c\/li\u003e\n\u003cli\u003eAvoid unnecessary piping restrictions at the inlet and outlet.\u003c\/li\u003e\n\u003cli\u003eSupport external piping so its weight is not carried by the dryer connections.\u003c\/li\u003e\n\u003cli\u003eMaintain the manufacturer’s recommended service clearances.\u003c\/li\u003e\n\u003cli\u003eCheck the compressed-air system for leaks after installation.\u003c\/li\u003e\n\u003cli\u003eConfirm proper condensate-drain operation before placing the dryer into regular service.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eInstallation should be completed according to the supplied operating instructions and all applicable electrical, plumbing, and safety codes.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eRoutine Maintenance\u003c\/h2\u003e\n\u003cp\u003eRoutine inspection helps maintain moisture removal, cooling performance, and dependable dryer operation.\u003c\/p\u003e\n\u003cp\u003eTypical maintenance includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVerify that the electronic condensate drain is operating.\u003c\/li\u003e\n\u003cli\u003eInspect the drain discharge line for restrictions.\u003c\/li\u003e\n\u003cli\u003eKeep the condenser and ventilation openings clean.\u003c\/li\u003e\n\u003cli\u003eRemove accumulated dust and debris from cooling surfaces.\u003c\/li\u003e\n\u003cli\u003eCheck the dryer for unusual noise or vibration.\u003c\/li\u003e\n\u003cli\u003eInspect compressed-air fittings for leaks.\u003c\/li\u003e\n\u003cli\u003eVerify that inlet-air temperature remains within the rated limit.\u003c\/li\u003e\n\u003cli\u003eConfirm that ambient temperature remains within the allowable range.\u003c\/li\u003e\n\u003cli\u003eInspect electrical wiring and connections.\u003c\/li\u003e\n\u003cli\u003eCheck for excessive pressure drop through the dryer.\u003c\/li\u003e\n\u003cli\u003eKeep surrounding areas free from dust, debris, and stored materials.\u003c\/li\u003e\n\u003cli\u003eFollow the maintenance instructions supplied with the unit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eMaintenance frequency can vary based on operating hours, dust levels, ambient temperature, humidity, and compressor operating conditions.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eBasic Troubleshooting\u003c\/h2\u003e\n\u003ch3\u003eWater Is Present Downstream\u003c\/h3\u003e\n\u003cp\u003eCheck the electronic drain, drain discharge line, inlet-air temperature, airflow demand, ambient temperature, operating pressure, and dryer ventilation.\u003c\/p\u003e\n\u003cp\u003eThe dryer may be undersized if actual operating conditions exceed its rated capacity.\u003c\/p\u003e\n\u003ch3\u003eElectronic Drain Does Not Discharge\u003c\/h3\u003e\n\u003cp\u003eCheck the drain’s electrical connection, timer or control operation, isolation valve, discharge tubing, and condensate outlet for blockages.\u003c\/p\u003e\n\u003ch3\u003eDryer Does Not Start\u003c\/h3\u003e\n\u003cp\u003eCheck the electrical outlet, disconnect, circuit protection, power connection, dryer switch, and incoming voltage.\u003c\/p\u003e\n\u003ch3\u003eDryer Runs but Does Not Remove Moisture\u003c\/h3\u003e\n\u003cp\u003eVerify that the refrigeration system is operating, the condenser is clean, the condensate drain is functioning, and inlet conditions remain within the dryer’s rated limits.\u003c\/p\u003e\n\u003ch3\u003eExcessive Pressure Drop\u003c\/h3\u003e\n\u003cp\u003eInspect the compressed-air piping, valves, fittings, heat exchanger, and downstream air-treatment components for restrictions.\u003c\/p\u003e\n\u003ch3\u003eDryer Shuts Down or Runs Hot\u003c\/h3\u003e\n\u003cp\u003eCheck the ambient temperature, ventilation clearance, condenser cleanliness, and whether heated exhaust air is recirculating into the dryer.\u003c\/p\u003e\n\u003ch3\u003eExcessive Condensate in the Air System\u003c\/h3\u003e\n\u003cp\u003eConfirm that the air receiver is draining properly and that the dryer is installed and sized correctly for the compressor’s airflow and discharge temperature.\u003c\/p\u003e\n\u003ch3\u003eDryer Runs Continuously\u003c\/h3\u003e\n\u003cp\u003eContinuous operation may be normal for a non-cycling refrigerated dryer. Check the operating manual and verify that the unit is maintaining the proper dew point.\u003c\/p\u003e\n\u003ch3\u003eUnusual Noise or Vibration\u003c\/h3\u003e\n\u003cp\u003eCheck for loose cabinet panels, debris near the cooling fan, improper mounting, refrigerant-compressor issues, or damaged internal components.\u003c\/p\u003e\n\u003cp\u003eRefrigeration-system repairs, electrical repairs, internal pressure-system repairs, and major service should be completed by qualified personnel.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eFrequently Asked Questions\u003c\/h1\u003e\n\u003ch2\u003eWhat is the rated capacity of the CPXHT100?\u003c\/h2\u003e\n\u003cp\u003eThe CPXHT100 is rated for \u003cstrong\u003e100 SCFM at 100 PSIG\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat is the manufacturer part number?\u003c\/h2\u003e\n\u003cp\u003eThe manufacturer part number is \u003cstrong\u003e4102003871\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat makes this a high-temperature air dryer?\u003c\/h2\u003e\n\u003cp\u003eThe CPXHT100 can accept compressed-air inlet temperatures up to \u003cstrong\u003e180°F\u003c\/strong\u003e and incorporates an air-cooled aftercooler into the dryer package.\u003c\/p\u003e\n\u003ch2\u003eWhat size compressor is the CPXHT100 designed for?\u003c\/h2\u003e\n\u003cp\u003eIt is designed for many \u003cstrong\u003e25 HP reciprocating air compressors\u003c\/strong\u003e, provided the compressor’s actual airflow and operating conditions remain within the dryer’s rated capacity.\u003c\/p\u003e\n\u003ch2\u003eWhat pressure dew point does it provide?\u003c\/h2\u003e\n\u003cp\u003eThe CPXHT100 provides a pressure dew point of approximately \u003cstrong\u003e50°F ± 2°F\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eDoes the CPXHT100 include an aftercooler?\u003c\/h2\u003e\n\u003cp\u003eYes. The high-temperature package includes an integrated air-cooled aftercooler.\u003c\/p\u003e\n\u003ch2\u003eDoes the dryer include a moisture separator?\u003c\/h2\u003e\n\u003cp\u003eYes. The CPXHT100 includes an integrated moisture separator.\u003c\/p\u003e\n\u003ch2\u003eDoes it include an automatic condensate drain?\u003c\/h2\u003e\n\u003cp\u003eYes. The dryer includes an electronic condensate drain that automatically discharges collected moisture.\u003c\/p\u003e\n\u003ch2\u003eWhat electrical service is required?\u003c\/h2\u003e\n\u003cp\u003eThe CPXHT100 requires \u003cstrong\u003e115V single-phase, 60 Hz electrical power\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat size are the air connections?\u003c\/h2\u003e\n\u003cp\u003eThe dryer uses \u003cstrong\u003e3\/4-inch NPT inlet and outlet connections\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat is the maximum operating pressure?\u003c\/h2\u003e\n\u003cp\u003eThe maximum working pressure is \u003cstrong\u003e232 PSIG\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat is the allowable ambient-temperature range?\u003c\/h2\u003e\n\u003cp\u003eThe dryer is designed for ambient temperatures between \u003cstrong\u003e41°F and 113°F\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat refrigerant does the CPXHT100 use?\u003c\/h2\u003e\n\u003cp\u003eThe CPXHT100 uses \u003cstrong\u003eR-404A refrigerant\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eDoes this dryer remove oil?\u003c\/h2\u003e\n\u003cp\u003eA refrigerated dryer is primarily designed to remove moisture. Additional air treatment may be required to remove fine oil aerosols, particulate contamination, or odors.\u003c\/p\u003e\n\u003ch2\u003eDoes the CPXHT100 replace a separate aftercooler?\u003c\/h2\u003e\n\u003cp\u003eThe integrated high-temperature design can eliminate the need for a separately installed aftercooler in properly sized applications with inlet temperatures up to 180°F.\u003c\/p\u003e\n\u003ch2\u003eCan this dryer be used with a rotary screw compressor?\u003c\/h2\u003e\n\u003cp\u003eIt can, but a standard refrigerated dryer may be more appropriate when the rotary screw compressor’s discharge temperature remains within conventional dryer inlet-temperature limits.\u003c\/p\u003e\n\u003ch2\u003eCan this dryer be used for automotive painting?\u003c\/h2\u003e\n\u003cp\u003eYes, provided it is properly sized. Paint applications may also require coalescing and point-of-use air treatment depending on the required finish quality.\u003c\/p\u003e\n\u003ch2\u003eDoes a 25 HP compressor always produce less than 100 CFM?\u003c\/h2\u003e\n\u003cp\u003eNo. Compressor output varies by model, operating pressure, pump speed, and design. Dryer selection should always be based on actual airflow and operating conditions.\u003c\/p\u003e\n\u003ch2\u003eWhere should the condensate drain discharge be routed?\u003c\/h2\u003e\n\u003cp\u003eCondensate should be routed to an appropriate collection or oil-water separation system according to applicable regulations.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eWhy Buy from Compressed Air Advisors Online?\u003c\/h2\u003e\n\u003cp\u003eCompressed Air Advisors Online provides knowledgeable compressed-air equipment selection, system guidance, premium industrial products, and nationwide delivery.\u003c\/p\u003e\n\u003cp\u003eOur team can help determine whether the Chicago Pneumatic CPXHT100 provides the correct capacity, inlet-temperature rating, operating pressure, connections, and electrical configuration for your compressed-air system.\u003c\/p\u003e\n\u003cp\u003eWhen you need dependable air-treatment equipment backed by practical compressed-air knowledge, Compressed Air Advisors Online is your compressed-air partner.\u003c\/p\u003e","brand":"Chicago Pneumatic","offers":[{"title":"Default Title","offer_id":46090094608454,"sku":"4102003871","price":5969.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0014\/6237\/0374\/products\/cpxht25.jpg?v=1646424665","url":"https:\/\/www.compressedairadvisors.com\/products\/chicago-pneumatic-cpxht50-h2-50-scfm-high-temperature-refrigerated-air-dryer-1-npt-115v-1ph-pn-4102003869-copy","provider":"Compressed Air Advisors Online, Inc. ","version":"1.0","type":"link"}