{"product_id":"chicago-pneumatic-cpxht50-high-temperature-dryer-4102003869","title":"Chicago Pneumatic CPXHT50 (H2) 50 SCFM High-Temperature Refrigerated Air Dryer, 1\" NPT, 115V\/1Ph - PN 4102003869","description":"\u003ch1 class=\"PDq2pG_selectionAnchorContainer\"\u003eChicago Pneumatic CPXHT50 (H2) 50 SCFM High-Temperature Refrigerated Air Dryer, 1\" NPT, 115V\/1Ph - PN 4102003869\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003ch2\u003eHigh-Temperature Moisture Removal for 10 to 15 HP Reciprocating Air Compressors\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eChicago Pneumatic CPXHT50 High-Temperature Refrigerated Air Dryer, part number 4102003869\u003c\/strong\u003e, is engineered to remove moisture from compressed-air systems operating with elevated inlet-air temperatures.\u003c\/p\u003e\n\u003cp\u003eRated for \u003cstrong\u003e50 SCFM at 100 PSIG\u003c\/strong\u003e, the CPXHT50 can accept compressed-air inlet temperatures up to \u003cstrong\u003e180°F\u003c\/strong\u003e. This high-temperature capability makes it an excellent match for many \u003cstrong\u003e10 to 15 HP reciprocating air compressors\u003c\/strong\u003e, including systems that do not have a separate air-cooled aftercooler.\u003c\/p\u003e\n\u003cp\u003eThe CPXHT50 combines a refrigerated air dryer, moisture separator, and electronic condensate drain in one compact package. As hot compressed air passes through the dryer, it is cooled so water vapor condenses into liquid. The integrated separator removes the condensate from the airflow, while the electronic drain automatically discharges the collected moisture.\u003c\/p\u003e\n\u003cp\u003eWith a pressure dew point of approximately \u003cstrong\u003e50°F ± 2°F\u003c\/strong\u003e, the CPXHT50 helps reduce water accumulation inside compressed-air piping and protects pneumatic tools, cylinders, valves, production equipment, and finished products from moisture-related problems.\u003c\/p\u003e\n\u003cp\u003eThe dryer operates on standard \u003cstrong\u003e115-volt single-phase power\u003c\/strong\u003e and uses \u003cstrong\u003e1-inch NPT inlet and outlet connections\u003c\/strong\u003e, simplifying installation in automotive shops, fabrication facilities, maintenance departments, woodworking operations, and other commercial or light-industrial applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer Part Number: 4102003869\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eKey Features and Benefits\u003c\/h2\u003e\n\u003ch3\u003e50 SCFM Rated Capacity\u003c\/h3\u003e\n\u003cp\u003eThe CPXHT50 is rated for \u003cstrong\u003e50 SCFM at 100 PSIG\u003c\/strong\u003e, making it suitable for many 10 to 15 HP reciprocating air compressor systems.\u003c\/p\u003e\n\u003cp\u003eActual dryer capacity can vary based on:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCompressed-air inlet temperature\u003c\/li\u003e\n\u003cli\u003eAmbient temperature\u003c\/li\u003e\n\u003cli\u003eOperating pressure\u003c\/li\u003e\n\u003cli\u003eAirflow demand\u003c\/li\u003e\n\u003cli\u003eRequired pressure dew point\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHandles Inlet Temperatures Up to 180°F\u003c\/h3\u003e\n\u003cp\u003eThe CPXHT50 is specifically designed to accept high-temperature compressed air produced by reciprocating compressors.\u003c\/p\u003e\n\u003cp\u003eIts \u003cstrong\u003e180°F maximum inlet-air temperature\u003c\/strong\u003e can eliminate the need for a separately installed aftercooler when the dryer is properly sized for the application.\u003c\/p\u003e\n\u003ch3\u003e50°F Pressure Dew Point\u003c\/h3\u003e\n\u003cp\u003eThe dryer provides a pressure dew point of approximately \u003cstrong\u003e50°F ± 2°F\u003c\/strong\u003e, helping reduce liquid water formation in downstream piping and equipment.\u003c\/p\u003e\n\u003ch3\u003eIntegrated Moisture Separator\u003c\/h3\u003e\n\u003cp\u003eThe built-in moisture separator removes condensed water from the compressed-air stream after it has been cooled.\u003c\/p\u003e\n\u003ch3\u003eElectronic Condensate Drain\u003c\/h3\u003e\n\u003cp\u003eAn integrated electronic drain automatically discharges collected condensate, reducing manual maintenance and helping prevent moisture from accumulating inside the dryer.\u003c\/p\u003e\n\u003ch3\u003eStainless Steel and Copper Heat Exchanger\u003c\/h3\u003e\n\u003cp\u003eThe stainless steel and copper heat exchanger provides efficient thermal transfer while supporting dependable operation in demanding compressed-air environments.\u003c\/p\u003e\n\u003ch3\u003e115V Single-Phase Power\u003c\/h3\u003e\n\u003cp\u003eThe CPXHT50 operates on \u003cstrong\u003e115V single-phase, 60 Hz electrical power\u003c\/strong\u003e, eliminating the need for specialized three-phase electrical service.\u003c\/p\u003e\n\u003ch3\u003e1-Inch NPT Connections\u003c\/h3\u003e\n\u003cp\u003eThe dryer uses \u003cstrong\u003e1-inch NPT inlet and outlet connections\u003c\/strong\u003e, providing appropriate piping capacity for its 50 SCFM airflow rating.\u003c\/p\u003e\n\u003ch3\u003eMaximum Working Pressure of 232 PSIG\u003c\/h3\u003e\n\u003cp\u003eThe CPXHT50 is rated for compressed-air systems operating at pressures up to \u003cstrong\u003e232 PSIG\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eCompact Enclosed Design\u003c\/h3\u003e\n\u003cp\u003eMeasuring approximately \u003cstrong\u003e18 inches long, 23 inches wide, and 31 inches high\u003c\/strong\u003e, the CPXHT50 provides high-temperature drying capability in a relatively compact footprint.\u003c\/p\u003e\n\u003ch3\u003eQuiet Operation\u003c\/h3\u003e\n\u003cp\u003eThe internal component layout and enclosed cabinet help reduce operating noise, making the dryer suitable for installation near active work areas when proper ventilation is provided.\u003c\/p\u003e\n\u003ch3\u003eHelps Protect Pneumatic Equipment\u003c\/h3\u003e\n\u003cp\u003eRemoving moisture from compressed air helps protect:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePneumatic tools\u003c\/li\u003e\n\u003cli\u003eAir cylinders\u003c\/li\u003e\n\u003cli\u003eImpact tools\u003c\/li\u003e\n\u003cli\u003eTire-service equipment\u003c\/li\u003e\n\u003cli\u003ePaint equipment\u003c\/li\u003e\n\u003cli\u003eRegulators and valves\u003c\/li\u003e\n\u003cli\u003eProduction machinery\u003c\/li\u003e\n\u003cli\u003eAutomation components\u003c\/li\u003e\n\u003cli\u003eCompressed-air piping\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHelps Improve Finished Product Quality\u003c\/h3\u003e\n\u003cp\u003eDry compressed air can help reduce moisture-related problems in painting, finishing, fabrication, woodworking, assembly, and manufacturing applications.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eStandard Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e50 SCFM rated airflow at 100 PSIG\u003c\/li\u003e\n\u003cli\u003eMaximum inlet-air temperature of 180°F\u003c\/li\u003e\n\u003cli\u003e50°F pressure dew point, ±2°F\u003c\/li\u003e\n\u003cli\u003eMaximum working pressure of 232 PSIG\u003c\/li\u003e\n\u003cli\u003e115V single-phase electrical power\u003c\/li\u003e\n\u003cli\u003e60 Hz operation\u003c\/li\u003e\n\u003cli\u003e1-inch NPT inlet and outlet connections\u003c\/li\u003e\n\u003cli\u003eStainless steel and copper heat exchanger\u003c\/li\u003e\n\u003cli\u003eIntegrated refrigerated air dryer\u003c\/li\u003e\n\u003cli\u003eBuilt-in moisture separator\u003c\/li\u003e\n\u003cli\u003eElectronic condensate drain\u003c\/li\u003e\n\u003cli\u003eCompact enclosed cabinet\u003c\/li\u003e\n\u003cli\u003eAir-cooled refrigeration system\u003c\/li\u003e\n\u003cli\u003eR-404A refrigerant\u003c\/li\u003e\n\u003cli\u003eDesigned for high-temperature compressor discharge air\u003c\/li\u003e\n\u003cli\u003eRecommended for many 10 to 15 HP reciprocating compressors\u003c\/li\u003e\n\u003cli\u003eMinimum ambient temperature of 41°F\u003c\/li\u003e\n\u003cli\u003eMaximum ambient temperature of 113°F\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eChicago Pneumatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCPXHT50 (H2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer Part Number\u003c\/td\u003e\n\u003ctd\u003e4102003869\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDryer Type\u003c\/td\u003e\n\u003ctd\u003eHigh-temperature refrigerated air dryer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Airflow\u003c\/td\u003e\n\u003ctd\u003e50 SCFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Flow Conditions\u003c\/td\u003e\n\u003ctd\u003e100 PSIG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Compressor Range\u003c\/td\u003e\n\u003ctd\u003e10 to 15 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Dew Point\u003c\/td\u003e\n\u003ctd\u003e50°F ± 2°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Inlet-Air Temperature\u003c\/td\u003e\n\u003ctd\u003e180°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Ambient Temperature\u003c\/td\u003e\n\u003ctd\u003e41°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Ambient Temperature\u003c\/td\u003e\n\u003ctd\u003e113°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Working Pressure\u003c\/td\u003e\n\u003ctd\u003e232 PSIG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Inlet Connection\u003c\/td\u003e\n\u003ctd\u003e1-inch NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Outlet Connection\u003c\/td\u003e\n\u003ctd\u003e1-inch NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e115V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eSingle phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat Exchanger\u003c\/td\u003e\n\u003ctd\u003eStainless steel and copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMoisture Separator\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectronic Condensate Drain\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-404A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproximate Length\u003c\/td\u003e\n\u003ctd\u003e18 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproximate Width\u003c\/td\u003e\n\u003ctd\u003e23 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproximate Height\u003c\/td\u003e\n\u003ctd\u003e31 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproximate Weight\u003c\/td\u003e\n\u003ctd\u003e108 pounds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003ch2\u003eRecommended Applications\u003c\/h2\u003e\n\u003cp\u003eThe Chicago Pneumatic CPXHT50 is well suited for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAutomotive repair shops\u003c\/li\u003e\n\u003cli\u003eCollision repair and body shops\u003c\/li\u003e\n\u003cli\u003eTire-service facilities\u003c\/li\u003e\n\u003cli\u003eFleet-maintenance departments\u003c\/li\u003e\n\u003cli\u003eMetal fabrication shops\u003c\/li\u003e\n\u003cli\u003eWoodworking and cabinet shops\u003c\/li\u003e\n\u003cli\u003eMaintenance departments\u003c\/li\u003e\n\u003cli\u003eLight manufacturing\u003c\/li\u003e\n\u003cli\u003ePaint and finishing operations\u003c\/li\u003e\n\u003cli\u003ePneumatic assembly equipment\u003c\/li\u003e\n\u003cli\u003eAir-operated production tools\u003c\/li\u003e\n\u003cli\u003eCommercial garages\u003c\/li\u003e\n\u003cli\u003ePackaging equipment\u003c\/li\u003e\n\u003cli\u003eSmall production facilities\u003c\/li\u003e\n\u003cli\u003eReciprocating air compressor systems\u003c\/li\u003e\n\u003cli\u003e10 HP compressor applications\u003c\/li\u003e\n\u003cli\u003e15 HP compressor applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe dryer should be sized according to the compressor’s actual airflow, operating pressure, inlet-air temperature, and maximum ambient temperature.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eWhy Choose a High-Temperature Refrigerated Air Dryer?\u003c\/h2\u003e\n\u003cp\u003eCompressed air leaving a reciprocating compressor can be extremely hot. A standard refrigerated air dryer may not be designed to accept this elevated temperature without a separate aftercooler.\u003c\/p\u003e\n\u003cp\u003eThe CPXHT50 is designed to accept inlet-air temperatures up to \u003cstrong\u003e180°F\u003c\/strong\u003e, allowing it to handle hot discharge air from many reciprocating compressors.\u003c\/p\u003e\n\u003cp\u003ePotential advantages include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMay eliminate the need for a separate aftercooler\u003c\/li\u003e\n\u003cli\u003eReduces installation complexity\u003c\/li\u003e\n\u003cli\u003eSaves floor space\u003c\/li\u003e\n\u003cli\u003eReduces external piping requirements\u003c\/li\u003e\n\u003cli\u003eAutomatically removes condensed moisture\u003c\/li\u003e\n\u003cli\u003eHelps protect downstream equipment\u003c\/li\u003e\n\u003cli\u003eReduces water accumulation in air lines\u003c\/li\u003e\n\u003cli\u003eReduces manual air-line purging\u003c\/li\u003e\n\u003cli\u003eSupports more consistent compressed-air quality\u003c\/li\u003e\n\u003cli\u003eHelps reduce moisture-related maintenance and downtime\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eBenefits of Dry Compressed Air\u003c\/h2\u003e\n\u003cp\u003eAtmospheric air naturally contains water vapor. When air is compressed, that moisture becomes concentrated. As the compressed air cools inside the receiver tank and distribution piping, the water vapor can condense into liquid.\u003c\/p\u003e\n\u003cp\u003eExcessive moisture can contribute to:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInternal piping corrosion\u003c\/li\u003e\n\u003cli\u003eDamaged pneumatic tools\u003c\/li\u003e\n\u003cli\u003eSticking air cylinders\u003c\/li\u003e\n\u003cli\u003eRust inside air receivers and piping\u003c\/li\u003e\n\u003cli\u003eContaminated paint finishes\u003c\/li\u003e\n\u003cli\u003eFisheye paint defects\u003c\/li\u003e\n\u003cli\u003eDamaged regulators and valves\u003c\/li\u003e\n\u003cli\u003eIncreased equipment maintenance\u003c\/li\u003e\n\u003cli\u003eReduced production quality\u003c\/li\u003e\n\u003cli\u003eFrozen outdoor air lines\u003c\/li\u003e\n\u003cli\u003eUnplanned downtime\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe CPXHT50 cools the compressed air, separates condensed moisture, and automatically discharges the collected water.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eAir Treatment Recommendations\u003c\/h2\u003e\n\u003cp\u003eA refrigerated air dryer primarily removes water vapor and condensed moisture. Some applications may require additional air treatment for particulate contamination, fine oil aerosols, odors, or other contaminants.\u003c\/p\u003e\n\u003cp\u003eDepending on the application, the compressed-air system may also require:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAutomatic receiver-tank drain\u003c\/li\u003e\n\u003cli\u003eGeneral-purpose particulate filter\u003c\/li\u003e\n\u003cli\u003eHigh-efficiency coalescing filter\u003c\/li\u003e\n\u003cli\u003eActivated-carbon filter\u003c\/li\u003e\n\u003cli\u003ePressure regulator\u003c\/li\u003e\n\u003cli\u003eOil-water separator\u003c\/li\u003e\n\u003cli\u003ePoint-of-use air treatment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003ePaint spraying, instrumentation, and sensitive production applications may require additional treatment beyond a refrigerated air dryer.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eInstallation Considerations\u003c\/h2\u003e\n\u003cp\u003eThe CPXHT50 should be installed indoors in a clean, well-ventilated location with adequate room for inspection and maintenance.\u003c\/p\u003e\n\u003cp\u003eBefore installation:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eConfirm that system airflow does not exceed the dryer’s 50 SCFM rated capacity.\u003c\/li\u003e\n\u003cli\u003eVerify that the dryer is suitable for the compressor’s actual inlet-air temperature.\u003c\/li\u003e\n\u003cli\u003eConfirm that operating pressure does not exceed 232 PSIG.\u003c\/li\u003e\n\u003cli\u003eConfirm that ambient temperature remains between 41°F and 113°F.\u003c\/li\u003e\n\u003cli\u003eProvide a 115V single-phase, 60 Hz electrical supply.\u003c\/li\u003e\n\u003cli\u003eVerify that the electrical circuit meets the dryer’s nameplate requirements.\u003c\/li\u003e\n\u003cli\u003eUse properly sized 1-inch compressed-air piping.\u003c\/li\u003e\n\u003cli\u003eConfirm the correct compressed-air flow direction.\u003c\/li\u003e\n\u003cli\u003eKeep the condenser and ventilation openings clear.\u003c\/li\u003e\n\u003cli\u003ePrevent heated exhaust air from recirculating into the dryer.\u003c\/li\u003e\n\u003cli\u003eRoute the electronic drain discharge to an approved condensate collection or treatment system.\u003c\/li\u003e\n\u003cli\u003eProvide isolation valves to simplify future maintenance.\u003c\/li\u003e\n\u003cli\u003eAvoid unnecessary piping restrictions at the inlet and outlet.\u003c\/li\u003e\n\u003cli\u003eSupport external piping so its weight is not carried by the dryer connections.\u003c\/li\u003e\n\u003cli\u003eMaintain the manufacturer’s recommended service clearances.\u003c\/li\u003e\n\u003cli\u003eCheck the compressed-air system for leaks after installation.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eInstallation should be completed according to the supplied operating instructions and all applicable electrical, plumbing, and safety codes.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eRoutine Maintenance\u003c\/h2\u003e\n\u003cp\u003eRoutine inspection helps maintain moisture removal, cooling performance, and dependable dryer operation.\u003c\/p\u003e\n\u003cp\u003eTypical maintenance includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVerify that the electronic condensate drain is operating.\u003c\/li\u003e\n\u003cli\u003eInspect the drain discharge line for restrictions.\u003c\/li\u003e\n\u003cli\u003eKeep the condenser and ventilation openings clean.\u003c\/li\u003e\n\u003cli\u003eRemove accumulated dust and debris from cooling surfaces.\u003c\/li\u003e\n\u003cli\u003eCheck the dryer for unusual noise or vibration.\u003c\/li\u003e\n\u003cli\u003eInspect compressed-air fittings for leaks.\u003c\/li\u003e\n\u003cli\u003eVerify that inlet-air temperature remains within the rated limit.\u003c\/li\u003e\n\u003cli\u003eConfirm that ambient temperature remains within the allowable range.\u003c\/li\u003e\n\u003cli\u003eInspect electrical wiring and connections.\u003c\/li\u003e\n\u003cli\u003eCheck for excessive pressure drop through the dryer.\u003c\/li\u003e\n\u003cli\u003eFollow the maintenance instructions supplied with the unit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eMaintenance frequency can vary based on operating hours, dust levels, ambient temperature, humidity, and compressor operating conditions.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eBasic Troubleshooting\u003c\/h2\u003e\n\u003ch3\u003eWater Is Present Downstream\u003c\/h3\u003e\n\u003cp\u003eCheck the electronic drain, drain discharge line, inlet-air temperature, airflow demand, ambient temperature, operating pressure, and dryer ventilation.\u003c\/p\u003e\n\u003cp\u003eThe dryer may be undersized if actual operating conditions exceed its rated capacity.\u003c\/p\u003e\n\u003ch3\u003eElectronic Drain Does Not Discharge\u003c\/h3\u003e\n\u003cp\u003eCheck the drain’s electrical connection, timer operation, isolation valve, discharge tubing, and condensate outlet for blockages.\u003c\/p\u003e\n\u003ch3\u003eDryer Does Not Start\u003c\/h3\u003e\n\u003cp\u003eCheck the electrical outlet, circuit protection, power connection, dryer switch, and incoming voltage.\u003c\/p\u003e\n\u003ch3\u003eDryer Runs but Does Not Remove Moisture\u003c\/h3\u003e\n\u003cp\u003eVerify that the refrigeration system is operating, the condenser is clean, the condensate drain is functioning, and inlet conditions remain within the dryer’s rated limits.\u003c\/p\u003e\n\u003ch3\u003eExcessive Pressure Drop\u003c\/h3\u003e\n\u003cp\u003eInspect the compressed-air piping, valves, fittings, heat exchanger, and downstream air-treatment components for restrictions.\u003c\/p\u003e\n\u003ch3\u003eDryer Shuts Down or Runs Hot\u003c\/h3\u003e\n\u003cp\u003eCheck the ambient temperature, ventilation clearance, condenser cleanliness, and whether heated exhaust air is recirculating into the dryer.\u003c\/p\u003e\n\u003ch3\u003eExcessive Condensate in the Air System\u003c\/h3\u003e\n\u003cp\u003eConfirm that the air receiver is draining properly and that the dryer is installed and sized correctly for the compressor’s airflow and discharge temperature.\u003c\/p\u003e\n\u003cp\u003eRefrigeration-system repairs, electrical repairs, internal pressure-system repairs, and major service should be completed by qualified personnel.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eFrequently Asked Questions\u003c\/h1\u003e\n\u003ch2\u003eWhat is the rated capacity of the CPXHT50?\u003c\/h2\u003e\n\u003cp\u003eThe CPXHT50 is rated for \u003cstrong\u003e50 SCFM at 100 PSIG\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat is the manufacturer part number?\u003c\/h2\u003e\n\u003cp\u003eThe manufacturer part number is \u003cstrong\u003e4102003869\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat makes this a high-temperature dryer?\u003c\/h2\u003e\n\u003cp\u003eThe CPXHT50 can accept compressed-air inlet temperatures up to \u003cstrong\u003e180°F\u003c\/strong\u003e, allowing it to work with many reciprocating compressor systems without a separate aftercooler.\u003c\/p\u003e\n\u003ch2\u003eWhat size compressor is the CPXHT50 designed for?\u003c\/h2\u003e\n\u003cp\u003eIt is recommended for many \u003cstrong\u003e10 to 15 HP reciprocating air compressors\u003c\/strong\u003e, provided the compressor’s actual airflow and operating conditions remain within the dryer’s capacity.\u003c\/p\u003e\n\u003ch2\u003eWhat pressure dew point does it provide?\u003c\/h2\u003e\n\u003cp\u003eThe CPXHT50 provides a pressure dew point of approximately \u003cstrong\u003e50°F ± 2°F\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eDoes the dryer include a moisture separator?\u003c\/h2\u003e\n\u003cp\u003eYes. The CPXHT50 includes an integrated moisture separator.\u003c\/p\u003e\n\u003ch2\u003eDoes it include an automatic condensate drain?\u003c\/h2\u003e\n\u003cp\u003eYes. The dryer includes an electronic condensate drain that automatically discharges collected moisture.\u003c\/p\u003e\n\u003ch2\u003eWhat electrical service is required?\u003c\/h2\u003e\n\u003cp\u003eThe CPXHT50 requires \u003cstrong\u003e115V single-phase, 60 Hz electrical power\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat size are the air connections?\u003c\/h2\u003e\n\u003cp\u003eThe dryer uses \u003cstrong\u003e1-inch NPT inlet and outlet connections\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat is the maximum operating pressure?\u003c\/h2\u003e\n\u003cp\u003eThe maximum working pressure is \u003cstrong\u003e232 PSIG\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat is the allowable ambient temperature range?\u003c\/h2\u003e\n\u003cp\u003eThe dryer is designed for ambient temperatures between \u003cstrong\u003e41°F and 113°F\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat refrigerant does the CPXHT50 use?\u003c\/h2\u003e\n\u003cp\u003eThe CPXHT50 uses \u003cstrong\u003eR-404A refrigerant\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eDoes this dryer remove oil?\u003c\/h2\u003e\n\u003cp\u003eThe refrigerated dryer primarily removes moisture. Additional coalescing filtration may be needed to remove fine oil aerosols.\u003c\/p\u003e\n\u003ch2\u003eDoes the CPXHT50 replace an aftercooler?\u003c\/h2\u003e\n\u003cp\u003eIts high-temperature design can eliminate the need for a separate aftercooler in properly sized applications with inlet temperatures up to 180°F.\u003c\/p\u003e\n\u003ch2\u003eCan this dryer be used for automotive painting?\u003c\/h2\u003e\n\u003cp\u003eYes, provided it is properly sized. Paint applications may also require coalescing and point-of-use air treatment depending on the required finish quality.\u003c\/p\u003e\n\u003ch2\u003eWhere should the condensate drain discharge be routed?\u003c\/h2\u003e\n\u003cp\u003eCondensate should be routed to an appropriate collection or oil-water separation system according to applicable regulations.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eWhy Buy from Compressed Air Advisors Online?\u003c\/h2\u003e\n\u003cp\u003eCompressed Air Advisors Online provides knowledgeable compressed-air equipment selection, system guidance, premium industrial products, and nationwide delivery.\u003c\/p\u003e\n\u003cp\u003eOur team can help determine whether the Chicago Pneumatic CPXHT50 provides the correct capacity, inlet-temperature rating, operating pressure, connections, and electrical configuration for your compressed-air system.\u003c\/p\u003e\n\u003cp\u003eWhen you need dependable air-treatment equipment backed by practical compressed-air knowledge, Compressed Air Advisors Online is your compressed-air partner.\u003c\/p\u003e","brand":"Chicago Pneumatic","offers":[{"title":"Default Title","offer_id":46090035822662,"sku":"4102003869","price":3532.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0014\/6237\/0374\/products\/cpxht25.jpg?v=1646424665","url":"https:\/\/www.compressedairadvisors.com\/products\/chicago-pneumatic-cpxht50-high-temperature-dryer-4102003869","provider":"Compressed Air Advisors Online, Inc. ","version":"1.0","type":"link"}