{"product_id":"chicago-pneumatic-qrs-10-150-tm-4152023171","title":"Chicago Pneumatic QRS 10 150 TM 10 HP Rotary Screw Air Compressor, 120-Gallon Tank - PN 4152023171","description":"\u003ch1 class=\"PDq2pG_selectionAnchorContainer\"\u003eChicago Pneumatic QRS 10 150 TM 10 HP Rotary Screw Air Compressor, 120-Gallon Tank - PN 4152023171\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003ch2\u003eQuiet, Continuous-Duty Compressed Air in a Complete Tank-Mounted Package\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eChicago Pneumatic QRS 10 150 TM Rotary Screw Air Compressor, part number 4152023171\u003c\/strong\u003e, is a complete tank-mounted compressed-air package engineered for dependable performance, quiet operation, and continuous-duty use.\u003c\/p\u003e\n\u003cp\u003ePowered by a \u003cstrong\u003e10 HP motor\u003c\/strong\u003e, this fixed-speed rotary screw compressor delivers \u003cstrong\u003e31.2 ACFM at 150 PSIG\u003c\/strong\u003e and is mounted on a \u003cstrong\u003e120-gallon ASME air receiver tank\u003c\/strong\u003e. The large receiver provides compressed-air storage, helps stabilize system pressure, and supports short periods of increased air demand.\u003c\/p\u003e\n\u003cp\u003eThe Chicago Pneumatic QRS, or Quiet Rotary Screw, Series uses a single-stage, air-cooled, oil-injected rotary screw design. The package includes the rotary screw airend, main drive motor, air and oil systems, filtration components, oil cooler, aftercooler, cooling fan, belt-drive system, electronic controller, and receiver tank.\u003c\/p\u003e\n\u003cp\u003eUnlike a traditional reciprocating compressor, the QRS 10 provides smooth, pulse-free airflow with reduced vibration and a sound level of approximately \u003cstrong\u003e65 dBA\u003c\/strong\u003e. Its enclosed design makes it an excellent choice for automotive shops, tire stores, maintenance facilities, body shops, paint shops, woodworking operations, fabrication facilities, and light industrial applications.\u003c\/p\u003e\n\u003cp\u003eThe tri-voltage motor can be configured for \u003cstrong\u003e208, 230, or 460-volt three-phase electrical service\u003c\/strong\u003e, allowing the compressor to accommodate many common commercial and industrial power systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer Part Number: 4152023171\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eKey Features and Benefits\u003c\/h2\u003e\n\u003ch3\u003e31.2 ACFM at 150 PSIG\u003c\/h3\u003e\n\u003cp\u003eDelivers higher-pressure compressed air for pneumatic tools, automotive equipment, production machinery, and other applications requiring operating pressures up to 150 PSIG.\u003c\/p\u003e\n\u003ch3\u003e10 HP Fixed-Speed Rotary Screw Compressor\u003c\/h3\u003e\n\u003cp\u003eThe fixed-speed design provides consistent compressor output for facilities with steady or predictable compressed-air demand.\u003c\/p\u003e\n\u003ch3\u003eContinuous-Duty Operation\u003c\/h3\u003e\n\u003cp\u003eThe oil-injected rotary screw airend is designed for continuous-duty operation when the compressor is properly sized, installed, ventilated, and maintained.\u003c\/p\u003e\n\u003ch3\u003e120-Gallon ASME Air Receiver Tank\u003c\/h3\u003e\n\u003cp\u003eThe included receiver provides valuable compressed-air storage, helps reduce pressure fluctuations, and supports short periods of increased air demand.\u003c\/p\u003e\n\u003ch3\u003eComplete Tank-Mounted Package\u003c\/h3\u003e\n\u003cp\u003eThe compressor and receiver are assembled into one compact package, reducing installation space and eliminating the need to purchase a separate air tank.\u003c\/p\u003e\n\u003ch3\u003eQuiet Enclosed Design\u003c\/h3\u003e\n\u003cp\u003eThe low-sound enclosure limits operating noise to approximately 65 dBA, making the compressor significantly quieter than many open-frame reciprocating compressors.\u003c\/p\u003e\n\u003ch3\u003eES4000 Basic Controller\u003c\/h3\u003e\n\u003cp\u003eThe electronic controller provides straightforward monitoring and operation, including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePressure and temperature readings\u003c\/li\u003e\n\u003cli\u003eRunning and loaded-hour tracking\u003c\/li\u003e\n\u003cli\u003eService warnings\u003c\/li\u003e\n\u003cli\u003eElement outlet temperature monitoring\u003c\/li\u003e\n\u003cli\u003eWarning and shutdown alarms\u003c\/li\u003e\n\u003cli\u003eIntelligent shutdown\u003c\/li\u003e\n\u003cli\u003eAutomatic restart capability after a voltage interruption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eController settings and automatic restart features should be configured according to facility safety requirements.\u003c\/p\u003e\n\u003ch3\u003eTri-Voltage Three-Phase Motor\u003c\/h3\u003e\n\u003cp\u003eThe motor can be configured for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e208 volts, three phase\u003c\/li\u003e\n\u003cli\u003e230 volts, three phase\u003c\/li\u003e\n\u003cli\u003e460 volts, three phase\u003c\/li\u003e\n\u003cli\u003e60 Hz operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFinal voltage configuration and electrical installation should be completed by a qualified electrician.\u003c\/p\u003e\n\u003ch3\u003eBelt-Drive System\u003c\/h3\u003e\n\u003cp\u003eThe belt-drive design provides reliable power transfer between the motor and rotary screw airend while allowing straightforward inspection and routine drive maintenance.\u003c\/p\u003e\n\u003ch3\u003eIntegrated Aftercooler\u003c\/h3\u003e\n\u003cp\u003eThe built-in aftercooler reduces compressed-air discharge temperature and helps condense moisture before the air enters the receiver tank and downstream air-treatment equipment.\u003c\/p\u003e\n\u003ch3\u003eSpin-On Service Components\u003c\/h3\u003e\n\u003cp\u003eSpin-on oil filter and air-oil separator components simplify routine maintenance and help reduce service downtime.\u003c\/p\u003e\n\u003ch3\u003eVibration-Isolated Assembly\u003c\/h3\u003e\n\u003cp\u003eInternal vibration isolation helps reduce vibration transferred to the receiver tank, floor, and connected piping system.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eStandard Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eLow-sound enclosure\u003c\/li\u003e\n\u003cli\u003eContinuous-duty operating capability\u003c\/li\u003e\n\u003cli\u003eFixed-speed operation\u003c\/li\u003e\n\u003cli\u003eLoad\/no-load control with timed shutdown\u003c\/li\u003e\n\u003cli\u003eSingle-stage rotary screw airend\u003c\/li\u003e\n\u003cli\u003eOil-injected compression system\u003c\/li\u003e\n\u003cli\u003eAir-cooled design\u003c\/li\u003e\n\u003cli\u003eBelt-drive transmission\u003c\/li\u003e\n\u003cli\u003eES4000 Basic controller\u003c\/li\u003e\n\u003cli\u003eIntegrated aftercooler\u003c\/li\u003e\n\u003cli\u003eSpin-on oil filter\u003c\/li\u003e\n\u003cli\u003eSpin-on air-oil separator\u003c\/li\u003e\n\u003cli\u003eOil sight glass\u003c\/li\u003e\n\u003cli\u003eIntegrated oil cooler\u003c\/li\u003e\n\u003cli\u003eCooling fan\u003c\/li\u003e\n\u003cli\u003eEmergency-stop control\u003c\/li\u003e\n\u003cli\u003eUL, cUL, and CSA-approved control panel\u003c\/li\u003e\n\u003cli\u003eNEMA 1 electrical protection\u003c\/li\u003e\n\u003cli\u003eVibration-isolated compressor assembly\u003c\/li\u003e\n\u003cli\u003eTri-voltage three-phase motor\u003c\/li\u003e\n\u003cli\u003e120-gallon ASME receiver tank\u003c\/li\u003e\n\u003cli\u003eTank-mounted configuration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eChicago Pneumatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eQRS 10 150 TM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer Part Number\u003c\/td\u003e\n\u003ctd\u003e4152023171\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eOil-injected rotary screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Type\u003c\/td\u003e\n\u003ctd\u003eFixed speed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Type\u003c\/td\u003e\n\u003ctd\u003eBelt drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompression Stages\u003c\/td\u003e\n\u003ctd\u003eSingle stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Output\u003c\/td\u003e\n\u003ctd\u003e10 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Airflow\u003c\/td\u003e\n\u003ctd\u003e31.2 ACFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operating Pressure\u003c\/td\u003e\n\u003ctd\u003e150 PSIG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReceiver Tank Capacity\u003c\/td\u003e\n\u003ctd\u003e120 gallons\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReceiver Certification\u003c\/td\u003e\n\u003ctd\u003eASME\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Configuration\u003c\/td\u003e\n\u003ctd\u003eTank mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e208-230\/460V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eThree phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Method\u003c\/td\u003e\n\u003ctd\u003eAir cooled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eController\u003c\/td\u003e\n\u003ctd\u003eES4000 Basic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproximate Sound Level\u003c\/td\u003e\n\u003ctd\u003e65 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated Aftercooler\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated Refrigerated Dryer\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Protection\u003c\/td\u003e\n\u003ctd\u003eNEMA 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003ch2\u003eRecommended Applications\u003c\/h2\u003e\n\u003cp\u003eThe Chicago Pneumatic QRS 10 150 TM is well suited for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAutomotive repair shops\u003c\/li\u003e\n\u003cli\u003eTire shops\u003c\/li\u003e\n\u003cli\u003eFleet maintenance facilities\u003c\/li\u003e\n\u003cli\u003eAutomotive dealerships\u003c\/li\u003e\n\u003cli\u003eCollision repair and body shops\u003c\/li\u003e\n\u003cli\u003ePaint shops\u003c\/li\u003e\n\u003cli\u003eWoodworking and cabinet shops\u003c\/li\u003e\n\u003cli\u003eMetal fabrication facilities\u003c\/li\u003e\n\u003cli\u003eCNC machine support\u003c\/li\u003e\n\u003cli\u003ePneumatic assembly equipment\u003c\/li\u003e\n\u003cli\u003eIndustrial maintenance departments\u003c\/li\u003e\n\u003cli\u003eLight manufacturing\u003c\/li\u003e\n\u003cli\u003eSmall production facilities\u003c\/li\u003e\n\u003cli\u003eGeneral industrial compressed-air systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eAir Treatment Recommendations\u003c\/h2\u003e\n\u003cp\u003eThis compressor configuration \u003cstrong\u003edoes not include an integrated refrigerated air dryer\u003c\/strong\u003e. Although the built-in aftercooler helps reduce discharge temperature and condense moisture, additional air treatment is normally required to remove moisture, oil aerosols, and particulate contamination.\u003c\/p\u003e\n\u003cp\u003eDepending on the application, the compressed-air system may also require:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRefrigerated compressed-air dryer\u003c\/li\u003e\n\u003cli\u003eMoisture separator\u003c\/li\u003e\n\u003cli\u003eAutomatic receiver-tank drain\u003c\/li\u003e\n\u003cli\u003eGeneral-purpose particulate filter\u003c\/li\u003e\n\u003cli\u003eCoalescing oil-removal filter\u003c\/li\u003e\n\u003cli\u003ePressure regulator\u003c\/li\u003e\n\u003cli\u003eOil-water separator\u003c\/li\u003e\n\u003cli\u003ePoint-of-use filtration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications involving paint spraying, CNC equipment, instrumentation, or moisture-sensitive production processes normally require additional drying and filtration.\u003c\/p\u003e\n\u003cp\u003eThe dryer and filters should be sized according to compressor airflow, operating pressure, inlet-air temperature, ambient conditions, and required downstream air quality.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eInstallation Considerations\u003c\/h2\u003e\n\u003cp\u003eThe compressor should be installed indoors on a level, structurally adequate surface with sufficient space for ventilation, inspection, and routine maintenance.\u003c\/p\u003e\n\u003cp\u003eBefore installation:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eConfirm that the facility has 208, 230, or 460-volt three-phase electrical service.\u003c\/li\u003e\n\u003cli\u003eVerify that the total compressed-air demand is within the compressor’s 31.2 ACFM capacity.\u003c\/li\u003e\n\u003cli\u003eConfirm that piping and downstream equipment are rated for 150 PSIG operation.\u003c\/li\u003e\n\u003cli\u003eProvide adequate ventilation around the compressor.\u003c\/li\u003e\n\u003cli\u003ePrevent heated cooling air from recirculating into the compressor intake.\u003c\/li\u003e\n\u003cli\u003eInstall the required electrical disconnect and overcurrent protection.\u003c\/li\u003e\n\u003cli\u003eUse properly sized compressed-air piping.\u003c\/li\u003e\n\u003cli\u003eInstall a flexible connection between the compressor and rigid piping.\u003c\/li\u003e\n\u003cli\u003eConfirm that the receiver-tank drain is installed and operating correctly.\u003c\/li\u003e\n\u003cli\u003eMaintain the manufacturer’s recommended service clearances.\u003c\/li\u003e\n\u003cli\u003eVerify proper motor rotation during startup.\u003c\/li\u003e\n\u003cli\u003eComplete the manufacturer’s startup and warranty-registration requirements.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eElectrical and mechanical installation should be completed according to Chicago Pneumatic’s instructions and all applicable local codes.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eRoutine Maintenance\u003c\/h2\u003e\n\u003cp\u003eProper preventive maintenance helps protect compressor output, operating efficiency, temperature control, and equipment life.\u003c\/p\u003e\n\u003cp\u003eTypical maintenance includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCheck the compressor lubricant level.\u003c\/li\u003e\n\u003cli\u003eInspect and replace the intake air filter as needed.\u003c\/li\u003e\n\u003cli\u003eReplace the oil filter at the recommended interval.\u003c\/li\u003e\n\u003cli\u003eReplace the air-oil separator when required.\u003c\/li\u003e\n\u003cli\u003eUse Chicago Pneumatic-approved rotary screw compressor lubricant.\u003c\/li\u003e\n\u003cli\u003eInspect belt condition and tension.\u003c\/li\u003e\n\u003cli\u003eClean the oil cooler, aftercooler, and cooling surfaces.\u003c\/li\u003e\n\u003cli\u003eInspect hoses, fittings, valves, and electrical connections.\u003c\/li\u003e\n\u003cli\u003eCheck the receiver tank and condensate drain.\u003c\/li\u003e\n\u003cli\u003eTest the automatic condensate drain regularly.\u003c\/li\u003e\n\u003cli\u003eInspect the compressed-air system for leaks.\u003c\/li\u003e\n\u003cli\u003eKeep the compressor room clean and properly ventilated.\u003c\/li\u003e\n\u003cli\u003eFollow controller service warnings and maintenance intervals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eMaintenance intervals may vary depending on operating hours, ambient temperature, humidity, dust levels, and installation conditions.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eWarranty Information\u003c\/h2\u003e\n\u003cp\u003eChicago Pneumatic rotary screw compressors include a standard manufacturer’s warranty. An extended warranty of up to five years may be available when the compressor receives an authorized startup and is maintained according to Chicago Pneumatic requirements using approved fluids and genuine replacement parts.\u003c\/p\u003e\n\u003cp\u003eWarranty registration, authorized startup, maintenance documentation, lubricant requirements, and applicable coverage terms should be reviewed at the time of purchase.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eBasic Troubleshooting\u003c\/h2\u003e\n\u003ch3\u003eCompressor Cannot Maintain Pressure\u003c\/h3\u003e\n\u003cp\u003eCheck for compressed-air leaks, an open condensate drain, a restricted intake filter, incorrect pressure settings, or downstream equipment consuming more than the available 31.2 ACFM.\u003c\/p\u003e\n\u003ch3\u003eCompressor Runs Hot or Shuts Down\u003c\/h3\u003e\n\u003cp\u003eInspect room ventilation, ambient temperature, cooler cleanliness, lubricant level, intake restrictions, cooling-fan operation, and the possibility of heated air recirculating into the compressor intake.\u003c\/p\u003e\n\u003ch3\u003eCompressor Loads and Unloads Frequently\u003c\/h3\u003e\n\u003cp\u003eCheck for air leaks, rapidly changing air demand, incorrect pressure settings, an open condensate drain, or air demand that is too low or inconsistent for the compressor.\u003c\/p\u003e\n\u003ch3\u003eCompressor Does Not Start\u003c\/h3\u003e\n\u003cp\u003eCheck the electrical disconnect, incoming voltage, fuses, circuit protection, emergency-stop control, controller settings, and any active fault or shutdown condition.\u003c\/p\u003e\n\u003ch3\u003eCompressor Rotation Is Incorrect\u003c\/h3\u003e\n\u003cp\u003eThree-phase electrical connections may need to be corrected to achieve proper motor rotation. Disconnect power and have a qualified electrician correct the phase rotation before operating the compressor.\u003c\/p\u003e\n\u003ch3\u003eExcessive Moisture in the Air System\u003c\/h3\u003e\n\u003cp\u003eCheck the receiver-tank drain and condensate-removal equipment. Install a properly sized refrigerated air dryer, moisture separator, and filtration system when dry compressed air is required.\u003c\/p\u003e\n\u003ch3\u003eController Displays a Warning or Fault\u003c\/h3\u003e\n\u003cp\u003eRecord the warning or fault information and consult the operating manual. Do not repeatedly reset protective shutdowns without identifying and correcting the underlying cause.\u003c\/p\u003e\n\u003cp\u003eElectrical repairs, internal pressure-system repairs, belt adjustments, and controller repairs should be completed by qualified service personnel.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eFrequently Asked Questions\u003c\/h1\u003e\n\u003ch2\u003eHow much air does the Chicago Pneumatic QRS 10 150 TM produce?\u003c\/h2\u003e\n\u003cp\u003eThe Chicago Pneumatic QRS 10 150 TM delivers \u003cstrong\u003e31.2 ACFM at 150 PSIG\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat is the manufacturer part number?\u003c\/h2\u003e\n\u003cp\u003eThe manufacturer part number for this compressor is \u003cstrong\u003e4152023171\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat size air receiver tank is included?\u003c\/h2\u003e\n\u003cp\u003eThis compressor is mounted on a \u003cstrong\u003e120-gallon ASME air receiver tank\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eDoes this compressor include a refrigerated air dryer?\u003c\/h2\u003e\n\u003cp\u003eNo. This configuration does not include an integrated refrigerated air dryer. A separate dryer can be added when moisture removal is required.\u003c\/p\u003e\n\u003ch2\u003eDoes the compressor include an aftercooler?\u003c\/h2\u003e\n\u003cp\u003eYes. The integrated aftercooler helps reduce compressed-air discharge temperature and condense moisture before the air enters the receiver tank.\u003c\/p\u003e\n\u003ch2\u003eIs this a single-phase compressor?\u003c\/h2\u003e\n\u003cp\u003eNo. This model requires \u003cstrong\u003ethree-phase electrical power\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat voltages can this compressor use?\u003c\/h2\u003e\n\u003cp\u003eThe motor can be configured for \u003cstrong\u003e208, 230, or 460-volt three-phase power\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eCan this compressor operate continuously?\u003c\/h2\u003e\n\u003cp\u003eYes. The QRS rotary screw compressor is designed for continuous-duty applications when properly sized, installed, ventilated, and maintained.\u003c\/p\u003e\n\u003ch2\u003eHow loud is the Chicago Pneumatic QRS 10?\u003c\/h2\u003e\n\u003cp\u003eThe compressor has an approximate sound rating of \u003cstrong\u003e65 dBA\u003c\/strong\u003e, making it quieter than many open-frame reciprocating compressors.\u003c\/p\u003e\n\u003ch2\u003eWhat does the ES4000 Basic controller monitor?\u003c\/h2\u003e\n\u003cp\u003eThe controller displays operating pressure, temperature, running hours, loaded hours, service warnings, and system alarms. It also supports intelligent shutdown and automatic restart functionality.\u003c\/p\u003e\n\u003ch2\u003eCan this compressor operate automotive air tools?\u003c\/h2\u003e\n\u003cp\u003eYes, provided the combined air consumption of the tools operating at the same time does not exceed the compressor’s rated output of 31.2 ACFM.\u003c\/p\u003e\n\u003ch2\u003eCan this compressor be used for paint applications?\u003c\/h2\u003e\n\u003cp\u003eYes, when properly sized. Paint applications normally require a refrigerated air dryer, coalescing filtration, and appropriate point-of-use air treatment.\u003c\/p\u003e\n\u003ch2\u003eWhat is the advantage of a rotary screw compressor?\u003c\/h2\u003e\n\u003cp\u003eA rotary screw compressor provides smooth airflow, reduced vibration, quieter operation, and longer operating cycles compared with many traditional reciprocating compressors.\u003c\/p\u003e\n\u003ch2\u003eWhat is the difference between fixed-speed and variable-speed operation?\u003c\/h2\u003e\n\u003cp\u003eA fixed-speed compressor runs its motor at a constant speed and loads or unloads according to air demand. It is generally best suited for facilities with steady or predictable compressed-air usage.\u003c\/p\u003e\n\u003ch2\u003eHow do I determine whether 31.2 ACFM is enough?\u003c\/h2\u003e\n\u003cp\u003eAdd the CFM requirements of all tools and equipment that may operate simultaneously. Include additional capacity for compressed-air leaks, periods of peak demand, and future growth.\u003c\/p\u003e","brand":"Chicago Pneumatic","offers":[{"title":"Default Title","offer_id":12408726814790,"sku":"4152023171","price":11688.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0014\/6237\/0374\/products\/QRS_10_HP_TM_834e5a49-72b4-4423-9b5b-7f8f952d1581.jpg?v=1533087474","url":"https:\/\/www.compressedairadvisors.com\/products\/chicago-pneumatic-qrs-10-150-tm-4152023171","provider":"Compressed Air Advisors Online, Inc. ","version":"1.0","type":"link"}