{"product_id":"chicago-pneumatic-qrs-15-125-tm-4152023174","title":"Chicago Pneumatic QRS 15 125 TM 15 HP Rotary Screw Air Compressor, 120-Gallon Tank - PN 4152023174","description":"\u003ch1\u003e\u003cspan\u003eChicago Pneumatic QRS 15 125 TM 15 HP Rotary Screw Air Compressor, 120-Gallon Tank - PN 4152023174\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan\u003eQuiet, Continuous-Duty Compressed Air for Demanding Shop and Industrial Applications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eChicago Pneumatic QRS 15 125 TM Rotary Screw Air Compressor, part number 4152023174\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, is a complete tank-mounted compressed-air package engineered for dependable performance, quiet operation, and continuous-duty use.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePowered by a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e15 HP motor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, this fixed-speed rotary screw compressor delivers \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e54.9 ACFM at 125 PSIG\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and is mounted on a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e120-gallon horizontal ASME\/CRN air receiver tank\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. The large receiver provides valuable compressed-air storage, helps stabilize system pressure, and supports short periods of increased air demand.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Chicago Pneumatic QRS, or Quiet Rotary Screw, Series uses a single-stage, air-cooled, oil-injected rotary screw design. Its enclosed package provides smooth, pulse-free airflow with reduced vibration and an approximate sound level of \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e69 dBA\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, making it considerably quieter than many open-frame reciprocating compressors.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe QRS 15 125 TM is designed for automotive shops, tire stores, fleet maintenance facilities, fabrication operations, CNC equipment, woodworking businesses, manufacturing facilities, and other applications that require dependable compressed air throughout the workday.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe tri-voltage motor can be configured for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e208, 230, or 460-volt three-phase electrical service\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, allowing the compressor to accommodate many common commercial and industrial power systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eManufacturer Part Number: 4152023174\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features and Benefits\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan\u003e54.9 ACFM at 125 PSIG\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eDelivers the airflow required for multiple pneumatic tools, production machinery, automotive equipment, CNC machines, and other high-demand compressed-air applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e15 HP Fixed-Speed Rotary Screw Compressor\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe fixed-speed design provides consistent compressor output for facilities with steady or predictable compressed-air demand.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eContinuous-Duty Operation\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe oil-injected rotary screw airend is designed for continuous operating capability, eliminating the cool-down periods commonly associated with reciprocating compressors.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e120-Gallon Horizontal ASME\/CRN Receiver Tank\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe included receiver provides compressed-air storage, helps stabilize pressure, accommodates short periods of increased demand, and reduces rapid compressor cycling.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eComplete Tank-Mounted Package\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe compressor is factory mounted on the receiver tank, reducing installation complexity and eliminating the need to purchase and pipe a separate air receiver.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eQuiet Enclosed Design\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe low-sound enclosure limits compressor noise to approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e69 dBA\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, allowing installation closer to active work areas when proper ventilation and service clearances are provided.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eES4000 Connect Controller\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe ES4000 Connect controller provides straightforward monitoring and control of compressor operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eController features include:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003ePressure and temperature monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRunning-hour and working-hour tracking\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eService warnings\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eImproved start-and-stop logic\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCompressor operating-mode monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLeak-detection functionality\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eICONS connectivity for remote compressor monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eRemote-monitoring functionality may require network access, registration, and additional setup.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eTri-Voltage Three-Phase Motor\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe motor can be configured for:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e208 volts, three phase\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e230 volts, three phase\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e460 volts, three phase\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e60 Hz operation\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFinal voltage configuration and electrical installation should be completed by a qualified electrician.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eLoad\/No-Load Operation\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe compressor automatically loads and unloads according to system pressure and compressed-air demand, helping maintain stable airflow while reducing unnecessary loaded operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eSpin-On Service Components\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eSpin-on oil-filter and air-oil separator components help simplify preventive maintenance and reduce service downtime.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eVibration-Isolated Assembly\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eInternal vibration isolation helps reduce vibration transferred to the receiver tank, surrounding floor, and connected piping system.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eStandard Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e15 HP rotary screw compressor\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e54.9 ACFM at 125 PSIG\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLow-sound enclosure\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eApproximately 69 dBA sound level\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eContinuous operating capability\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFixed-speed operation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLoad\/no-load control\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSingle-stage rotary screw airend\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOil-injected compression system\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAir-cooled design\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eES4000 Connect controller\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e120-gallon horizontal ASME\/CRN receiver tank\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSpin-on oil filter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSpin-on air-oil separator\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIntegrated oil cooler\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCooling fan\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEmergency-stop control\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUL, cUL, and CSA-approved control panel\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eNEMA 1 electrical protection\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eVibration-isolated compressor assembly\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTri-voltage three-phase motor\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTank-mounted configuration\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eChicago Pneumatic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eQRS 15 125 TM\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer Part Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4152023174\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCompressor Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOil-injected rotary screw\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFixed speed\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCompression Stages\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSingle stage\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMotor Output\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15 HP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Airflow\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e54.9 ACFM\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Operating Pressure\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e125 PSIG\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum Full-Flow Pressure\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e132 PSIG\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eReceiver Tank Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e120 gallons\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eReceiver Certification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eASME\/CRN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTank Orientation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHorizontal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTank mounted\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e208-230\/460V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePhase\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eThree phase\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFrequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCooling Method\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAir cooled\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eController\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eES4000 Connect\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eApproximate Sound Level\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e69 dBA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated Refrigerated Dryer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNEMA 1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDuty Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eContinuous duty\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eApproximate Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e76.2 × 25.4 × 57.9 inches\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eApproximate Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e622 pounds\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eRecommended Applications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Chicago Pneumatic QRS 15 125 TM is well suited for:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eAutomotive repair shops\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTire shops\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFleet maintenance facilities\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAutomotive dealerships\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCollision repair and body shops\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePaint and finishing operations\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCNC machine shops\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMetal fabrication facilities\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eWoodworking and cabinet shops\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePneumatic assembly equipment\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePackaging facilities\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIndustrial maintenance departments\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLight manufacturing\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProduction facilities\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eGeneral industrial compressed-air systems\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eAir Treatment Recommendations\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis compressor configuration \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003edoes not include an integrated refrigerated air dryer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Compressed air naturally contains moisture, oil aerosols, and particulate contamination that may need to be removed before the air reaches downstream equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eDepending on the application, the compressed-air system may also require:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eRefrigerated compressed-air dryer\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMoisture separator\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAutomatic receiver-tank drain\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eGeneral-purpose particulate filter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHigh-efficiency coalescing filter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eActivated-carbon filter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePressure regulator\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOil-water separator\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePoint-of-use filtration\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePaint spraying, CNC machinery, instrumentation, automation equipment, and moisture-sensitive production processes normally require additional drying and filtration.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe dryer and filters should be sized according to compressor airflow, operating pressure, inlet temperature, ambient conditions, required air quality, and acceptable system pressure drop.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eInstallation Considerations\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe compressor should be installed indoors on a level, structurally adequate surface with sufficient space for ventilation, inspection, and routine maintenance.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBefore installation:\u003c\/span\u003e\u003c\/p\u003e\n\u003col start=\"1\"\u003e\n\u003cli\u003e\u003cspan\u003eConfirm that the facility has 208, 230, or 460-volt three-phase electrical service.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eVerify that total compressed-air demand is within the compressor’s 54.9 ACFM capacity.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eConfirm that piping, filters, dryers, and downstream equipment are rated for the operating pressure.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProvide adequate ventilation around the compressor.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePrevent heated cooling air from recirculating into the compressor intake.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInstall the required electrical disconnect and overcurrent protection.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUse properly sized compressed-air piping.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInstall a flexible connection between the compressor and rigid piping.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eVerify that the receiver-tank condensate drain is installed and operating correctly.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRoute oily condensate to an approved oil-water separator or disposal system.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMaintain the manufacturer’s recommended service clearances.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eVerify proper motor rotation during startup.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eComplete Chicago Pneumatic’s startup and warranty-registration requirements.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eElectrical and mechanical installation should be completed according to Chicago Pneumatic’s instructions and all applicable local codes.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eRoutine Maintenance\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eProper preventive maintenance helps protect compressor output, operating efficiency, temperature control, and equipment life.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eTypical maintenance includes:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eCheck the compressor lubricant level.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInspect and replace the intake air filter as needed.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eReplace the oil filter at the recommended interval.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eReplace the air-oil separator when required.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUse Chicago Pneumatic-approved rotary screw compressor lubricant.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eClean the oil cooler and cooling surfaces.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInspect hoses, fittings, valves, and electrical connections.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCheck the receiver tank and condensate drain.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTest the automatic condensate drain regularly.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInspect the compressed-air system for leaks.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eKeep the compressor room clean and properly ventilated.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFollow controller service warnings and maintenance intervals.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMaintain documentation required for extended-warranty coverage.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eMaintenance intervals may vary depending on operating hours, ambient temperature, humidity, dust levels, and installation conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eWarranty Information\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eChicago Pneumatic rotary screw compressors include a standard manufacturer’s warranty. Extended warranty coverage of up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efive years on qualifying major components\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e may be available when the compressor receives an authorized startup and is maintained according to Chicago Pneumatic requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eWarranty requirements may include:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eAuthorized compressor startup\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCompleted warranty registration\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUse of approved compressor lubricant\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUse of genuine Chicago Pneumatic maintenance parts\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMaintenance performed at the required intervals\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRetention of service and maintenance records\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eComplete warranty terms and requirements should be reviewed at the time of purchase.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eBasic Troubleshooting\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan\u003eCompressor Cannot Maintain Pressure\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eCheck for compressed-air leaks, an open condensate drain, a restricted intake filter, incorrect pressure settings, or downstream equipment consuming more than the available 54.9 ACFM.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eCompressor Runs Hot or Shuts Down\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eInspect room ventilation, ambient temperature, cooler cleanliness, lubricant level, intake restrictions, cooling-fan operation, and the possibility of heated cooling air recirculating into the compressor intake.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eCompressor Loads and Unloads Frequently\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eCheck for compressed-air leaks, rapidly changing air demand, incorrect pressure settings, an open condensate drain, or demand that is too low or inconsistent for the compressor.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eCompressor Does Not Start\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eCheck the electrical disconnect, incoming voltage, fuses, circuit protection, emergency-stop control, controller settings, and any active fault or shutdown condition.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eCompressor Rotation Is Incorrect\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThree-phase electrical connections may need to be corrected to achieve proper motor rotation. Disconnect power and have a qualified electrician correct the phase rotation before operating the compressor.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eExcessive Moisture Downstream\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eCheck the receiver-tank drain and condensate-removal equipment. Install a properly sized refrigerated dryer, moisture separator, and filtration system when dry compressed air is required.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eExcessive Pressure Drop\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eInspect compressed-air filters, piping size, isolation valves, regulators, and filter elements for restrictions or contamination.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eController Displays a Warning or Fault\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eRecord the warning or fault information and consult the operating manual. Do not repeatedly reset protective shutdowns without identifying and correcting the underlying cause.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eElectrical repairs, internal pressure-system repairs, controller repairs, and major compressor service should be completed by qualified service personnel.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch1\u003e\u003cspan\u003eFrequently Asked Questions\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan\u003eHow much air does the Chicago Pneumatic QRS 15 125 TM produce?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Chicago Pneumatic QRS 15 125 TM delivers \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e54.9 ACFM at 125 PSIG\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eWhat is the manufacturer part number?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe manufacturer part number for this compressor is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e4152023174\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eWhat size air receiver tank is included?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis compressor is mounted on a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e120-gallon horizontal ASME\/CRN air receiver tank\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eDoes this compressor include a refrigerated air dryer?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eNo. This configuration does not include an integrated refrigerated air dryer. A separate dryer can be added when moisture removal is required.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eIs this a single-phase compressor?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eNo. This model requires \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ethree-phase electrical power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eWhat voltages can this compressor use?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe motor can be configured for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e208, 230, or 460-volt three-phase power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eCan this compressor operate continuously?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eYes. The QRS rotary screw compressor is designed for continuous-duty applications when properly sized, installed, ventilated, and maintained.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eHow loud is the Chicago Pneumatic QRS 15?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe compressor has an approximate sound rating of \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e69 dBA\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, making it quieter than many traditional open-frame reciprocating compressors.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eWhat does the ES4000 Connect controller monitor?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe controller tracks compressor pressure, temperature, running hours, working hours, operating mode, and service requirements. It also supports leak detection and remote monitoring through Chicago Pneumatic’s ICONS technology.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eCan this compressor operate multiple air tools?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eYes, provided the combined air consumption of the tools and equipment operating at the same time does not exceed the compressor’s rated output of 54.9 ACFM.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eIs this compressor suitable for CNC equipment?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eYes. Its continuous-duty performance, stable airflow, large receiver tank, and 54.9 ACFM output make it a strong option for properly sized CNC and manufacturing applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eCan this compressor be used for paint applications?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eYes, when properly sized. Paint applications normally require a refrigerated air dryer, coalescing filtration, and appropriate point-of-use air treatment.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eWhy choose a rotary screw compressor instead of a piston compressor?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA rotary screw compressor provides continuous-duty capability, smoother airflow, reduced vibration, quieter operation, and longer operating cycles compared with many traditional reciprocating compressors.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eWhat is the difference between fixed-speed and variable-speed operation?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA fixed-speed compressor runs its motor at a constant speed and loads or unloads according to air demand. It is generally best suited for facilities with steady or predictable compressed-air usage.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eHow do I determine whether 54.9 ACFM is enough?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAdd the CFM requirements of all tools and equipment that may operate simultaneously. Include additional capacity for compressed-air leaks, periods of peak demand, and future growth.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eWhy Buy from Compressed Air Advisors Online?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eCompressed Air Advisors Online provides more than equipment in a box. Our team offers knowledgeable product-selection assistance, compressed-air system guidance, premium industrial manufacturers, and nationwide delivery.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eWe can help determine whether the Chicago Pneumatic QRS 15 125 TM provides the correct airflow, pressure, electrical configuration, storage capacity, and air quality for your application.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWhen you need dependable compressed-air equipment supported by real-world application knowledge, Compressed Air Advisors Online is your compressed-air partner.\u003c\/span\u003e\u003c\/p\u003e","brand":"Chicago Pneumatic","offers":[{"title":"Default Title","offer_id":12405722677318,"sku":"4152023174","price":12452.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0014\/6237\/0374\/files\/QRS_15_HP_TM_1.jpg?v=1743517600","url":"https:\/\/www.compressedairadvisors.com\/products\/chicago-pneumatic-qrs-15-125-tm-4152023174","provider":"Compressed Air Advisors Online, Inc. ","version":"1.0","type":"link"}