{"product_id":"chicago-pneumatic-qrs-15d-150-tm-4152023183","title":"Chicago Pneumatic QRS 15D-150 TM 15 HP Rotary Screw Air Compressor with Dryer, 120-Gallon Tank - PN 4152023183","description":"\u003ch1 class=\"PDq2pG_selectionAnchorContainer\"\u003eChicago Pneumatic QRS 15D-150 TM 15 HP Rotary Screw Air Compressor with Dryer, 120-Gallon Tank - PN 4152023183\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003ch2\u003eHigh-Pressure Compressed Air System with an Integrated Refrigerated Dryer\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eChicago Pneumatic QRS 15D-150 TM Rotary Screw Air Compressor, part number 4152023183\u003c\/strong\u003e, is a complete tank-mounted compressed-air package engineered for dependable performance, quiet operation, and continuous-duty use at higher operating pressures.\u003c\/p\u003e\n\u003cp\u003ePowered by a \u003cstrong\u003e15 HP motor\u003c\/strong\u003e, this fixed-speed rotary screw compressor delivers \u003cstrong\u003e49.2 ACFM at 150 PSIG\u003c\/strong\u003e. The compressor, factory-installed refrigerated air dryer, and \u003cstrong\u003e120-gallon ASME air receiver tank\u003c\/strong\u003e are combined into one compact package, simplifying installation and reducing the floor space required for a complete compressed-air system.\u003c\/p\u003e\n\u003cp\u003eThe Chicago Pneumatic QRS, or Quiet Rotary Screw, Series uses a single-stage, air-cooled, oil-injected rotary screw design. Its enclosed package provides smooth, pulse-free airflow with reduced vibration and an approximate sound level of \u003cstrong\u003e69 dBA\u003c\/strong\u003e, making it considerably quieter than many open-frame reciprocating compressors. \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe integrated refrigerated dryer helps remove moisture from the compressed air before it enters the facility’s distribution system. This helps protect pneumatic tools, CNC machinery, automation components, paint systems, production equipment, and compressed-air piping from moisture-related corrosion and contamination.\u003c\/p\u003e\n\u003cp\u003eDesigned for facilities that need more operating pressure than a standard 125 PSI system can provide, the QRS 15D-150 TM is well suited for automotive service, tire shops, CNC machining, fabrication, manufacturing, fleet maintenance, and other demanding industrial applications.\u003c\/p\u003e\n\u003cp\u003eThe tri-voltage motor can be configured for \u003cstrong\u003e208, 230, or 460-volt three-phase electrical service\u003c\/strong\u003e, allowing the compressor to accommodate many common commercial and industrial power systems. \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer Part Number: 4152023183\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eKey Features and Benefits\u003c\/h2\u003e\n\u003ch3\u003e49.2 ACFM at 150 PSIG\u003c\/h3\u003e\n\u003cp\u003eDelivers dependable higher-pressure compressed air for pneumatic tools, automotive equipment, production machinery, CNC systems, and appropriately sized industrial applications.\u003c\/p\u003e\n\u003ch3\u003e15 HP Fixed-Speed Rotary Screw Compressor\u003c\/h3\u003e\n\u003cp\u003eThe fixed-speed design provides consistent compressor output for facilities with steady or predictable compressed-air demand.\u003c\/p\u003e\n\u003ch3\u003eContinuous-Duty Operation\u003c\/h3\u003e\n\u003cp\u003eThe oil-injected rotary screw airend is designed for continuous operating capability, eliminating the mandatory cool-down periods commonly associated with reciprocating compressors. \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eIntegrated Refrigerated Air Dryer\u003c\/h3\u003e\n\u003cp\u003eThe factory-installed refrigerated dryer cools the compressed air to help condense and remove moisture before it reaches the facility’s air distribution system.\u003c\/p\u003e\n\u003ch3\u003e120-Gallon ASME Air Receiver Tank\u003c\/h3\u003e\n\u003cp\u003eThe included receiver provides compressed-air storage, helps stabilize system pressure, supports short periods of increased demand, and reduces rapid compressor cycling.\u003c\/p\u003e\n\u003ch3\u003eComplete Three-in-One Package\u003c\/h3\u003e\n\u003cp\u003eThe QRS 15D-150 TM combines three essential compressed-air system components:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRotary screw air compressor\u003c\/li\u003e\n\u003cli\u003eRefrigerated compressed-air dryer\u003c\/li\u003e\n\u003cli\u003e120-gallon ASME air receiver tank\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis integrated design reduces installation complexity, minimizes external piping requirements, and saves valuable floor space.\u003c\/p\u003e\n\u003ch3\u003eHigh-Pressure Performance\u003c\/h3\u003e\n\u003cp\u003eThe 150 PSIG operating pressure supports pneumatic equipment and production machinery requiring more pressure than a standard 125 PSI compressed-air system can provide.\u003c\/p\u003e\n\u003ch3\u003eQuiet Enclosed Design\u003c\/h3\u003e\n\u003cp\u003eThe low-sound enclosure limits operating noise to approximately \u003cstrong\u003e69 dBA\u003c\/strong\u003e, allowing the compressor to be installed closer to active work areas when proper ventilation and service clearances are provided. \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eES4000 Electronic Controller\u003c\/h3\u003e\n\u003cp\u003eThe ES4000 electronic controller provides straightforward compressor monitoring and energy-saving operation.\u003c\/p\u003e\n\u003cp\u003eDepending on the production revision, controller functions may include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePressure and temperature readings\u003c\/li\u003e\n\u003cli\u003eRunning-hour tracking\u003c\/li\u003e\n\u003cli\u003eWorking-hour tracking\u003c\/li\u003e\n\u003cli\u003eService warnings\u003c\/li\u003e\n\u003cli\u003eElement outlet temperature monitoring\u003c\/li\u003e\n\u003cli\u003eWarning and shutdown alarms\u003c\/li\u003e\n\u003cli\u003eIntelligent shutdown\u003c\/li\u003e\n\u003cli\u003eAutomatic restart capability following a voltage interruption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe supplied operating manual and compressor serial number should be used to confirm the exact controller version and available functions. Automatic restart should be configured according to facility safety requirements. \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTri-Voltage Three-Phase Motor\u003c\/h3\u003e\n\u003cp\u003eThe motor can be configured for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e208 volts, three phase\u003c\/li\u003e\n\u003cli\u003e230 volts, three phase\u003c\/li\u003e\n\u003cli\u003e460 volts, three phase\u003c\/li\u003e\n\u003cli\u003e60 Hz operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFinal voltage configuration and electrical installation should be completed by a qualified electrician.\u003c\/p\u003e\n\u003ch3\u003eBelt-Drive System\u003c\/h3\u003e\n\u003cp\u003eThe belt-drive design provides reliable power transfer between the motor and rotary screw airend while allowing straightforward inspection and routine drive maintenance.\u003c\/p\u003e\n\u003ch3\u003eIntegrated Aftercooler\u003c\/h3\u003e\n\u003cp\u003eThe built-in aftercooler helps reduce compressed-air discharge temperature and condense moisture before the air reaches the refrigerated dryer and receiver tank. \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eSpin-On Service Components\u003c\/h3\u003e\n\u003cp\u003eSpin-on oil-filter and air-oil separator components help simplify preventive maintenance and reduce downtime during scheduled service. \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eVibration-Isolated Assembly\u003c\/h3\u003e\n\u003cp\u003eInternal vibration isolation helps reduce vibration transferred to the receiver tank, surrounding floor, and connected compressed-air piping.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eStandard Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e15 HP rotary screw compressor\u003c\/li\u003e\n\u003cli\u003e49.2 ACFM at 150 PSIG\u003c\/li\u003e\n\u003cli\u003eMaximum full-flow pressure of 157 PSIG\u003c\/li\u003e\n\u003cli\u003eIntegrated refrigerated air dryer\u003c\/li\u003e\n\u003cli\u003e120-gallon ASME air receiver tank\u003c\/li\u003e\n\u003cli\u003eTank-mounted configuration\u003c\/li\u003e\n\u003cli\u003eLow-sound enclosure\u003c\/li\u003e\n\u003cli\u003eApproximately 69 dBA sound level\u003c\/li\u003e\n\u003cli\u003eContinuous-duty operating capability\u003c\/li\u003e\n\u003cli\u003eFixed-speed operation\u003c\/li\u003e\n\u003cli\u003eLoad\/no-load control with timed shutdown\u003c\/li\u003e\n\u003cli\u003eSingle-stage rotary screw airend\u003c\/li\u003e\n\u003cli\u003eOil-injected compression system\u003c\/li\u003e\n\u003cli\u003eAir-cooled design\u003c\/li\u003e\n\u003cli\u003eBelt-drive transmission\u003c\/li\u003e\n\u003cli\u003eES4000 electronic controller\u003c\/li\u003e\n\u003cli\u003eIntegrated aftercooler\u003c\/li\u003e\n\u003cli\u003eSpin-on oil filter\u003c\/li\u003e\n\u003cli\u003eSpin-on air-oil separator\u003c\/li\u003e\n\u003cli\u003eIntegrated oil cooler\u003c\/li\u003e\n\u003cli\u003eCooling fan\u003c\/li\u003e\n\u003cli\u003eEmergency-stop control\u003c\/li\u003e\n\u003cli\u003eNEMA 1 electrical protection\u003c\/li\u003e\n\u003cli\u003eVibration-isolated compressor assembly\u003c\/li\u003e\n\u003cli\u003eTri-voltage three-phase motor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eChicago Pneumatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eQRS 15D-150 TM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer Part Number\u003c\/td\u003e\n\u003ctd\u003e4152023183\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eOil-injected rotary screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Type\u003c\/td\u003e\n\u003ctd\u003eFixed speed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Type\u003c\/td\u003e\n\u003ctd\u003eBelt drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompression Stages\u003c\/td\u003e\n\u003ctd\u003eSingle stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Output\u003c\/td\u003e\n\u003ctd\u003e15 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Airflow\u003c\/td\u003e\n\u003ctd\u003e49.2 ACFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operating Pressure\u003c\/td\u003e\n\u003ctd\u003e150 PSIG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Full-Flow Pressure\u003c\/td\u003e\n\u003ctd\u003e157 PSIG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReceiver Tank Capacity\u003c\/td\u003e\n\u003ctd\u003e120 gallons\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReceiver Certification\u003c\/td\u003e\n\u003ctd\u003eASME\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Configuration\u003c\/td\u003e\n\u003ctd\u003eTank mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e208-230\/460V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eThree phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Enclosure\u003c\/td\u003e\n\u003ctd\u003eTEFC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Method\u003c\/td\u003e\n\u003ctd\u003eAir cooled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eController\u003c\/td\u003e\n\u003ctd\u003eES4000 electronic controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproximate Sound Level\u003c\/td\u003e\n\u003ctd\u003e69 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated Aftercooler\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated Refrigerated Dryer\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Protection\u003c\/td\u003e\n\u003ctd\u003eNEMA 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDuty Rating\u003c\/td\u003e\n\u003ctd\u003eContinuous duty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproximate Dimensions\u003c\/td\u003e\n\u003ctd\u003e57 × 24 × 50 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe rated airflow, pressure, horsepower, maximum full-flow pressure, sound level, motor configuration, and approximate package dimensions are based on Chicago Pneumatic’s published QRS performance data. \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eRecommended Applications\u003c\/h2\u003e\n\u003cp\u003eThe Chicago Pneumatic QRS 15D-150 TM is well suited for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAutomotive repair facilities\u003c\/li\u003e\n\u003cli\u003eTire shops\u003c\/li\u003e\n\u003cli\u003eFleet maintenance departments\u003c\/li\u003e\n\u003cli\u003eAutomotive dealerships\u003c\/li\u003e\n\u003cli\u003eCNC machine shops\u003c\/li\u003e\n\u003cli\u003eMetal fabrication operations\u003c\/li\u003e\n\u003cli\u003eManufacturing facilities\u003c\/li\u003e\n\u003cli\u003eWoodworking and cabinet shops\u003c\/li\u003e\n\u003cli\u003ePaint and finishing operations\u003c\/li\u003e\n\u003cli\u003ePneumatic assembly equipment\u003c\/li\u003e\n\u003cli\u003ePackaging facilities\u003c\/li\u003e\n\u003cli\u003ePlastics-processing operations\u003c\/li\u003e\n\u003cli\u003eIndustrial maintenance departments\u003c\/li\u003e\n\u003cli\u003eAutomation equipment\u003c\/li\u003e\n\u003cli\u003eProduction machinery\u003c\/li\u003e\n\u003cli\u003eMulti-station pneumatic systems\u003c\/li\u003e\n\u003cli\u003eApplications requiring 150 PSI compressed air\u003c\/li\u003e\n\u003cli\u003eGeneral industrial compressed-air systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eChicago Pneumatic positions the QRS range for service and light-industrial applications, including tire shops, maintenance shops, paint shops, vehicle body shops, and automotive dealerships. \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eBenefits of 150 PSI Operation\u003c\/h2\u003e\n\u003cp\u003eA 150 PSIG rotary screw compressor provides additional pressure capacity for applications that cannot operate effectively on a standard 125 PSI compressed-air system.\u003c\/p\u003e\n\u003cp\u003ePotential benefits include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSupports higher-pressure pneumatic equipment\u003c\/li\u003e\n\u003cli\u003eProvides additional pressure for tire-service applications\u003c\/li\u003e\n\u003cli\u003eHelps compensate for pressure drop through dryers, filters, and piping\u003c\/li\u003e\n\u003cli\u003eSupports production machinery requiring elevated inlet pressure\u003c\/li\u003e\n\u003cli\u003eProvides additional pressure reserve during peak-demand periods\u003c\/li\u003e\n\u003cli\u003eAccommodates applications with long compressed-air piping runs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe compressor should not be operated at a higher pressure than the application requires. Higher system pressure increases energy consumption and compressed-air leakage, so the operating pressure should be matched to actual equipment requirements.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eBenefits of the Integrated Refrigerated Dryer\u003c\/h2\u003e\n\u003cp\u003eAtmospheric air naturally contains water vapor. Compressing the air concentrates that moisture, which can condense into liquid water as the air cools inside the receiver tank and distribution piping.\u003c\/p\u003e\n\u003cp\u003eThe integrated refrigerated dryer helps reduce moisture in the compressed-air system and provides several potential benefits:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHelps protect pneumatic tools from internal corrosion\u003c\/li\u003e\n\u003cli\u003eReduces water accumulation inside compressed-air piping\u003c\/li\u003e\n\u003cli\u003eHelps protect CNC machinery and automation components\u003c\/li\u003e\n\u003cli\u003eImproves air quality for paint and finishing applications\u003c\/li\u003e\n\u003cli\u003eReduces moisture-related equipment maintenance\u003c\/li\u003e\n\u003cli\u003eHelps prevent water contamination at points of use\u003c\/li\u003e\n\u003cli\u003eSimplifies installation compared with a separately installed dryer\u003c\/li\u003e\n\u003cli\u003eReduces external piping and electrical connections\u003c\/li\u003e\n\u003cli\u003eHelps protect downstream filters and regulators\u003c\/li\u003e\n\u003cli\u003eSupports more consistent production-air quality\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe dryer must be properly ventilated, drained, and maintained to provide dependable moisture removal.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eAdditional Air Treatment Recommendations\u003c\/h2\u003e\n\u003cp\u003eAlthough this compressor includes a refrigerated air dryer, additional filtration may still be required to remove condensed moisture, particulate contamination, and oil aerosols.\u003c\/p\u003e\n\u003cp\u003eDepending on the application, the compressed-air system may also require:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMoisture separator\u003c\/li\u003e\n\u003cli\u003eAutomatic receiver-tank drain\u003c\/li\u003e\n\u003cli\u003eAutomatic dryer condensate drain\u003c\/li\u003e\n\u003cli\u003eGeneral-purpose particulate filter\u003c\/li\u003e\n\u003cli\u003eHigh-efficiency coalescing filter\u003c\/li\u003e\n\u003cli\u003eActivated-carbon filter\u003c\/li\u003e\n\u003cli\u003ePressure regulator\u003c\/li\u003e\n\u003cli\u003eOil-water separator\u003c\/li\u003e\n\u003cli\u003ePoint-of-use filtration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003ePaint spraying, instrumentation, sensitive CNC machinery, food-related applications, and other critical processes may require higher levels of filtration or a lower pressure dew point than a standard refrigerated dryer can provide.\u003c\/p\u003e\n\u003cp\u003eFilters should be sized according to compressor airflow, operating pressure, inlet temperature, required air quality, and acceptable pressure drop.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eInstallation Considerations\u003c\/h2\u003e\n\u003cp\u003eThe compressor should be installed indoors on a level, structurally adequate surface with sufficient space for ventilation, inspection, and routine maintenance.\u003c\/p\u003e\n\u003cp\u003eBefore installation:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eConfirm that the facility has 208, 230, or 460-volt three-phase electrical service.\u003c\/li\u003e\n\u003cli\u003eVerify that total compressed-air demand is within the compressor’s 49.2 ACFM capacity.\u003c\/li\u003e\n\u003cli\u003eConfirm that piping, filters, and downstream equipment are rated for 150 PSIG operation.\u003c\/li\u003e\n\u003cli\u003eProvide adequate ventilation around both the compressor and refrigerated dryer.\u003c\/li\u003e\n\u003cli\u003ePrevent heated cooling air from recirculating into the compressor or dryer intake.\u003c\/li\u003e\n\u003cli\u003eInstall the required electrical disconnect and overcurrent protection.\u003c\/li\u003e\n\u003cli\u003eConfirm the electrical requirements for the complete compressor-and-dryer package.\u003c\/li\u003e\n\u003cli\u003eUse properly sized compressed-air piping.\u003c\/li\u003e\n\u003cli\u003eInstall a flexible connection between the compressor and rigid piping.\u003c\/li\u003e\n\u003cli\u003eVerify that the receiver-tank and dryer condensate drains are installed and operating correctly.\u003c\/li\u003e\n\u003cli\u003eRoute oily condensate to an approved oil-water separator or disposal system.\u003c\/li\u003e\n\u003cli\u003eMaintain the manufacturer’s recommended service clearances.\u003c\/li\u003e\n\u003cli\u003eVerify proper motor rotation during startup.\u003c\/li\u003e\n\u003cli\u003eConfigure the controller according to facility operating and safety requirements.\u003c\/li\u003e\n\u003cli\u003eComplete Chicago Pneumatic’s startup and warranty-registration requirements.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eElectrical and mechanical installation should be completed according to Chicago Pneumatic’s instructions and all applicable local codes.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eRoutine Maintenance\u003c\/h2\u003e\n\u003cp\u003eProper preventive maintenance helps protect compressor output, dryer performance, operating efficiency, temperature control, and equipment life.\u003c\/p\u003e\n\u003ch3\u003eTypical Compressor Maintenance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCheck the compressor lubricant level.\u003c\/li\u003e\n\u003cli\u003eInspect and replace the intake air filter as needed.\u003c\/li\u003e\n\u003cli\u003eReplace the oil filter at the recommended interval.\u003c\/li\u003e\n\u003cli\u003eReplace the air-oil separator when required.\u003c\/li\u003e\n\u003cli\u003eUse Chicago Pneumatic-approved rotary screw compressor lubricant.\u003c\/li\u003e\n\u003cli\u003eInspect belt condition, alignment, and tension.\u003c\/li\u003e\n\u003cli\u003eClean the oil cooler, aftercooler, and cooling surfaces.\u003c\/li\u003e\n\u003cli\u003eInspect hoses, fittings, valves, and electrical connections.\u003c\/li\u003e\n\u003cli\u003eCheck the receiver tank and condensate drain.\u003c\/li\u003e\n\u003cli\u003eInspect the compressed-air system for leaks.\u003c\/li\u003e\n\u003cli\u003eFollow controller service warnings and maintenance intervals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTypical Refrigerated-Dryer Maintenance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify that the dryer condensate drain is operating.\u003c\/li\u003e\n\u003cli\u003eClean the condenser and ventilation surfaces.\u003c\/li\u003e\n\u003cli\u003eInspect the dryer for excessive pressure drop.\u003c\/li\u003e\n\u003cli\u003eConfirm that inlet-air temperature remains within the dryer’s operating limits.\u003c\/li\u003e\n\u003cli\u003eCheck for dryer alarms or abnormal operating conditions.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate airflow around the dryer.\u003c\/li\u003e\n\u003cli\u003eInspect filters installed before and after the dryer.\u003c\/li\u003e\n\u003cli\u003eReplace filter elements at the recommended intervals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eMaintenance intervals may vary depending on operating hours, ambient temperature, humidity, dust levels, and installation conditions.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eWarranty Information\u003c\/h2\u003e\n\u003cp\u003eChicago Pneumatic rotary screw compressors include a standard manufacturer’s warranty. The QRS platform may be eligible for extended coverage of up to \u003cstrong\u003efive years\u003c\/strong\u003e when the compressor receives an authorized startup and is maintained with factory-authorized fluids and parts. \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eWarranty requirements may include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAuthorized compressor startup\u003c\/li\u003e\n\u003cli\u003eCompleted warranty registration\u003c\/li\u003e\n\u003cli\u003eUse of approved compressor lubricant\u003c\/li\u003e\n\u003cli\u003eUse of genuine Chicago Pneumatic maintenance parts\u003c\/li\u003e\n\u003cli\u003eMaintenance performed at the required intervals\u003c\/li\u003e\n\u003cli\u003eRequired oil analysis\u003c\/li\u003e\n\u003cli\u003eRetention of service and maintenance records\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eComplete warranty terms, dryer coverage, registration requirements, and maintenance obligations should be reviewed at the time of purchase.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eBasic Troubleshooting\u003c\/h2\u003e\n\u003ch3\u003eCompressor Cannot Maintain Pressure\u003c\/h3\u003e\n\u003cp\u003eCheck for compressed-air leaks, an open condensate drain, a restricted intake filter, incorrect pressure settings, or downstream equipment consuming more than the available 49.2 ACFM.\u003c\/p\u003e\n\u003ch3\u003eCompressor Runs Hot or Shuts Down\u003c\/h3\u003e\n\u003cp\u003eInspect room ventilation, ambient temperature, cooler cleanliness, lubricant level, intake restrictions, cooling-fan operation, and the possibility of heated air recirculating into the compressor intake.\u003c\/p\u003e\n\u003ch3\u003eCompressor Loads and Unloads Frequently\u003c\/h3\u003e\n\u003cp\u003eCheck for compressed-air leaks, rapidly changing air demand, incorrect pressure settings, an open condensate drain, or demand that is too low or inconsistent for the compressor.\u003c\/p\u003e\n\u003ch3\u003eCompressor Does Not Start\u003c\/h3\u003e\n\u003cp\u003eCheck the electrical disconnect, incoming voltage, fuses, circuit protection, emergency-stop control, controller settings, and any active fault or shutdown condition.\u003c\/p\u003e\n\u003ch3\u003eCompressor Rotation Is Incorrect\u003c\/h3\u003e\n\u003cp\u003eThree-phase electrical connections may need to be corrected to achieve proper motor rotation. Disconnect power and have a qualified electrician correct the phase rotation before operating the compressor.\u003c\/p\u003e\n\u003ch3\u003eExcessive Moisture Downstream\u003c\/h3\u003e\n\u003cp\u003eCheck dryer operation, the receiver-tank drain, dryer condensate drain, inlet-air temperature, ambient temperature, and airflow through the dryer. Confirm that system demand does not exceed the compressor or dryer capacity.\u003c\/p\u003e\n\u003ch3\u003eDryer Is Operating but Water Is Still Present\u003c\/h3\u003e\n\u003cp\u003eInspect automatic drains, downstream piping, receiver drainage, system operating conditions, and the possibility that moisture is entering from another section of the compressed-air system.\u003c\/p\u003e\n\u003ch3\u003eExcessive Pressure Drop\u003c\/h3\u003e\n\u003cp\u003eInspect the refrigerated dryer, compressed-air filters, piping size, isolation valves, regulators, and filter elements for restrictions or contamination.\u003c\/p\u003e\n\u003ch3\u003eDryer Does Not Start\u003c\/h3\u003e\n\u003cp\u003eCheck the dryer power supply, disconnect, operating switch, ventilation, alarm indicators, and condensate-drain system. Consult the supplied dryer manual before resetting an alarm.\u003c\/p\u003e\n\u003ch3\u003eController Displays a Warning or Fault\u003c\/h3\u003e\n\u003cp\u003eRecord the warning or fault information and consult the operating manual. Do not repeatedly reset protective shutdowns without identifying and correcting the underlying cause.\u003c\/p\u003e\n\u003cp\u003eElectrical repairs, refrigeration-system repairs, internal pressure-system repairs, belt adjustments, controller repairs, and major compressor service should be completed by qualified service personnel.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eFrequently Asked Questions\u003c\/h1\u003e\n\u003ch2\u003eHow much air does the Chicago Pneumatic QRS 15D-150 TM produce?\u003c\/h2\u003e\n\u003cp\u003eThe Chicago Pneumatic QRS 15D-150 TM delivers \u003cstrong\u003e49.2 ACFM at 150 PSIG\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat is the manufacturer part number?\u003c\/h2\u003e\n\u003cp\u003eThe manufacturer part number for this compressor is \u003cstrong\u003e4152023183\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat size air receiver tank is included?\u003c\/h2\u003e\n\u003cp\u003eThis compressor is mounted on a \u003cstrong\u003e120-gallon ASME air receiver tank\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eDoes this compressor include a refrigerated air dryer?\u003c\/h2\u003e\n\u003cp\u003eYes. The QRS 15D-150 TM includes a factory-installed refrigerated air dryer that helps remove moisture before compressed air enters the facility’s distribution system.\u003c\/p\u003e\n\u003ch2\u003eDoes the compressor include an aftercooler?\u003c\/h2\u003e\n\u003cp\u003eYes. The integrated aftercooler helps reduce compressed-air discharge temperature and condense moisture before the air reaches the refrigerated dryer and receiver tank.\u003c\/p\u003e\n\u003ch2\u003eIs additional filtration required?\u003c\/h2\u003e\n\u003cp\u003eAdditional filtration is recommended for most applications. General-purpose and coalescing filters help remove particulate contamination, condensed moisture, and oil aerosols that are not removed by the dryer alone.\u003c\/p\u003e\n\u003ch2\u003eIs this a single-phase compressor?\u003c\/h2\u003e\n\u003cp\u003eNo. This model requires \u003cstrong\u003ethree-phase electrical power\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat voltages can this compressor use?\u003c\/h2\u003e\n\u003cp\u003eThe compressor can be configured for \u003cstrong\u003e208, 230, or 460-volt three-phase power\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eCan this compressor operate continuously?\u003c\/h2\u003e\n\u003cp\u003eYes. The QRS rotary screw compressor is designed for continuous-duty applications when properly sized, installed, ventilated, and maintained.\u003c\/p\u003e\n\u003ch2\u003eHow loud is the Chicago Pneumatic QRS 15D-150 TM?\u003c\/h2\u003e\n\u003cp\u003eThe compressor has an approximate sound rating of \u003cstrong\u003e69 dBA\u003c\/strong\u003e, making it considerably quieter than many traditional open-frame reciprocating compressors.\u003c\/p\u003e\n\u003ch2\u003eWhat does the ES4000 controller monitor?\u003c\/h2\u003e\n\u003cp\u003eDepending on the installed controller revision, the ES4000 can monitor pressure, temperature, running hours, working hours, service requirements, alarms, and compressor operating status.\u003c\/p\u003e\n\u003ch2\u003eWhat is the advantage of a 150 PSI rotary screw compressor?\u003c\/h2\u003e\n\u003cp\u003eA 150 PSI compressor provides additional pressure capacity for demanding pneumatic equipment, tire-service applications, production machinery, and systems that experience pressure loss through piping and air-treatment equipment.\u003c\/p\u003e\n\u003ch2\u003eIs this compressor suitable for CNC equipment?\u003c\/h2\u003e\n\u003cp\u003eYes. Its continuous-duty performance, stable airflow, integrated refrigerated dryer, and 120-gallon receiver make it a strong option for properly sized CNC and manufacturing applications.\u003c\/p\u003e\n\u003ch2\u003eCan this compressor be used for paint applications?\u003c\/h2\u003e\n\u003cp\u003eYes, when properly sized. Paint applications normally require additional coalescing filtration and appropriate point-of-use air treatment.\u003c\/p\u003e\n\u003ch2\u003eDoes the refrigerated dryer remove oil?\u003c\/h2\u003e\n\u003cp\u003eNo. A refrigerated dryer primarily removes moisture by cooling the compressed air. Coalescing filtration is required to remove fine oil aerosols and other contaminants.\u003c\/p\u003e\n\u003ch2\u003eWhat pressure dew point does the dryer provide?\u003c\/h2\u003e\n\u003cp\u003eThe exact pressure dew point depends on the installed dryer model and operating conditions. Consult the dryer data plate or supplied documentation for its rated performance.\u003c\/p\u003e\n\u003ch2\u003eCan this compressor operate multiple air tools?\u003c\/h2\u003e\n\u003cp\u003eYes, provided the combined air consumption of the tools and equipment operating at the same time does not exceed the compressor’s rated output of 49.2 ACFM.\u003c\/p\u003e\n\u003ch2\u003eWhy choose a rotary screw compressor instead of a piston compressor?\u003c\/h2\u003e\n\u003cp\u003eA rotary screw compressor provides continuous-duty capability, smoother airflow, reduced vibration, quieter operation, and longer operating cycles compared with many traditional reciprocating compressors.\u003c\/p\u003e\n\u003ch2\u003eWhat is the difference between fixed-speed and variable-speed operation?\u003c\/h2\u003e\n\u003cp\u003eA fixed-speed compressor runs its motor at a constant speed and loads or unloads according to air demand. It is generally best suited for facilities with steady or predictable compressed-air usage.\u003c\/p\u003e\n\u003ch2\u003eHow do I determine whether 49.2 ACFM is enough?\u003c\/h2\u003e\n\u003cp\u003eAdd the CFM requirements of all tools and equipment that may operate simultaneously. Include additional capacity for compressed-air leaks, periods of peak demand, and future growth.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eWhy Buy from Compressed Air Advisors Online?\u003c\/h2\u003e\n\u003cp\u003eCompressed Air Advisors Online provides more than equipment in a box. Our team offers knowledgeable product-selection assistance, compressed-air system guidance, premium industrial manufacturers, and nationwide delivery.\u003c\/p\u003e\n\u003cp\u003eWe can help determine whether the Chicago Pneumatic QRS 15D-150 TM provides the correct airflow, pressure, electrical configuration, dryer capacity, storage capacity, and air quality for your application.\u003c\/p\u003e\n\u003cp\u003eWhen you need dependable compressed-air equipment supported by real-world application knowledge, Compressed Air Advisors Online is your compressed-air partner.\u003c\/p\u003e","brand":"Chicago Pneumatic","offers":[{"title":"Default Title","offer_id":12408841830470,"sku":"4152023183","price":16617.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0014\/6237\/0374\/products\/QRS_15_HPD_TM_2017_5813404f-4a0b-4f2f-8b94-d172fe96a047.jpg?v=1552849545","url":"https:\/\/www.compressedairadvisors.com\/products\/chicago-pneumatic-qrs-15d-150-tm-4152023183","provider":"Compressed Air Advisors Online, Inc. ","version":"1.0","type":"link"}