{"product_id":"emax-esp10v120v1-10-hp-silent-air-38-cfm-230v-1ph-120-gal","title":"EMAX ESP10V120V1 10 HP Silent Air | 38 CFM | 230V 1Ph | 120 Gal","description":"\u003cdiv style=\"font-family:inherit;\"\u003e\n\u003ch1 style=\"font-size:24px;line-height:1.3;margin:0 0 18px;font-weight:700;\"\u003eEMAX ESP10V120V1 10 HP Silent Air | 38 CFM | 230V 1Ph | 120 Gal\u003c\/h1\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003e\u003cstrong\u003e38 CFM at 100 PSI | 175 PSI Maximum | 230V Single-Phase | 120-Gallon Vertical Receiver\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eThe \u003cstrong\u003eEMAX ESP10V120V1 E450 Silent Air\u003c\/strong\u003e combines substantial 10 HP piston-compressor output with the features that matter in a working industrial shop: a \u003cstrong\u003epressure-lubricated two-stage cast-iron pump\u003c\/strong\u003e, patented Silent Air™ intake silencer, automatic tank drain and adjustable belt tensioner. Its 120-gallon vertical air receiver provides additional storage for intermittent demand peaks without the long footprint of a horizontal tank.\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eWith \u003cstrong\u003e38 CFM at 100 PSI\u003c\/strong\u003e, it is a strong candidate for automotive service, general manufacturing, fabrication and industrial maintenance where single-phase power is available. Compressor selection should also account for tool duty cycle, pressure loss and actual simultaneous consumption.\u003c\/p\u003e\n\u003chr style=\"border:0;border-top:1px solid #ddd;margin:24px 0;\"\u003e\n\u003ch2 style=\"font-size:20px;line-height:1.35;font-weight:700;margin:25px 0 13px;\"\u003eKey Features and Benefits\u003c\/h2\u003e\n\u003cul style=\"padding-left:24px;font-size:16px;line-height:1.6;margin:8px 0 24px;\"\u003e\n\u003cli style=\"margin:0 0 10px;\"\u003e\n\u003cstrong\u003e10 HP \/ 38 CFM at 100 PSI:\u003c\/strong\u003e High-volume air for demanding workstations and pneumatic tools.\u003c\/li\u003e\n\u003cli style=\"margin:0 0 10px;\"\u003e\n\u003cstrong\u003e175 PSI maximum operating pressure:\u003c\/strong\u003e Flexibility for properly regulated shop distribution.\u003c\/li\u003e\n\u003cli style=\"margin:0 0 10px;\"\u003e\n\u003cstrong\u003ePressure-lubricated cast-iron pump:\u003c\/strong\u003e Gear-driven oil delivery to critical moving components.\u003c\/li\u003e\n\u003cli style=\"margin:0 0 10px;\"\u003e\n\u003cstrong\u003eSilent Air™ technology:\u003c\/strong\u003e Patented intake noise suppression and high-capacity filtration.\u003c\/li\u003e\n\u003cli style=\"margin:0 0 10px;\"\u003e\n\u003cstrong\u003e120-gallon vertical receiver:\u003c\/strong\u003e Space-efficient air storage.\u003c\/li\u003e\n\u003cli style=\"margin:0 0 10px;\"\u003e\n\u003cstrong\u003eAutomatic timed tank drain:\u003c\/strong\u003e Helps remove collected moisture without relying exclusively on manual draining.\u003c\/li\u003e\n\u003cli style=\"margin:0 0 10px;\"\u003e\n\u003cstrong\u003eBelt tensioner:\u003c\/strong\u003e Simplifies tension and alignment adjustments.\u003c\/li\u003e\n\u003cli style=\"margin:0 0 10px;\"\u003e\n\u003cstrong\u003e230V single-phase:\u003c\/strong\u003e Substantial airflow without three-phase utility service.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr style=\"border:0;border-top:1px solid #ddd;margin:24px 0;\"\u003e\n\u003ch2 style=\"font-size:20px;line-height:1.35;font-weight:700;margin:25px 0 13px;\"\u003eWhat Makes the Pressure-Lubricated Pump Different?\u003c\/h2\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eThe pressure-lubricated pump employs a \u003cstrong\u003egear-driven oil pump\u003c\/strong\u003e at the rear of the crankshaft to direct oil through rifle-drilled passages in the crankshaft and connecting rods, reaching critical bearing and wrist-pin surfaces. A \u003cstrong\u003espin-on automotive-style oil filter\u003c\/strong\u003e removes contaminants, a liquid-filled gauge helps monitor oil pressure, and an adjustable regulator permits oil-pressure adjustment as specified by EMAX. An oil-pump bleeder valve supports priming after service. This targeted lubrication approach helps manage friction, wear and heat compared with relying solely on oil splash. Regular lubricant and filter maintenance remain essential.\u003c\/p\u003e\n\u003chr style=\"border:0;border-top:1px solid #ddd;margin:24px 0;\"\u003e\n\u003ch2 style=\"font-size:20px;line-height:1.35;font-weight:700;margin:25px 0 13px;\"\u003eCast-Iron Construction and Serviceability\u003c\/h2\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eEMAX describes cast-iron crankcases, cylinders, cylinder heads, crankshafts, connecting rods and high-pressure pistons in this pump family. Low-pressure pistons on two-stage pumps use aluminum to reduce reciprocating weight. The four-ring arrangement uses \u003cstrong\u003etwo oil-control rings and two compression rings\u003c\/strong\u003e to help maintain sealing and limit oil carryover. CNC-machined concentric disc valves can be removed for inspection, while replaceable bearing inserts and wrist pins support rebuildability. EMAX also describes precision-honed cylinder surfaces and non-oil-absorbent gaskets in this pump family.\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eFor its 7.5 and 10 HP pump family, EMAX describes a \u003cstrong\u003e20-inch cast-iron flywheel with nine cooling fins and two B-style belt grooves\u003c\/strong\u003e. The increased belt contact area supports reliable power transfer, while the cooling fins help move air across the pump. A pump riser is described as an available cooling feature, but inclusion on this exact SKU requires confirmation.\u003c\/p\u003e\n\u003chr style=\"border:0;border-top:1px solid #ddd;margin:24px 0;\"\u003e\n\u003ch2 style=\"font-size:20px;line-height:1.35;font-weight:700;margin:25px 0 13px;\"\u003eSilent Air™ Noise Suppression\u003c\/h2\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eThe patented Silent Air™ system channels incoming air through baffles and filtration to reduce intake noise while leaving the motor and pump accessible. EMAX advertises up to 50% quieter operation for its technology; actual performance varies by installation.\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eWatch the \u003ca href=\"https:\/\/www.youtube.com\/watch?v=_W_Pm-s1p2g\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eSilent Air demonstration\u003c\/a\u003e and \u003ca href=\"https:\/\/www.youtube.com\/watch?v=atakh7WsbDY\" target=\"_blank\" rel=\"noopener noreferrer\"\u003efiltration technology overview\u003c\/a\u003e.\u003c\/p\u003e\n\u003chr style=\"border:0;border-top:1px solid #ddd;margin:24px 0;\"\u003e\n\u003ch2 style=\"font-size:20px;line-height:1.35;font-weight:700;margin:25px 0 13px;\"\u003eAutomatic Drain, Belt Tensioner and Operating Controls\u003c\/h2\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eA timed automatic tank drain removes collected receiver condensate on a programmed schedule, reducing a commonly missed maintenance task. The belt tensioner improves accessibility for keeping the V-belt drive adjusted. EMAX lists continuous-run functionality for this E450 configuration, but the exact head-unloader arrangement and allowable operating duty must be confirmed. \u003cstrong\u003eContinuous-run features do not establish a 100% duty-cycle rating.\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr style=\"border:0;border-top:1px solid #ddd;margin:24px 0;\"\u003e\n\u003ch2 style=\"font-size:20px;line-height:1.35;margin:25px 0 13px;font-weight:700;\"\u003eAutomatic Drain and Dual-Bolt Belt Tensioner\u003c\/h2\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eThe EMAX dual-timer drain design allows the operator to adjust drain intervals from \u003cstrong\u003e1 to 45 minutes\u003c\/strong\u003e and set the valve-open duration to expel collected receiver condensate. EMAX also describes a discharge muffler on its premium drain assemblies. The dual-bolt belt tensioner permits more controlled alignment and belt adjustments without levering against the motor.\u003c\/p\u003e\n\u003chr style=\"border:0;border-top:1px solid #ddd;margin:24px 0;\"\u003e\n\u003ch2 style=\"font-size:20px;line-height:1.35;margin:25px 0 13px;font-weight:700;\"\u003eHead Unloaders for Higher-Duty Applications\u003c\/h2\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eEMAX offers head-unloader systems that hold the intake valve open when the compressor reaches a preset pressure, allowing the motor to continue turning without compressing air. This can reduce repetitive loaded starts and help move cooling air through the cylinders. \u003cstrong\u003eHead-unloader installation and continuous-running suitability on this particular ESP10V120V1 must be confirmed\u003c\/strong\u003e; this feature does not alone establish a 100% duty-cycle rating.\u003c\/p\u003e\n\u003chr style=\"border:0;border-top:1px solid #ddd;margin:24px 0;\"\u003e\n\u003ch2 style=\"font-size:20px;line-height:1.35;margin:25px 0 13px;font-weight:700;\"\u003eV-Belt Drive: Why the Design Matters\u003c\/h2\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eThe dual B-groove belt arrangement provides more contact area for power transfer than a narrow single-belt drive. Sharing load across two belts can reduce belt tension requirements, help minimize strain on motor and compressor bearings, and limit vibration when properly aligned and maintained. These advantages support a durable drive system with practical service access.\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eThis 10 HP model also includes a \u003cstrong\u003epump riser\u003c\/strong\u003e for improved airflow beneath the crankcase, a \u003cstrong\u003ebelt tensioner\u003c\/strong\u003e for easier adjustment, and a \u003cstrong\u003emagnetic starter\u003c\/strong\u003e. EMAX specifies no radiator aftercooler for this configuration.\u003c\/p\u003e\n\u003chr style=\"border:0;border-top:1px solid #ddd;margin:24px 0;\"\u003e\n\u003ch2 style=\"font-size:20px;line-height:1.35;margin:25px 0 13px;font-weight:700;\"\u003e80-Gallon vs. 120-Gallon: What Changes?\u003c\/h2\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eThe E450 80-gallon and 120-gallon 10 HP versions both produce \u003cstrong\u003e38 CFM at 100 PSI\u003c\/strong\u003e. The 120-gallon receiver provides extra stored air for intermittent peaks, but does not increase compressor output or make an undersized compressor suitable for sustained high air consumption.\u003c\/p\u003e\n\u003chr style=\"border:0;border-top:1px solid #ddd;margin:24px 0;\"\u003e\n\u003ch2 style=\"font-size:20px;line-height:1.35;margin:25px 0 13px;font-weight:700;\"\u003eVerified Pump, Motor, and Electrical Specifications\u003c\/h2\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eThis model combines the \u003cstrong\u003eAPP4V1043TP pressure-lubricated pump at 730 RPM\u003c\/strong\u003e with an \u003cstrong\u003eODP 1,740 RPM single-phase motor\u003c\/strong\u003e. EMAX confirms a factory magnetic starter, pump riser, belt tensioner, and automatic tank drain. The manufacturer lists \u003cstrong\u003e52.90 A including the 1.15 service factor\u003c\/strong\u003e, \u003cstrong\u003e270 A starting\/locked rotor current\u003c\/strong\u003e, and a \u003cstrong\u003e60 A recommended breaker\u003c\/strong\u003e. Electrical installation must be evaluated by a qualified electrician.\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eThe compressor measures \u003cstrong\u003e44 × 31 × 80 inches\u003c\/strong\u003e and weighs \u003cstrong\u003e967 lb uncrated\u003c\/strong\u003e. EMAX lists a crated weight of \u003cstrong\u003e1,116 lb\u003c\/strong\u003e and crate dimensions of \u003cstrong\u003e48 × 46 × 87 inches\u003c\/strong\u003e. Verify receiving and lift equipment capacity before delivery.\u003c\/p\u003e\n\u003chr style=\"border:0;border-top:1px solid #ddd;margin:24px 0;\"\u003e\n\u003ch2 style=\"font-size:20px;line-height:1.35;font-weight:700;margin:25px 0 13px;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0 24px;font-size:16px;\"\u003e\u003ctbody\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;vertical-align:top;padding:10px 12px;width:42%;\"\u003eModel \/ SKU\u003c\/th\u003e\n\u003ctd style=\"padding:10px 12px;\"\u003eESP10V120V1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;background-color:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;vertical-align:top;padding:10px 12px;width:42%;\"\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd style=\"padding:10px 12px;\"\u003eE01PSXXP10V120VXXXX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;vertical-align:top;padding:10px 12px;width:42%;\"\u003eUPC\u003c\/th\u003e\n\u003ctd style=\"padding:10px 12px;\"\u003e815002014739\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;background-color:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;vertical-align:top;padding:10px 12px;width:42%;\"\u003ePower\u003c\/th\u003e\n\u003ctd style=\"padding:10px 12px;\"\u003e10 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;vertical-align:top;padding:10px 12px;width:42%;\"\u003eAir Delivery\u003c\/th\u003e\n\u003ctd style=\"padding:10px 12px;\"\u003e38 CFM at 100 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;background-color:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;vertical-align:top;padding:10px 12px;width:42%;\"\u003eMaximum Working Pressure\u003c\/th\u003e\n\u003ctd style=\"padding:10px 12px;\"\u003e175 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;vertical-align:top;padding:10px 12px;width:42%;\"\u003eVoltage \/ Phase\u003c\/th\u003e\n\u003ctd style=\"padding:10px 12px;\"\u003e230V \/ 1 Phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;background-color:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;vertical-align:top;padding:10px 12px;width:42%;\"\u003eReceiver\u003c\/th\u003e\n\u003ctd style=\"padding:10px 12px;\"\u003e120 Gallon Vertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;vertical-align:top;padding:10px 12px;width:42%;\"\u003ePump Model\u003c\/th\u003e\n\u003ctd style=\"padding:10px 12px;\"\u003eAPP4V1043TP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;background-color:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;vertical-align:top;padding:10px 12px;width:42%;\"\u003ePump Type\u003c\/th\u003e\n\u003ctd style=\"padding:10px 12px;\"\u003eTwo-stage pressure-lubricated piston\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;vertical-align:top;padding:10px 12px;width:42%;\"\u003ePump Speed\u003c\/th\u003e\n\u003ctd style=\"padding:10px 12px;\"\u003e730 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;background-color:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;vertical-align:top;padding:10px 12px;width:42%;\"\u003eMotor\u003c\/th\u003e\n\u003ctd style=\"padding:10px 12px;\"\u003eODP, 1,740 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;vertical-align:top;padding:10px 12px;width:42%;\"\u003ePeak Starting Amps\u003c\/th\u003e\n\u003ctd style=\"padding:10px 12px;\"\u003e270 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;background-color:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;vertical-align:top;padding:10px 12px;width:42%;\"\u003eLocked Rotor Amps\u003c\/th\u003e\n\u003ctd style=\"padding:10px 12px;\"\u003e270 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;vertical-align:top;padding:10px 12px;width:42%;\"\u003eFull Load Amps + 1.15 SF\u003c\/th\u003e\n\u003ctd style=\"padding:10px 12px;\"\u003e52.90 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;background-color:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;vertical-align:top;padding:10px 12px;width:42%;\"\u003eRecommended Breaker\u003c\/th\u003e\n\u003ctd style=\"padding:10px 12px;\"\u003e60 A (confirm with qualified electrician)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;vertical-align:top;padding:10px 12px;width:42%;\"\u003eSilent Air\u003c\/th\u003e\n\u003ctd style=\"padding:10px 12px;\"\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;background-color:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;vertical-align:top;padding:10px 12px;width:42%;\"\u003eAutomatic Tank Drain\u003c\/th\u003e\n\u003ctd style=\"padding:10px 12px;\"\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;vertical-align:top;padding:10px 12px;width:42%;\"\u003eMagnetic Starter\u003c\/th\u003e\n\u003ctd style=\"padding:10px 12px;\"\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;background-color:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;vertical-align:top;padding:10px 12px;width:42%;\"\u003eBelt Tensioner\u003c\/th\u003e\n\u003ctd style=\"padding:10px 12px;\"\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;vertical-align:top;padding:10px 12px;width:42%;\"\u003ePump Riser\u003c\/th\u003e\n\u003ctd style=\"padding:10px 12px;\"\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;background-color:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;vertical-align:top;padding:10px 12px;width:42%;\"\u003eRadiator Aftercooler\u003c\/th\u003e\n\u003ctd style=\"padding:10px 12px;\"\u003eNot included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;vertical-align:top;padding:10px 12px;width:42%;\"\u003eSmart Air\u003c\/th\u003e\n\u003ctd style=\"padding:10px 12px;\"\u003eNot included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;background-color:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;vertical-align:top;padding:10px 12px;width:42%;\"\u003eOutlet Size\u003c\/th\u003e\n\u003ctd style=\"padding:10px 12px;\"\u003e1 inch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;vertical-align:top;padding:10px 12px;width:42%;\"\u003eBelt Count\u003c\/th\u003e\n\u003ctd style=\"padding:10px 12px;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;background-color:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;vertical-align:top;padding:10px 12px;width:42%;\"\u003eOil Capacity\u003c\/th\u003e\n\u003ctd style=\"padding:10px 12px;\"\u003e2 quarts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;vertical-align:top;padding:10px 12px;width:42%;\"\u003eUncrated Dimensions\u003c\/th\u003e\n\u003ctd style=\"padding:10px 12px;\"\u003e44 × 31 × 80 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;background-color:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;vertical-align:top;padding:10px 12px;width:42%;\"\u003eCrated Dimensions\u003c\/th\u003e\n\u003ctd style=\"padding:10px 12px;\"\u003e48 × 46 × 87 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;vertical-align:top;padding:10px 12px;width:42%;\"\u003eUncrated Weight\u003c\/th\u003e\n\u003ctd style=\"padding:10px 12px;\"\u003e967 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;background-color:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;vertical-align:top;padding:10px 12px;width:42%;\"\u003eCrated Weight\u003c\/th\u003e\n\u003ctd style=\"padding:10px 12px;\"\u003e1,116 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;vertical-align:top;padding:10px 12px;width:42%;\"\u003eEstimated Pump Life\u003c\/th\u003e\n\u003ctd style=\"padding:10px 12px;\"\u003e70,000 hours (manufacturer estimate; maintenance required)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;background-color:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;vertical-align:top;padding:10px 12px;width:42%;\"\u003eCertifications\u003c\/th\u003e\n\u003ctd style=\"padding:10px 12px;\"\u003eETL, ASME, CRN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;vertical-align:top;padding:10px 12px;width:42%;\"\u003eService Kit\u003c\/th\u003e\n\u003ctd style=\"padding:10px 12px;\"\u003eEFKIT008AWBS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003chr style=\"border:0;border-top:1px solid #ddd;margin:24px 0;\"\u003e\n\u003ch2 style=\"font-size:20px;line-height:1.35;font-weight:700;margin:25px 0 13px;\"\u003eBefore You Order\u003c\/h2\u003e\n\u003cul style=\"padding-left:24px;font-size:16px;line-height:1.6;margin:8px 0 24px;\"\u003e\n\u003cli style=\"margin:0 0 10px;\"\u003eAdd the CFM demand of tools operating simultaneously, not just the largest tool.\u003c\/li\u003e\n\u003cli style=\"margin:0 0 10px;\"\u003eCheck required pressure at the workstation after piping and filter losses.\u003c\/li\u003e\n\u003cli style=\"margin:0 0 10px;\"\u003eVerify 230V single-phase electrical supply, circuit protection and starting requirements.\u003c\/li\u003e\n\u003cli style=\"margin:0 0 10px;\"\u003ePlan ventilation and service clearance around the compressor.\u003c\/li\u003e\n\u003cli style=\"margin:0 0 10px;\"\u003eFor extended air demand, confirm duty cycle and discuss whether a rotary screw compressor would be a better fit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr style=\"border:0;border-top:1px solid #ddd;margin:24px 0;\"\u003e\n\u003ch2 style=\"font-size:20px;line-height:1.35;font-weight:700;margin:25px 0 13px;\"\u003eComplete Your Compressed-Air System\u003c\/h2\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eConsider a correctly sized \u003ca href=\"https:\/\/www.compressedairadvisors.com\/collections\/air-dryers\"\u003eair dryer\u003c\/a\u003e, \u003ca href=\"https:\/\/www.compressedairadvisors.com\/collections\/in-line-air-filters-and-water-separators\"\u003ecompressed-air filtration\u003c\/a\u003e and \u003ca href=\"https:\/\/www.compressedairadvisors.com\/collections\/maintenance\"\u003emaintenance supplies\u003c\/a\u003e. These can be selected around your desired air quality, environment and work schedule.\u003c\/p\u003e\n\u003chr style=\"border:0;border-top:1px solid #ddd;margin:24px 0;\"\u003e\n\u003ch2 style=\"font-size:20px;line-height:1.35;font-weight:700;margin:25px 0 13px;\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003e\u003cstrong\u003eIs the ESP10V120V1 a single-phase compressor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eYes. The ESP10V120V1 is configured for 230V single-phase electrical service. Confirm wiring, starting current and protective devices with a qualified electrician.\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003e\u003cstrong\u003eHow much air does this 10 HP compressor produce?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eEMAX rates it at 38 CFM at 100 PSI, with a maximum operating pressure of 175 PSI.\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003e\u003cstrong\u003eDoes it include Silent Air™?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eYes. The patented EMAX intake silencer uses baffle plates and filter media to reduce compressor intake noise.\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003e\u003cstrong\u003eHow does it differ from the 10 HP E350?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eBoth are listed at 38 CFM at 100 PSI. The E450 adds a belt tensioner, automatic tank drain and manufacturer-listed continuous-run controls.\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003e\u003cstrong\u003eDoes it have a pressure-lubricated pump?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eYes. Its pressure-lubricated cast-iron pump uses a dedicated oil-delivery system, unlike splash-lubricated entry-level models.\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003e\u003cstrong\u003eDoes continuous-run mean 100% duty cycle?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eNo. The exact head-unloader arrangement and appropriate duty cycle should be confirmed for your use before selecting the compressor for sustained workloads.\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003e\u003cstrong\u003eIs an air dryer included?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eNo. Dryers and downstream filters are selected separately to suit the application.\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003e\u003cstrong\u003eWhat maintenance is required?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eMaintain oil level and changes, oil and intake filters, belt tension and operation of the automatic tank drain according to EMAX service instructions.\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eFor application-specific compressor sizing, contact Compressed Air Advisors Online at \u003cstrong\u003e877-247-2381\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"Is the ESP10V120V1 a single-phase compressor?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. The ESP10V120V1 is configured for 230V single-phase electrical service. Confirm wiring, starting current and protective devices with a qualified electrician.\"}},{\"@type\":\"Question\",\"name\":\"How much air does this 10 HP compressor produce?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"EMAX rates it at 38 CFM at 100 PSI, with a maximum operating pressure of 175 PSI.\"}},{\"@type\":\"Question\",\"name\":\"Does it include Silent Air™?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. The patented EMAX intake silencer uses baffle plates and filter media to reduce compressor intake noise.\"}},{\"@type\":\"Question\",\"name\":\"How does it differ from the 10 HP E350?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Both are listed at 38 CFM at 100 PSI. The E450 adds a belt tensioner, automatic tank drain and manufacturer-listed continuous-run controls.\"}},{\"@type\":\"Question\",\"name\":\"Does it have a pressure-lubricated pump?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. Its pressure-lubricated cast-iron pump uses a dedicated oil-delivery system, unlike splash-lubricated entry-level models.\"}},{\"@type\":\"Question\",\"name\":\"Does continuous-run mean 100% duty cycle?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"No. The exact head-unloader arrangement and appropriate duty cycle should be confirmed for your use before selecting the compressor for sustained workloads.\"}},{\"@type\":\"Question\",\"name\":\"Is an air dryer included?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"No. Dryers and downstream filters are selected separately to suit the application.\"}},{\"@type\":\"Question\",\"name\":\"What maintenance is required?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Maintain oil level and changes, oil and intake filters, belt tension and operation of the automatic tank drain according to EMAX service instructions.\"}}]}\u003c\/script\u003e\n\u003c\/div\u003e","brand":"EMAX","offers":[{"title":"Default Title","offer_id":50841757450310,"sku":"ESP10V120V1","price":6697.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0014\/6237\/0374\/files\/ESP10V120V1-1_LeadTime-scaled.jpg?v=1793206454","url":"https:\/\/www.compressedairadvisors.com\/products\/emax-esp10v120v1-10-hp-silent-air-38-cfm-230v-1ph-120-gal","provider":"Compressed Air Advisors Online, Inc. ","version":"1.0","type":"link"}