{"product_id":"emax-esp15v120y3-208-15-hp-silent-air-57-cfm-208-230v-3ph","title":"EMAX ESP15V120Y3-208 15 HP Silent Air | 58 CFM | 208\/230V 3Ph","description":"\u003cdiv style=\"font-family:inherit\"\u003e\n\u003ch1 style=\"font-size:24px;font-weight:700;line-height:1.3;margin:0 0 18px;\"\u003eEMAX ESP15V120Y3-208 15 HP Silent Air | 58 CFM | 208\/230V 3Ph\u003c\/h1\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003e\u003cstrong\u003e15 HP | 58 CFM at 100 PSI | 175 PSI Maximum | 208\/230V Three-Phase | 120-Gallon Vertical Receiver\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eThe \u003cstrong\u003eEMAX ESP15V120Y3-208 E450 Silent Air\u003c\/strong\u003e is an industrial two-stage reciprocating air compressor delivering \u003cstrong\u003e58 CFM at 100 PSI\u003c\/strong\u003e. Its cast-iron pressure-lubricated pump, patented Silent Air intake and 120-gallon vertical receiver suit professional shops and industrial facilities with three-phase power.\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eBefore selecting a compressor, compare its rated 58 CFM with all tools and processes that will operate simultaneously. The 120-gallon receiver helps cushion intermittent demand, but does not increase sustained pump capacity.\u003c\/p\u003e\n\u003chr style=\"border:0;border-top:1px solid #ddd;margin:24px 0;\"\u003e\n\u003ch2 style=\"font-size:20px;font-weight:700;margin:25px 0 13px;\"\u003eKey Features and Benefits\u003c\/h2\u003e\n\u003cul style=\"font-size:16px;line-height:1.65;padding-left:24px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003e15 HP, 58 CFM:\u003c\/strong\u003e High airflow for correctly sized shop and production equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure-lubricated cast-iron pump:\u003c\/strong\u003e Gear-driven oil supply to crankshaft and connecting-rod bearings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSilent Air™:\u003c\/strong\u003e Patented intake baffles and filtration reduce intake noise without a full enclosure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e120-gallon vertical receiver:\u003c\/strong\u003e Air storage with reduced floor length compared with horizontal tanks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic tank drain:\u003c\/strong\u003e Timed discharge of receiver condensate.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBelt tensioner:\u003c\/strong\u003e Facilitates accurate, repeatable belt adjustment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e208\/230V three-phase:\u003c\/strong\u003e Designed for facilities with compatible industrial electrical service.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr style=\"border:0;border-top:1px solid #ddd;margin:24px 0;\"\u003e\n\u003ch2 style=\"font-size:20px;font-weight:700;margin:25px 0 13px;\"\u003ePressure-Lubricated Pump Construction\u003c\/h2\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eEMAX's pressure-lubricated pump family uses a gear oil pump and drilled crankshaft and connecting-rod passages to deliver lubricant to critical bearings. A spin-on oil filter helps remove contaminants and a liquid-filled oil pressure gauge permits operating checks. Cast-iron major pump components, four-ring pistons, concentric disc valves and serviceable bearing assemblies support durability and maintenance access.\u003c\/p\u003e\n\u003chr style=\"border:0;border-top:1px solid #ddd;margin:24px 0;\"\u003e\n\u003ch2 style=\"font-size:20px;font-weight:700;margin:25px 0 13px;\"\u003eSilent Air™, Cooling and Service\u003c\/h2\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eSilent Air™ uses noise-reducing baffles and high-capacity intake filter media. EMAX advertises up to 50% quieter operation, depending on the environment and application. The manufacturer's 15 HP pump family uses a heavy-duty cast-iron flywheel and cooling fins; EMAX specifies two drive belts on this particular configuration. Follow the specific model's belt and maintenance instructions.\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eThe adjustable automatic receiver drain helps expel collected moisture. Review the desired operating duty cycle and verify continuous-run\/head-unloader equipment with EMAX rather than assuming the unit can operate continuously without limitations.\u003c\/p\u003e\n\u003chr style=\"border:0;border-top:1px solid #ddd;margin:24px 0;\"\u003e\n\u003ch2 style=\"font-size:20px;font-weight:700;margin:25px 0 13px;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003e\u003cstrong\u003eModel-specific manufacturer data:\u003c\/strong\u003e This unit has an APP3Y2062TP pressure-lubricated two-stage pump operating at 815 RPM, with a 1,740 RPM TEFC motor, factory magnetic starter, pump riser and two drive belts. EMAX specifies 41.90 A including the 1.15 service factor, 237 A starting\/locked-rotor current, and a 70 A recommended breaker. Have a qualified electrician verify branch circuit and protection requirements.\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eThe pump oil capacity is 3 quarts and the listed service kit is EFKIT009AWB. Equipment weight is 1,138 lb uncrated and 1,287 lb crated. Shipping arrangements should accommodate these weights.\u003c\/p\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;font-size:16px;\"\u003e\u003ctbody\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px;width:42%;\"\u003eModel \/ SKU\u003c\/th\u003e\n\u003ctd style=\"padding:10px;\"\u003eESP15V120Y3-208\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;background:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px;width:42%;\"\u003eManufacturer MPN\u003c\/th\u003e\n\u003ctd style=\"padding:10px;\"\u003eE01PSXXP15V120Y208X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px;width:42%;\"\u003eUPC\u003c\/th\u003e\n\u003ctd style=\"padding:10px;\"\u003e810070051389\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;background:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px;width:42%;\"\u003eHorsepower\u003c\/th\u003e\n\u003ctd style=\"padding:10px;\"\u003e15 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px;width:42%;\"\u003eAir Delivery\u003c\/th\u003e\n\u003ctd style=\"padding:10px;\"\u003e58 CFM (current manufacturer sheet; pricing matrix lists 57 CFM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;background:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px;width:42%;\"\u003eMaximum Pressure\u003c\/th\u003e\n\u003ctd style=\"padding:10px;\"\u003e175 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px;width:42%;\"\u003ePower Supply\u003c\/th\u003e\n\u003ctd style=\"padding:10px;\"\u003e208\/230V three-phase (manufacturer nominal 230V ±10%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;background:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px;width:42%;\"\u003eTank\u003c\/th\u003e\n\u003ctd style=\"padding:10px;\"\u003e120-gallon vertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px;width:42%;\"\u003eMotor\u003c\/th\u003e\n\u003ctd style=\"padding:10px;\"\u003eTEFC, 1,740 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;background:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px;width:42%;\"\u003eFull Load Amps + 1.15 Service Factor\u003c\/th\u003e\n\u003ctd style=\"padding:10px;\"\u003e41.90 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px;width:42%;\"\u003ePeak Starting \/ Locked Rotor Amps\u003c\/th\u003e\n\u003ctd style=\"padding:10px;\"\u003e237 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;background:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px;width:42%;\"\u003eRecommended Breaker\u003c\/th\u003e\n\u003ctd style=\"padding:10px;\"\u003e70 A (verify with electrician)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px;width:42%;\"\u003ePump Model\u003c\/th\u003e\n\u003ctd style=\"padding:10px;\"\u003eAPP3Y2062TP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;background:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px;width:42%;\"\u003ePump Speed\u003c\/th\u003e\n\u003ctd style=\"padding:10px;\"\u003e815 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px;width:42%;\"\u003ePump Type\u003c\/th\u003e\n\u003ctd style=\"padding:10px;\"\u003eTwo-stage, pressure-lubricated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;background:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px;width:42%;\"\u003eOutlet\u003c\/th\u003e\n\u003ctd style=\"padding:10px;\"\u003e1 inch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px;width:42%;\"\u003eDrive Belts\u003c\/th\u003e\n\u003ctd style=\"padding:10px;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;background:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px;width:42%;\"\u003eMagnetic Starter\u003c\/th\u003e\n\u003ctd style=\"padding:10px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px;width:42%;\"\u003ePump Riser\u003c\/th\u003e\n\u003ctd style=\"padding:10px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;background:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px;width:42%;\"\u003eBelt Tensioner\u003c\/th\u003e\n\u003ctd style=\"padding:10px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px;width:42%;\"\u003eAutomatic Tank Drain\u003c\/th\u003e\n\u003ctd style=\"padding:10px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;background:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px;width:42%;\"\u003eSilent Air\u003c\/th\u003e\n\u003ctd style=\"padding:10px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px;width:42%;\"\u003eSmart Air\u003c\/th\u003e\n\u003ctd style=\"padding:10px;\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;background:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px;width:42%;\"\u003eRadiator Aftercooler\u003c\/th\u003e\n\u003ctd style=\"padding:10px;\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px;width:42%;\"\u003eOil Capacity\u003c\/th\u003e\n\u003ctd style=\"padding:10px;\"\u003e3 quarts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;background:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px;width:42%;\"\u003eUncrated Weight\u003c\/th\u003e\n\u003ctd style=\"padding:10px;\"\u003e1,138 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px;width:42%;\"\u003eCrated Weight\u003c\/th\u003e\n\u003ctd style=\"padding:10px;\"\u003e1,287 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;background:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px;width:42%;\"\u003eCrated Dimensions\u003c\/th\u003e\n\u003ctd style=\"padding:10px;\"\u003eLength 48 in, width 46 in; height not supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px;width:42%;\"\u003eEstimated Pump Life\u003c\/th\u003e\n\u003ctd style=\"padding:10px;\"\u003e70,000 hours (manufacturer estimate)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;background:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px;width:42%;\"\u003eCertifications\u003c\/th\u003e\n\u003ctd style=\"padding:10px;\"\u003eETL, ASME, CRN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px;width:42%;\"\u003eService Kit\u003c\/th\u003e\n\u003ctd style=\"padding:10px;\"\u003eEFKIT009AWB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003chr style=\"border:0;border-top:1px solid #ddd;margin:24px 0;\"\u003e\n\u003ch2 style=\"font-size:20px;font-weight:700;margin:25px 0 13px;\"\u003eSizing and Installation Recommendations\u003c\/h2\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eHave a qualified electrician confirm the site's three-phase service, motor starting current and branch protection. Maintain clearances around the drive, pump, motor and air intake. Confirm exact dimensions and shipping weight before arranging installation and unloading.\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003ePair with a suitably sized \u003ca href=\"https:\/\/www.compressedairadvisors.com\/collections\/air-dryers\"\u003eair dryer\u003c\/a\u003e and \u003ca href=\"https:\/\/www.compressedairadvisors.com\/collections\/in-line-air-filters-and-water-separators\"\u003ecompressed-air filtration\u003c\/a\u003e where the application requires clean, dry air. See \u003ca href=\"https:\/\/www.compressedairadvisors.com\/collections\/maintenance\"\u003ecompressor maintenance supplies\u003c\/a\u003e for periodic service.\u003c\/p\u003e\n\u003chr style=\"border:0;border-top:1px solid #ddd;margin:24px 0;\"\u003e\n\u003ch2 style=\"font-size:20px;font-weight:700;margin:25px 0 13px;\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003e\u003cstrong\u003eHow much air does this compressor deliver?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eEMAX lists 58 CFM at 100 PSI with a maximum working pressure of 175 PSI.\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003e\u003cstrong\u003eIs this 15 HP compressor single-phase?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eNo. This ESP15V120Y3-208 is the 208\/230V three-phase configuration.\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003e\u003cstrong\u003eDoes the 120-gallon tank provide 58 CFM continuously?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eThe pump is rated at 58 CFM at 100 PSI. The receiver stores air for intermittent peaks but does not increase the pump's continuous output.\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003e\u003cstrong\u003eWhat does the pressure-lubricated pump do differently?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eA gear-driven oil pump distributes filtered lubricant through drilled internal passages to critical wear components.\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003e\u003cstrong\u003eIs the compressor quiet?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eSilent Air technology reduces intake sound using patented baffles and high-capacity filtration; EMAX advertises up to 50% quieter operation under applicable conditions.\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003e\u003cstrong\u003eDoes the unit drain condensed water automatically?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eYes, the E450 Silent Air series lists an automatic tank drain, with adjustable discharge timing.\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003e\u003cstrong\u003eDoes it include a refrigerated air dryer?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eNo. A properly sized dryer and filtration package can be purchased separately for moisture-sensitive applications.\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003e\u003cstrong\u003eCan I use this compressor for extended high-demand work?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eConfirm duty-cycle suitability and the exact continuous-run\/head-unloader configuration with EMAX. Do not assume an unrestricted 100% duty rating.\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003e\u003cstrong\u003eWhat electrical breaker is required?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eThe exact current and protection requirements should be confirmed from this model's data sheet and by a qualified electrician before installation.\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eQuestions about sizing? Call \u003cstrong\u003e877-247-2381\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"How much air does this compressor deliver?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"EMAX lists 58 CFM at 100 PSI with a maximum working pressure of 175 PSI.\"}},{\"@type\":\"Question\",\"name\":\"Is this 15 HP compressor single-phase?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"No. This ESP15V120Y3-208 is the 208\/230V three-phase configuration.\"}},{\"@type\":\"Question\",\"name\":\"Does the 120-gallon tank provide 58 CFM continuously?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"The pump is rated at 58 CFM at 100 PSI. The receiver stores air for intermittent peaks but does not increase the pump's continuous output.\"}},{\"@type\":\"Question\",\"name\":\"What does the pressure-lubricated pump do differently?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"A gear-driven oil pump distributes filtered lubricant through drilled internal passages to critical wear components.\"}},{\"@type\":\"Question\",\"name\":\"Is the compressor quiet?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Silent Air technology reduces intake sound using patented baffles and high-capacity filtration; EMAX advertises up to 50% quieter operation under applicable conditions.\"}},{\"@type\":\"Question\",\"name\":\"Does the unit drain condensed water automatically?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes, the E450 Silent Air series lists an automatic tank drain, with adjustable discharge timing.\"}},{\"@type\":\"Question\",\"name\":\"Does it include a refrigerated air dryer?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"No. A properly sized dryer and filtration package can be purchased separately for moisture-sensitive applications.\"}},{\"@type\":\"Question\",\"name\":\"Can I use this compressor for extended high-demand work?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Confirm duty-cycle suitability and the exact continuous-run\/head-unloader configuration with EMAX. Do not assume an unrestricted 100% duty rating.\"}},{\"@type\":\"Question\",\"name\":\"What electrical breaker is required?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"The exact current and protection requirements should be confirmed from this model's data sheet and by a qualified electrician before installation.\"}}]}\u003c\/script\u003e\n\u003c\/div\u003e","brand":"EMAX","offers":[{"title":"Default Title","offer_id":50842550304838,"sku":"ESP15V120Y3-208","price":8702.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0014\/6237\/0374\/files\/ESP15V120Y3-208-1-3-scaled.jpg?v=1793220965","url":"https:\/\/www.compressedairadvisors.com\/products\/emax-esp15v120y3-208-15-hp-silent-air-57-cfm-208-230v-3ph","provider":"Compressed Air Advisors Online, Inc. ","version":"1.0","type":"link"}