{"product_id":"emax-esp15v120y3-460-15-hp-silent-air-58-cfm-460v-3ph","title":"EMAX ESP15V120Y3-460 15 HP Silent Air | 58 CFM | 460V 3Ph","description":"\u003cdiv style=\"font-family:inherit\"\u003e\n\u003ch1 style=\"font-size:24px;font-weight:700;line-height:1.3;margin:0 0 18px;\"\u003eEMAX ESP15V120Y3-460 15 HP Silent Air | 58 CFM | 460V 3Ph\u003c\/h1\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003e\u003cstrong\u003e15 HP | 58 CFM per Model Specification | 175 PSI Maximum | 460V Three-Phase | 120-Gallon Vertical Receiver\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eThe \u003cstrong\u003eEMAX ESP15V120Y3-460 E450 Silent Air\u003c\/strong\u003e is a heavy-duty, two-stage reciprocating compressor for manufacturing, automotive service and industrial shops with 460V three-phase service. It combines a cast-iron pressure-lubricated pump with patented Silent Air™ intake noise suppression, an automatic tank drain, and a vertical 120-gallon air receiver.\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eFor equipment sizing, compare the required tool and process CFM at operating pressure against the published rating. EMAX's current model sheet states \u003cstrong\u003e58 CFM\u003c\/strong\u003e, while its September 2026 pricing file states 57 CFM. The difference is being verified before publication.\u003c\/p\u003e\n\u003chr style=\"border:0;border-top:1px solid #ddd;margin:24px 0;\"\u003e\n\u003ch2 style=\"font-size:20px;font-weight:700;margin:25px 0 13px;\"\u003eKey Features and Benefits\u003c\/h2\u003e\n\u003cul style=\"font-size:16px;line-height:1.6;padding-left:24px;margin:12px 0 22px;\"\u003e\n\u003cli style=\"margin-bottom:8px;\"\u003e\n\u003cstrong\u003e15 HP two-stage industrial piston compressor:\u003c\/strong\u003e High-capacity shop air for correctly sized pneumatic systems.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:8px;\"\u003e\n\u003cstrong\u003ePressure-lubricated APP3Y2062TP pump:\u003c\/strong\u003e Gear-driven oil pump and filtered lubrication to critical components.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:8px;\"\u003e\n\u003cstrong\u003eSilent Air™ intake:\u003c\/strong\u003e Patented sound-suppression baffles and high-capacity filtration media.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:8px;\"\u003e\n\u003cstrong\u003e120-gallon vertical receiver:\u003c\/strong\u003e Air storage to buffer intermittent demand without increasing pump output.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:8px;\"\u003e\n\u003cstrong\u003eTEFC three-phase motor:\u003c\/strong\u003e 1,740 RPM industrial motor designed for 460V service.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:8px;\"\u003e\n\u003cstrong\u003eAutomatic timed drain:\u003c\/strong\u003e Helps expel condensed water from the receiver.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:8px;\"\u003e\n\u003cstrong\u003eMagnetic starter, pump riser and belt tensioner:\u003c\/strong\u003e Manufacturer-confirmed equipment for starting control, cooling airflow and drive service.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr style=\"border:0;border-top:1px solid #ddd;margin:24px 0;\"\u003e\n\u003ch2 style=\"font-size:20px;font-weight:700;margin:25px 0 13px;\"\u003ePressure-Lubricated Cast-Iron Pump\u003c\/h2\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eA gear-driven oil pump sends lubricant through rifle-drilled crankshaft and connecting-rod passages to internal bearing surfaces. EMAX's pump family incorporates an automotive-style spin-on filter and an oil pressure gauge for service monitoring. Cast-iron crankcase, cylinders, heads, crankshaft, rods and high-pressure pistons are designed for demanding operation; the low-pressure two-stage piston is aluminum to limit reciprocating mass.\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eFour-ring pistons help control blow-by and oil carryover. Replaceable bearing components and serviceable concentric disc valves support long-term maintenance. The \u003cstrong\u003eAPP3Y2062TP pump runs at 815 RPM\u003c\/strong\u003e and requires \u003cstrong\u003e3 quarts of oil\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr style=\"border:0;border-top:1px solid #ddd;margin:24px 0;\"\u003e\n\u003ch2 style=\"font-size:20px;font-weight:700;margin:25px 0 13px;\"\u003eSilent Air™, Cooling and Drive Design\u003c\/h2\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eThe patented Silent Air intake uses acoustic baffles and high-capacity filtration to reduce intake sound, with EMAX advertising up to 50% quieter operation under qualifying conditions. The factory pump riser improves cooling airflow beneath the pump crankcase. The model-specific sheet confirms two drive belts and a belt tensioner for easier adjustment.\u003c\/p\u003e\n\u003chr style=\"border:0;border-top:1px solid #ddd;margin:24px 0;\"\u003e\n\u003ch2 style=\"font-size:20px;font-weight:700;margin:25px 0 13px;\"\u003eInstallation and Electrical Considerations\u003c\/h2\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eThis model is supplied for \u003cstrong\u003e460V three-phase\u003c\/strong\u003e power. EMAX lists \u003cstrong\u003e20.90A\u003c\/strong\u003e full-load current including the 1.15 service factor, \u003cstrong\u003e118A\u003c\/strong\u003e peak starting\/locked-rotor current, and a \u003cstrong\u003e35A\u003c\/strong\u003e recommended breaker. A qualified electrician must verify conductor sizing, protection and local code requirements. The unit weighs \u003cstrong\u003e1,131 lb uncrated\u003c\/strong\u003e and \u003cstrong\u003e1,280 lb crated\u003c\/strong\u003e; plan unloading and placement accordingly.\u003c\/p\u003e\n\u003chr style=\"border:0;border-top:1px solid #ddd;margin:24px 0;\"\u003e\n\u003ch2 style=\"font-size:20px;font-weight:700;margin:25px 0 13px;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;font-size:16px;\"\u003e\u003ctbody\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px;width:42%;\"\u003eModel \/ SKU\u003c\/th\u003e\n\u003ctd style=\"padding:10px;\"\u003eESP15V120Y3-460\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;background:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px;width:42%;\"\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd style=\"padding:10px;\"\u003eE01PSXXP15V120Y460X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px;width:42%;\"\u003eUPC\u003c\/th\u003e\n\u003ctd style=\"padding:10px;\"\u003e810070054090\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;background:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px;width:42%;\"\u003eSeries\u003c\/th\u003e\n\u003ctd style=\"padding:10px;\"\u003eE450 Silent Air\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px;width:42%;\"\u003ePower\u003c\/th\u003e\n\u003ctd style=\"padding:10px;\"\u003e15 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;background:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px;width:42%;\"\u003eAirflow\u003c\/th\u003e\n\u003ctd style=\"padding:10px;\"\u003e58 CFM (manufacturer model sheet; 2026 pricing matrix lists 57 CFM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px;width:42%;\"\u003eMaximum Pressure\u003c\/th\u003e\n\u003ctd style=\"padding:10px;\"\u003e175 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;background:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px;width:42%;\"\u003eVoltage\u003c\/th\u003e\n\u003ctd style=\"padding:10px;\"\u003e460V three-phase (manufacturer ±10%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px;width:42%;\"\u003eAir Receiver\u003c\/th\u003e\n\u003ctd style=\"padding:10px;\"\u003e120-gallon vertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;background:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px;width:42%;\"\u003eMotor\u003c\/th\u003e\n\u003ctd style=\"padding:10px;\"\u003eTEFC, 1,740 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px;width:42%;\"\u003eFull Load Amps + 1.15 Service Factor\u003c\/th\u003e\n\u003ctd style=\"padding:10px;\"\u003e20.90 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;background:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px;width:42%;\"\u003ePeak Starting \/ Locked-Rotor Current\u003c\/th\u003e\n\u003ctd style=\"padding:10px;\"\u003e118 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px;width:42%;\"\u003eRecommended Breaker\u003c\/th\u003e\n\u003ctd style=\"padding:10px;\"\u003e35 A, verify installation requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;background:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px;width:42%;\"\u003ePump Model\u003c\/th\u003e\n\u003ctd style=\"padding:10px;\"\u003eAPP3Y2062TP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px;width:42%;\"\u003ePump Design\u003c\/th\u003e\n\u003ctd style=\"padding:10px;\"\u003eTwo-stage, pressure-lubricated cast iron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;background:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px;width:42%;\"\u003ePump Speed\u003c\/th\u003e\n\u003ctd style=\"padding:10px;\"\u003e815 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px;width:42%;\"\u003ePump Riser\u003c\/th\u003e\n\u003ctd style=\"padding:10px;\"\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;background:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px;width:42%;\"\u003eMagnetic Starter\u003c\/th\u003e\n\u003ctd style=\"padding:10px;\"\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px;width:42%;\"\u003eBelt Tensioner\u003c\/th\u003e\n\u003ctd style=\"padding:10px;\"\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;background:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px;width:42%;\"\u003eAutomatic Receiver Drain\u003c\/th\u003e\n\u003ctd style=\"padding:10px;\"\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px;width:42%;\"\u003eSilent Air\u003c\/th\u003e\n\u003ctd style=\"padding:10px;\"\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;background:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px;width:42%;\"\u003eSmart Air \/ Radiator\u003c\/th\u003e\n\u003ctd style=\"padding:10px;\"\u003eNot included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px;width:42%;\"\u003eOutlet Connection\u003c\/th\u003e\n\u003ctd style=\"padding:10px;\"\u003e1 inch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;background:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px;width:42%;\"\u003eBelt Count\u003c\/th\u003e\n\u003ctd style=\"padding:10px;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px;width:42%;\"\u003eOil Capacity\u003c\/th\u003e\n\u003ctd style=\"padding:10px;\"\u003e3 quarts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;background:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px;width:42%;\"\u003eUncrated Weight\u003c\/th\u003e\n\u003ctd style=\"padding:10px;\"\u003e1,131 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px;width:42%;\"\u003eCrated Weight\u003c\/th\u003e\n\u003ctd style=\"padding:10px;\"\u003e1,280 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;background:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px;width:42%;\"\u003eCrated Dimensions\u003c\/th\u003e\n\u003ctd style=\"padding:10px;\"\u003e48 in L × 46 in W; height not supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px;width:42%;\"\u003eService Kit\u003c\/th\u003e\n\u003ctd style=\"padding:10px;\"\u003eEFKIT009AWB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;background:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px;width:42%;\"\u003eCertifications\u003c\/th\u003e\n\u003ctd style=\"padding:10px;\"\u003eETL, ASME, CRN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px solid #ddd;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:10px;width:42%;\"\u003eEstimated Pump Life\u003c\/th\u003e\n\u003ctd style=\"padding:10px;\"\u003e70,000 hours (manufacturer estimate; maintenance-dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003chr style=\"border:0;border-top:1px solid #ddd;margin:24px 0;\"\u003e\n\u003ch2 style=\"font-size:20px;font-weight:700;margin:25px 0 13px;\"\u003eChoose the Right System\u003c\/h2\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eA 120-gallon receiver increases stored air for short peaks but does not increase sustained CFM. For moisture-sensitive equipment, pair the compressor with a properly sized \u003ca href=\"https:\/\/www.compressedairadvisors.com\/collections\/air-dryers\"\u003eair dryer\u003c\/a\u003e and \u003ca href=\"https:\/\/www.compressedairadvisors.com\/collections\/in-line-air-filters-and-water-separators\"\u003ecompressed-air filtration\u003c\/a\u003e. Find \u003ca href=\"https:\/\/www.compressedairadvisors.com\/collections\/maintenance\"\u003emaintenance supplies\u003c\/a\u003e for scheduled service.\u003c\/p\u003e\n\u003chr style=\"border:0;border-top:1px solid #ddd;margin:24px 0;\"\u003e\n\u003ch2 style=\"font-size:20px;font-weight:700;margin:25px 0 13px;\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003e\u003cstrong\u003eHow much air does this compressor supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eThe current EMAX model sheet lists 58 CFM; the September 2026 pricing file lists 57 CFM. Both sources list the model as a 15 HP unit. Verify the final published airflow rating with EMAX before release.\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003e\u003cstrong\u003eDoes this model operate on 230V?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eNo. ESP15V120Y3-460 is the 460V three-phase configuration. A separate 208\/230V model is available.\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003e\u003cstrong\u003eWhat pump and motor does it use?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eEMAX specifies the APP3Y2062TP pressure-lubricated two-stage pump at 815 RPM, paired with a 1,740 RPM TEFC motor.\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003e\u003cstrong\u003eWhat circuit protection is recommended?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eThe manufacturer lists a 35A recommended breaker, 20.90A full-load current with service factor, and 118A starting\/locked-rotor current. A qualified electrician should validate the installation.\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003e\u003cstrong\u003eDoes it include a magnetic starter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eYes. EMAX identifies a magnetic starter on this model.\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003e\u003cstrong\u003eWhat are the benefits of pressure lubrication?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eA gear-driven oil pump circulates filtered oil to crankshaft and connecting-rod wear points through drilled passages, rather than depending solely on splash lubrication.\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003e\u003cstrong\u003eIs the tank drain automatic?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eYes. An adjustable timed condensate drain is fitted to the air receiver.\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003e\u003cstrong\u003eCan it run continuously?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eVerify the exact head-unloader arrangement and acceptable duty cycle for continuous-run applications. Do not infer a 100% duty-cycle rating from the listed features.\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003e\u003cstrong\u003eWhich service kit and oil quantity apply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eThe listed service kit is EFKIT009AWB and the pump holds 3 quarts of oil. Follow the official EMAX maintenance schedule.\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:1.65;margin:0 0 16px;\"\u003eFor application sizing assistance, call \u003cstrong\u003e877-247-2381\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"How much air does this compressor supply?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"The current EMAX model sheet lists 58 CFM; the September 2026 pricing file lists 57 CFM. Both sources list the model as a 15 HP unit. Verify the final published airflow rating with EMAX before release.\"}},{\"@type\":\"Question\",\"name\":\"Does this model operate on 230V?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"No. ESP15V120Y3-460 is the 460V three-phase configuration. A separate 208\/230V model is available.\"}},{\"@type\":\"Question\",\"name\":\"What pump and motor does it use?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"EMAX specifies the APP3Y2062TP pressure-lubricated two-stage pump at 815 RPM, paired with a 1,740 RPM TEFC motor.\"}},{\"@type\":\"Question\",\"name\":\"What circuit protection is recommended?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"The manufacturer lists a 35A recommended breaker, 20.90A full-load current with service factor, and 118A starting\/locked-rotor current. A qualified electrician should validate the installation.\"}},{\"@type\":\"Question\",\"name\":\"Does it include a magnetic starter?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. EMAX identifies a magnetic starter on this model.\"}},{\"@type\":\"Question\",\"name\":\"What are the benefits of pressure lubrication?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"A gear-driven oil pump circulates filtered oil to crankshaft and connecting-rod wear points through drilled passages, rather than depending solely on splash lubrication.\"}},{\"@type\":\"Question\",\"name\":\"Is the tank drain automatic?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. An adjustable timed condensate drain is fitted to the air receiver.\"}},{\"@type\":\"Question\",\"name\":\"Can it run continuously?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Verify the exact head-unloader arrangement and acceptable duty cycle for continuous-run applications. Do not infer a 100% duty-cycle rating from the listed features.\"}},{\"@type\":\"Question\",\"name\":\"Which service kit and oil quantity apply?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"The listed service kit is EFKIT009AWB and the pump holds 3 quarts of oil. Follow the official EMAX maintenance schedule.\"}}]}\u003c\/script\u003e\n\u003c\/div\u003e","brand":"EMAX","offers":[{"title":"Default Title","offer_id":50842556858438,"sku":"ESP15V120Y3-460","price":8702.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0014\/6237\/0374\/files\/ESP15V120Y3-460-1-3-scaled_93fcf8bf-bd98-43c0-b248-0c0139708946.jpg?v=1793221302","url":"https:\/\/www.compressedairadvisors.com\/products\/emax-esp15v120y3-460-15-hp-silent-air-58-cfm-460v-3ph","provider":"Compressed Air Advisors Online, Inc. ","version":"1.0","type":"link"}