{"product_id":"hankison-vnca100-fp-100-scfm-refrigerated-air-dryer","title":"Hankison VNCA100-FP Non-Cycling Refrigerated Air Dryer – 100 SCFM, 115V\/1Ph with Pre \u0026 Post Filtration","description":"\u003ch1\u003e\u003cspan\u003eHankison VNCA100-FP Non-Cycling Refrigerated Air Dryer – 100 SCFM, 115V\/1Ph with Pre \u0026amp; Post Filtration\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan\u003eReliable Compressed Air Drying with Complete Pre \u0026amp; Post Filtration\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eHankison VNCA100-FP Non-Cycling Refrigerated Air Dryer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e provides dependable moisture removal and filtration for compressed air systems requiring up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e100 SCFM\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e of treated air. Designed for industrial compressed air applications, the VNCA100-FP combines refrigerated air drying with matched Hankison pre and post filtration in one complete air treatment package.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eOperating on convenient \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e115V single-phase power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, the VNCA100-FP uses \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eR513A low-GWP refrigerant\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and consumes just \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e0.55 kW\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e at full rated capacity. Its compact footprint makes it an excellent choice for compressor rooms, manufacturing facilities, machine shops, maintenance departments, and other facilities where reliable moisture control is required.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe VNCA100-FP includes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eHankison F07-PF-DP1 prefilter and F07-HF-DP1 afterfilter\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, providing filtration before and after the refrigerated dryer for cleaner, drier compressed air throughout your system.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features \u0026amp; Benefits\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan\u003e100 SCFM Rated Capacity\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003eRated for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e100 SCFM\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDesigned for medium-size industrial compressed air systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHelps remove moisture before it reaches downstream piping and equipment\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRated in accordance with ISO 7183 Option A2 conditions\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eComplete Pre \u0026amp; Post Filtration Package\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003ePre and post filtration included\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003ePrefilter: F07-PF-DP1\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003eAfterfilter: F07-HF-DP1\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePrefiltration helps protect the dryer from incoming contaminants\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAfterfiltration provides additional compressed air treatment downstream\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eComplete dryer and filtration package eliminates the need to separately select matching filters\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eNon-Cycling Refrigerated Dryer Design\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eProven non-cycling refrigerated drying technology\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProvides continuous moisture removal during operation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHelps reduce water-related problems in compressed air piping and equipment\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eStraightforward design for dependable industrial operation\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eR513A Refrigerant\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003eUses \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eR513A refrigerant\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLow-GWP refrigerant designed for improved environmental sustainability\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProvides efficient refrigerated dryer performance\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eLow Power Consumption\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003eConsumes only \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e0.55 kW\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProvides effective compressed air drying with low electrical demand\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDesigned for efficient operation at full rated capacity\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003e115V Single-Phase Power\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003e115V \/ 1Ph \/ 60 Hz\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eNo three-phase electrical service required\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMakes installation easier in shops and facilities with standard single-phase power\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eExpands installation flexibility compared with larger three-phase-only dryers\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eCompact Industrial Design\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003e21.0\" W x 22.6\" D x 25.0\" H\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eApproximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e92 lbs.\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCompact footprint allows flexible installation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003e3\/4\" female NPT\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e inlet and outlet connections\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eCondensate Removal\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eCondensate drain furnished with the dryer\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003e1\/8\" FNPT drain connection\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRemoves moisture collected during the refrigeration process\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHelps maintain dependable dryer operation\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eUL \u0026amp; CSA Certified\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eThird-party certified to applicable UL and CSA standards\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDesigned for safe operation in the United States and Canada\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eIdeal Applications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Hankison VNCA100-FP is well suited for:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eManufacturing facilities\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMachine shops\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCNC equipment\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAutomotive and service shops\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eWoodworking facilities\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMaintenance departments\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePackaging equipment\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePneumatic tools and controls\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRotary screw compressor systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eReciprocating compressor systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eGeneral industrial compressed air systems\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eHankison VNCA100-FP\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eRated Air Flow\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 SCFM\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eMetric Air Flow\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e170 Nm³\/H\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDryer Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNon-Cycling Refrigerated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eVoltage\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e115V \/ 1Ph \/ 60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.55 kW\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eRefrigerant\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eR513A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eAir Inlet \/ Outlet\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3\/4\" Female NPT\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eCondensate Drain Connection\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1\/8\" FNPT\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eWidth\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e21.0\"\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDepth\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e22.6\"\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eHeight\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25.0\"\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eShipping Weight\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e92 lbs.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003ePrefilter\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eF07-PF-DP1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eAfterfilter\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eF07-HF-DP1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eFiltration\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePre \u0026amp; Post Filtration Included\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eFrequently Asked Questions\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan\u003eHow much compressed air can the Hankison VNCA100-FP handle?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Hankison VNCA100-FP is rated for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e100 SCFM\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e under ISO 7183 Option A2 rating conditions. Actual capacity can vary depending on operating pressure, compressed air inlet temperature, ambient temperature, and airflow demand.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eDoes the VNCA100-FP include air filters?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eYes. The VNCA100-FP includes both a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eHankison F07-PF-DP1 prefilter\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eF07-HF-DP1 afterfilter\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, providing filtration before and after the refrigerated dryer.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWhy is pre and post filtration important?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe prefilter helps remove contaminants before compressed air enters the dryer, helping protect the dryer and improve overall air treatment. The afterfilter provides additional filtration before compressed air enters the facility's distribution system or downstream equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWhat voltage does the VNCA100-FP require?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe VNCA100-FP operates on \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e115V \/ 1-phase \/ 60 Hz power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, allowing installation without the need for three-phase electrical service.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWhat size air connections does the VNCA100-FP use?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe dryer uses \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3\/4-inch female NPT inlet and outlet connections\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWhat refrigerant does the Hankison VNCA100 use?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe VNCA100 uses \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eR513A refrigerant\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, a low-GWP refrigerant designed to provide efficient refrigerated drying while supporting improved environmental sustainability.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWhat are the rated conditions for the VNCA100-FP?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eHankison rates VNCA Series capacity in accordance with \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eISO 7183 Option A2\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e at:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e100 PSIG inlet pressure\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e100°F compressed air inlet temperature\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e100°F ambient temperature\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e60 Hz electrical supply\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eDoes the VNCA100-FP include a condensate drain?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eYes. The VNCA100-FP is furnished with a condensate drain to efficiently remove moisture separated from the compressed air.\u003c\/span\u003e\u003c\/p\u003e","brand":"SPX Hankison","offers":[{"title":"Default Title","offer_id":46376783544390,"sku":"VNCA100-FP","price":2666.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0014\/6237\/0374\/files\/VNCA50_HERO-2.png?v=1787256240","url":"https:\/\/www.compressedairadvisors.com\/products\/hankison-vnca100-fp-100-scfm-refrigerated-air-dryer","provider":"Compressed Air Advisors Online, Inc. ","version":"1.0","type":"link"}