{"product_id":"hankison-vnca32-fp-32-scfm-refrigerated-air-dryer","title":"Hankison VNCA32-FP Non-Cycling Refrigerated Air Dryer – 32 SCFM, 115V\/1Ph with Pre \u0026 After Filtration","description":"\u003ch1\u003e\u003cspan\u003eHankison VNCA32-FP Non-Cycling Refrigerated Air Dryer – 32 SCFM, 115V\/1Ph with Pre \u0026amp; Post Filtration\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan\u003eReliable Compressed Air Drying with Complete Pre \u0026amp; Post Filtration\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eHankison VNCA32-FP Non-Cycling Refrigerated Air Dryer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e provides dependable moisture removal and filtration for compressed air systems requiring up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e32 SCFM\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e of treated air. Designed for industrial shops, manufacturing equipment, pneumatic tools, and other compressed air applications, the VNCA32-FP combines efficient refrigerated air drying with matched Hankison pre and post filtration in one complete air treatment package.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eOperating on convenient \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e115V single-phase power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, the VNCA32-FP uses \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eR513A low-GWP refrigerant\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and consumes just 0.26 kW at full rated capacity. Its compact footprint makes it easy to incorporate into smaller compressor rooms, equipment areas, and point-of-use compressed air installations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe VNCA32-FP includes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eHankison F04-PF-DP1 prefilter and F04-HF-DP1 afterfilter\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, providing filtration before and after the refrigerated dryer for cleaner, drier compressed air throughout your system.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features \u0026amp; Benefits\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan\u003e32 SCFM Rated Capacity\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003eRated for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e32 SCFM\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDesigned for smaller industrial and commercial compressed air systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHelps remove moisture before it reaches downstream piping and equipment\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRated in accordance with ISO 7183 Option A2 conditions\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eComplete Pre \u0026amp; Post Filtration Package\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003ePre and post filtration included\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003ePrefilter: F04-PF-DP1\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003eAfterfilter: F04-HF-DP1\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePrefiltration helps protect the dryer from incoming contaminants\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAfterfiltration provides additional compressed air treatment downstream\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eComplete dryer and filtration package eliminates the need to separately select matching filters\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eNon-Cycling Refrigerated Dryer Design\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eProven non-cycling refrigerated drying technology\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProvides continuous moisture removal during operation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHelps reduce water-related problems in compressed air piping\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSimple, dependable design for industrial applications\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eR513A Refrigerant\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003eUses modern \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eR513A refrigerant\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLower global warming potential than many traditional refrigerants\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDesigned for efficient refrigerated dryer performance\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eLow Power Consumption\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003eConsumes only \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e0.26 kW\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProvides effective compressed air drying with minimal electrical demand\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eWell suited for smaller compressed air systems\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003e115V Single-Phase Power\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003e115V \/ 1Ph \/ 60 Hz\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eNo three-phase electrical service required\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eConvenient for shops, maintenance departments, and smaller facilities\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eCompact Industrial Design\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003e17.9\" W x 20.2\" D x 21\" H\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eApproximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e62 lbs.\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCompact footprint allows flexible installation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003e1\/2\" female NPT\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e inlet and outlet connections\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eIntegrated Condensate Removal\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eCondensate drain included\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAutomatically removes moisture separated during the refrigeration process\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHelps maintain consistent dryer performance\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eUL \u0026amp; CSA Certified\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eThird-party certified to applicable UL and CSA standards\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDesigned for safe operation in the United States and Canada\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eIdeal Applications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Hankison VNCA32-FP is ideal for:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eAutomotive repair and service shops\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMachine shops\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCNC equipment\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eWoodworking and cabinet shops\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLight manufacturing\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePneumatic tools\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePneumatic controls and actuators\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMaintenance departments\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePackaging equipment\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSmall rotary screw compressor systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eReciprocating air compressor systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eGeneral industrial compressed air\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eHankison VNCA32-FP\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eRated Air Flow\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32 SCFM\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eMetric Air Flow\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e54 Nm³\/H\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDryer Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNon-Cycling Refrigerated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eVoltage\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e115V \/ 1Ph \/ 60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.26 kW\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eRefrigerant\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eR513A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eAir Inlet \/ Outlet\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1\/2\" Female NPT\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eWidth\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e17.9\"\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDepth\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20.2\"\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eHeight\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e21.0\"\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eShipping Weight\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e62 lbs.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003ePrefilter\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eF04-PF-DP1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eAfterfilter\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eF04-HF-DP1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eFiltration\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePre \u0026amp; Post Filtration Included\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eFrequently Asked Questions\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan\u003eHow much compressed air can the Hankison VNCA32-FP handle?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Hankison VNCA32-FP is rated for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e32 SCFM\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e under ISO 7183 Option A2 rating conditions. Actual dryer capacity can vary depending on operating pressure, compressed air inlet temperature, ambient temperature, and airflow demand.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eDoes the VNCA32-FP include air filters?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eYes. The VNCA32-FP includes both a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eHankison F04-PF-DP1 prefilter\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eF04-HF-DP1 afterfilter\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, providing filtration before and after the refrigerated dryer.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWhy is pre and post filtration important?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe prefilter helps remove contaminants before compressed air enters the dryer, helping protect the dryer and improve air treatment performance. The afterfilter provides additional filtration before compressed air enters the facility's distribution system or downstream equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWhat voltage does the VNCA32-FP require?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe VNCA32-FP operates on \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e115V single-phase, 60 Hz power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, making it convenient for facilities without three-phase electrical service.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWhat size air connections does the VNCA32-FP use?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe dryer uses \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1\/2-inch female NPT inlet and outlet connections\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWhat refrigerant does the VNCA32 use?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe VNCA32 uses \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eR513A low-GWP refrigerant\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, designed to provide efficient refrigerated drying while improving environmental sustainability.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWhat are the rated conditions for the VNCA32-FP?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eHankison rates the VNCA Series in accordance with \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eISO 7183 Option A2\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e at:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e100 PSIG inlet pressure\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e100°F compressed air inlet temperature\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e100°F ambient temperature\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e60 Hz electrical supply\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eDoes the VNCA32-FP include a condensate drain?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eYes. The VNCA Series is furnished with a condensate drain to efficiently remove moisture separated from the compressed air.\u003c\/span\u003e\u003c\/p\u003e","brand":"SPX Hankison","offers":[{"title":"Default Title","offer_id":46373992005702,"sku":"VNCA32-FP","price":1701.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0014\/6237\/0374\/files\/VNCA50_HERO-2.png?v=1787256240","url":"https:\/\/www.compressedairadvisors.com\/products\/hankison-vnca32-fp-32-scfm-refrigerated-air-dryer","provider":"Compressed Air Advisors Online, Inc. ","version":"1.0","type":"link"}