{"product_id":"jorc-mag-11-zero-air-loss-condensate-drain-3954-3964","title":"JORC MAG-11 3954 \/ 3964 Zero Air Loss Condensate Drain, 1\/2\" NPT","description":"\u003cdiv class=\"content top clearfix\"\u003e\n\u003ch1\u003e\u003cspan\u003eJORC MAG-11 3954 \/ 3964 Zero Air Loss Condensate Drain, 1\/2\" NPT\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe JORC MAG-11 is a magnetically operated zero-air-loss condensate drain designed for refrigerated air dryers, aftercoolers, moisture separators, piston compressors, and other compressed air applications. It automatically removes accumulated condensate without intentionally releasing valuable compressed air.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eUnlike timer-operated and electrically operated drains, the MAG-11 requires no electricity, control air, batteries, or external power source. Its internal magnetic level-sensing system opens the direct-acting drain valve only when condensate needs to be discharged.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe compact aluminum housing includes both top and side 1\/2\" NPT inlet connections, providing greater installation flexibility in tight spaces. A rotatable bottom outlet also makes it easier to route the condensate discharge tubing.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eChoose between the standard MAG-11 drain or the version equipped with a manual test button:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003ePart 3954:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Standard MAG-11 zero-air-loss drain\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003ePart 3964:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e MAG-11 zero-air-loss drain with manual test button\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eAvailable Models\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan\u003eJORC 3954 Standard MAG-11\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe standard 3954 provides fully automatic, magnetically operated condensate removal without requiring electricity or control air.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eJORC 3964 MAG-11 with Test Button\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe 3964 includes a manual test button that allows maintenance personnel to check that the drain opening is clear and operating correctly. The test button can also be used to help depressurize the drain before performing routine maintenance.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eMagnetically operated zero-air-loss condensate drain\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRequires no electricity or control air\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAutomatically discharges condensate based on liquid level\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTwo 1\/2\" NPT inlet positions\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTop and side inlet connections provide installation flexibility\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCompact design for tight installation areas\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eReliable 2\/2-way direct-acting valve\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBuilt-in air-lock prevention\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRotatable bottom outlet\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCorrosion-resistant aluminum housing\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eServiceable valve assembly\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eService kits available\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eNo timer settings or programming required\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOptional manual test button available on part 3964\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eManufacturer:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e JORC Industrial\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eProduct Series:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e MAG-11\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eStandard Part Number:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 3954\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eTest-Button Part Number:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 3964\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eDrain Type:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Magnetically operated zero-air-loss drain\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003ePressure Range:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 0 to 230 PSI\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eMaximum Drainage Capacity:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 38 gallons per hour at 230 PSI\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eInlet Connections:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Two 1\/2\" NPT inlet positions\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eInlet Configuration:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Top and side\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eOutlet Connection:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 1\/8\" with hose connector\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eValve Type:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 2\/2-way direct acting\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eValve Seals:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e FPM\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eMedium Temperature Range:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 34°F to 122°F\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eAmbient Temperature Range:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 34°F to 122°F\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eInlet Height:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 3.9\"\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eEnvironmental Protection:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e NEMA 6 \/ IP68\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eHousing Material:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Corrosion-resistant aluminum with EP coating\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003ePower Required:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e None\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eControl Air Required:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e None\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eServiceable Valve:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Yes\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eTest Feature:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Included with part 3964\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eIdeal Applications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe JORC MAG-11 is suitable for condensate removal from:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eRefrigerated compressed air dryers\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCompressed air aftercoolers\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMoisture separators\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eWater separators\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePiston air compressors\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAir receiver tanks\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCompressed air filters\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOther compressed air condensate collection points\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eWhy Choose a Zero-Air-Loss Drain?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eTimer-operated drains open at programmed intervals, regardless of whether condensate is present. This can allow compressed air to escape every time the valve opens.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe JORC MAG-11 responds to the actual condensate level. It opens when liquid needs to be discharged and closes without intentionally bleeding compressed air from the system. Reducing unnecessary air loss can help decrease compressor runtime, lower energy consumption, and maintain more consistent system pressure.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eChoosing Between the 3954 and 3964\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eChoose the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3954 standard model\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e when you need reliable automatic condensate drainage without electricity or control air.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eChoose the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3964 test-button model\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e when maintenance personnel need a convenient way to:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eManually check the drain opening\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eConfirm that the discharge orifice is not obstructed\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAssist with depressurizing the drain before service\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePerform routine maintenance checks more easily\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe test button does not change the drain’s automatic operation. Both models use the same magnetic level-sensing technology and provide zero-air-loss condensate discharge.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eFrequently Asked Questions\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan\u003eDoes the JORC MAG-11 require electricity?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eNo. The MAG-11 operates through magnetic level-sensing technology and does not require electricity, batteries, control air, or an external power source.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eIs the MAG-11 a zero-air-loss drain?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eYes. It discharges condensate based on the liquid level and is designed to close without intentionally releasing compressed air.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWhat is the difference between parts 3954 and 3964?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePart 3954 is the standard MAG-11. Part 3964 includes a manual test button for checking the drain opening and assisting with depressurization during maintenance.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eDoes the 3964 operate automatically?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eYes. The 3964 operates automatically just like the standard 3954. The test button is an additional manual maintenance feature and does not need to be pressed during normal operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWhat equipment can the MAG-11 be installed on?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe MAG-11 is commonly installed on refrigerated dryers, aftercoolers, moisture separators, piston compressors, receiver tanks, and other compressed air condensate collection points.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWhat is the maximum operating pressure?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBoth versions operate at pressures from 0 to 230 PSI.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eHow much condensate can the MAG-11 discharge?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe maximum rated drainage capacity is 38 gallons per hour at 230 PSI.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eHow many inlet connections does it have?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe MAG-11 has two 1\/2\" NPT inlet positions. One inlet is located on the top and the other is located on the side, allowing the installer to select the connection that best fits the application.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eCan the discharge outlet be repositioned?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eYes. The bottom outlet can be rotated 360 degrees to simplify installation and discharge-tubing placement.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eCan the valve be serviced?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eYes. The direct-acting valve is serviceable, and replacement service kits are available.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eDoes the drain require programming?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eNo. There are no timers, intervals, or operating settings to program. Condensate discharge is controlled automatically by the internal magnetic level-sensing system\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Jorc","offers":[{"title":"3954 – Standard","offer_id":46090793680966,"sku":"3954","price":239.0,"currency_code":"USD","in_stock":true},{"title":"3964 – With Test Button","offer_id":46090793713734,"sku":"3964","price":289.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0014\/6237\/0374\/products\/Mini-Mag.jpg?v=1533838658","url":"https:\/\/www.compressedairadvisors.com\/products\/jorc-mag-11-zero-air-loss-condensate-drain-3954-3964","provider":"Compressed Air Advisors Online, Inc. ","version":"1.0","type":"link"}