{"product_id":"tsunami-20-cfm-3-stage-membrane-dryer-21999-0524","title":"Tsunami 20 CFM 3-Stage Membrane Dryer, 21999-0524","description":"\u003cdiv style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;\"\u003e\n\u003ch2 style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;font-size:22px !important;line-height:1.35 !important;margin:28px 0 18px !important;\"\u003eTsunami 20 CFM 3-Stage Membrane Dryer, 21999-0524\u003c\/h2\u003e\n\u003cp style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;margin:0 0 16px !important;\"\u003eSupply clean, dry air close to your equipment with the \u003cstrong\u003eTsunami 21999-0524 20 CFM membrane dryer\u003c\/strong\u003e. The Precision package combines water separation, oil coalescing and activated carbon filtration before the membrane stage to address liquid water, oil aerosols, fine particles and oil vapor. An outlet regulator lets you set delivery pressure for the application.\u003c\/p\u003e\n\u003cp style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;margin:0 0 16px !important;\"\u003eThe membrane drying process operates pneumatically, while the included \u003cstrong\u003eelectronic condensate drain requires 120 VAC\u003c\/strong\u003e. Choose this three-stage package when your application calls for activated carbon filtration in addition to moisture removal.\u003c\/p\u003e\n\u003ch2 style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;font-size:22px !important;margin:28px 0 18px !important;\"\u003eWhy Choose a Membrane Dryer?\u003c\/h2\u003e\n\u003cp style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;margin:0 0 16px !important;\"\u003eA membrane dryer is a practical choice when you need \u003cstrong\u003ea compact supply of dry air at one machine or work area\u003c\/strong\u003e. Its strongest advantages are a simple drying mechanism, small installation footprint and the ability to treat a specific air branch to the dryness that application needs.\u003c\/p\u003e\n\u003cul style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;list-style-type:disc !important;padding-left:26px !important;\"\u003e\n\u003cli style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;display:list-item !important;margin:0 0 8px !important;\"\u003e\n\u003cstrong\u003eOne tool or process needs drier air:\u003c\/strong\u003e Add treatment at a paint station, small pneumatic assembly or instrument air branch instead of specifying the same low dew point for every air user in the shop.\u003c\/li\u003e\n\u003cli style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;display:list-item !important;margin:0 0 8px !important;\"\u003e\n\u003cstrong\u003eLimited installation space:\u003c\/strong\u003e A compact membrane package can be mounted near the equipment it serves.\u003c\/li\u003e\n\u003cli style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;display:list-item !important;margin:0 0 8px !important;\"\u003e\n\u003cstrong\u003ePneumatic drying with a powered drain:\u003c\/strong\u003e The drying core needs no electrical power, but this Precision package requires 120 VAC for its electronic drain.\u003c\/li\u003e\n\u003cli style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;display:list-item !important;margin:0 0 8px !important;\"\u003e\n\u003cstrong\u003eNo routine desiccant cartridge changes:\u003c\/strong\u003e The membrane uses hollow fibers rather than a replaceable bed of drying beads. Filter elements still require scheduled service, and a damaged or oil-contaminated membrane core may need replacement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;font-size:20px !important;margin:24px 0 14px !important;\"\u003eMembrane vs. Refrigerated Dryers\u003c\/h3\u003e\n\u003cp style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;margin:0 0 16px !important;\"\u003eA refrigerated dryer is often the economical choice for general shop air and larger, steady airflow when an above-freezing pressure dew point meets the application. Choose membrane drying when a small point of use needs additional drying, installation space is tight or a refrigeration unit at that location is inconvenient. A properly sized membrane can also serve downstream of a central refrigerated dryer, with appropriate pre-filtration, to further dry a selected branch.\u003c\/p\u003e\n\u003ch3 style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;font-size:20px !important;margin:24px 0 14px !important;\"\u003eMembrane vs. Desiccant Dryers\u003c\/h3\u003e\n\u003cp style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;margin:0 0 16px !important;\"\u003eCompared with a regenerative desiccant dryer, a membrane drying core avoids alternating tower controls and desiccant-bed maintenance. Compared with a manual-change cartridge dryer such as CORE, it avoids routine replacement of a saturated desiccant cartridge. A regenerative desiccant system is often the better fit when continuous production requires a specified very low pressure dew point or substantially more airflow. A manual-change cartridge dryer can suit intermittent use when cartridge replacement is acceptable.\u003c\/p\u003e\n\u003ch3 style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;font-size:20px !important;margin:24px 0 14px !important;\"\u003eWhat Is the Tradeoff?\u003c\/h3\u003e\n\u003cp style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;margin:0 0 16px !important;\"\u003e\u003cstrong\u003eMembrane drying uses compressed air to remove moisture.\u003c\/strong\u003e Sweep-air consumption adds to compressor demand, so no electrical power at the drying core does not mean zero energy cost. Compare usable outlet flow, required dryness, hours of operation and maintenance costs. At larger or continuous loads, sweep-air cost can outweigh the installation advantages. Adequate water separation and coalescing filtration are essential to protect the fibers.\u003c\/p\u003e\n\u003ch2 style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;font-size:22px !important;margin:28px 0 18px !important;\"\u003eWhich Dryer Fits Your Application?\u003c\/h2\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;margin:0 0 24px;\"\u003e\u003ctable style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;width:100%;border-collapse:collapse;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;text-align:left;background:#f1f4f7;padding:12px 14px;border:1px solid #d9dde2;\"\u003eDryer type\u003c\/th\u003e\n\u003cth style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;text-align:left;background:#f1f4f7;padding:12px 14px;border:1px solid #d9dde2;\"\u003eWhen it makes sense\u003c\/th\u003e\n\u003cth style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;text-align:left;background:#f1f4f7;padding:12px 14px;border:1px solid #d9dde2;\"\u003eOperating consideration\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;text-align:left;vertical-align:top;padding:12px 14px;border:1px solid #d9dde2;\"\u003eMembrane\u003c\/td\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;text-align:left;vertical-align:top;padding:12px 14px;border:1px solid #d9dde2;\"\u003eCompact point-of-use treatment; selected branches needing extra drying\u003c\/td\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;text-align:left;vertical-align:top;padding:12px 14px;border:1px solid #d9dde2;\"\u003eUses sweep air; outlet dryness depends on flow and inlet conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;text-align:left;vertical-align:top;padding:12px 14px;border:1px solid #d9dde2;\"\u003eRefrigerated\u003c\/td\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;text-align:left;vertical-align:top;padding:12px 14px;border:1px solid #d9dde2;\"\u003eGeneral-purpose shop or central air when an above-freezing dew point is sufficient\u003c\/td\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;text-align:left;vertical-align:top;padding:12px 14px;border:1px solid #d9dde2;\"\u003eRequires electrical power and refrigeration-system maintenance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;text-align:left;vertical-align:top;padding:12px 14px;border:1px solid #d9dde2;\"\u003eRegenerative desiccant\u003c\/td\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;text-align:left;vertical-align:top;padding:12px 14px;border:1px solid #d9dde2;\"\u003eContinuous duty with a specified low pressure dew point\u003c\/td\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;text-align:left;vertical-align:top;padding:12px 14px;border:1px solid #d9dde2;\"\u003eRegeneration uses purge air and\/or energy; valves and desiccant require service\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;text-align:left;vertical-align:top;padding:12px 14px;border:1px solid #d9dde2;\"\u003eManual-change desiccant \/ CORE\u003c\/td\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;text-align:left;vertical-align:top;padding:12px 14px;border:1px solid #d9dde2;\"\u003eIntermittent point-of-use work\u003c\/td\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;text-align:left;vertical-align:top;padding:12px 14px;border:1px solid #d9dde2;\"\u003eReplace the cartridge as it becomes saturated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;margin:0 0 16px !important;\"\u003eTell us the required pressure dew point, minimum downstream temperature, inlet pressure and actual tool airflow. We can help decide whether this membrane package, a refrigerated dryer or a desiccant system best matches your needs.\u003c\/p\u003e\n\u003ch2 style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;font-size:22px !important;line-height:1.35 !important;margin:28px 0 18px !important;\"\u003eKey Features and Benefits\u003c\/h2\u003e\n\u003cul style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;list-style-type:disc !important;padding-left:26px !important;\"\u003e\n\u003cli style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;display:list-item !important;margin:0 0 8px !important;\"\u003e\n\u003cstrong\u003e3 stages of pre-filtration:\u003c\/strong\u003e Water separator, oil coalescing filter and activated carbon filter.\u003c\/li\u003e\n\u003cli style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;display:list-item !important;margin:0 0 8px !important;\"\u003e\n\u003cstrong\u003eHollow-fiber membrane:\u003c\/strong\u003e Separates water vapor from compressed air for moisture-sensitive work.\u003c\/li\u003e\n\u003cli style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;display:list-item !important;margin:0 0 8px !important;\"\u003e\n\u003cstrong\u003eOutlet regulator:\u003c\/strong\u003e Adjust delivery pressure at the point of use.\u003c\/li\u003e\n\u003cli style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;display:list-item !important;margin:0 0 8px !important;\"\u003e\n\u003cstrong\u003eAutomatic condensate removal:\u003c\/strong\u003e 120V electronic drain.\u003c\/li\u003e\n\u003cli style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;display:list-item !important;margin:0 0 8px !important;\"\u003e\n\u003cstrong\u003eCompact installation:\u003c\/strong\u003e Wall-mounting brackets keep the system near the equipment it serves.\u003c\/li\u003e\n\u003cli style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;display:list-item !important;margin:0 0 8px !important;\"\u003e\n\u003cstrong\u003eReplaceable service components:\u003c\/strong\u003e Filter elements, regulators, drains and the membrane core are available separately.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;font-size:22px !important;line-height:1.35 !important;margin:28px 0 18px !important;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;margin:0 0 24px;\"\u003e\u003ctable style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;width:100%;border-collapse:collapse\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;background:#f1f4f7;text-align:left;padding:12px 14px;border:1px solid #d9dde2;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;background:#f1f4f7;text-align:left;padding:12px 14px;border:1px solid #d9dde2;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;text-align:left;vertical-align:top;padding:12px 14px;border:1px solid #d9dde2;\"\u003ePart number\u003c\/td\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;text-align:left;vertical-align:top;padding:12px 14px;border:1px solid #d9dde2;\"\u003e21999-0524\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;text-align:left;vertical-align:top;padding:12px 14px;border:1px solid #d9dde2;\"\u003eRated maximum airflow\u003c\/td\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;text-align:left;vertical-align:top;padding:12px 14px;border:1px solid #d9dde2;\"\u003e20 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;text-align:left;vertical-align:top;padding:12px 14px;border:1px solid #d9dde2;\"\u003ePre-filtration\u003c\/td\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;text-align:left;vertical-align:top;padding:12px 14px;border:1px solid #d9dde2;\"\u003e3 stages\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;text-align:left;vertical-align:top;padding:12px 14px;border:1px solid #d9dde2;\"\u003eInlet \/ outlet connections\u003c\/td\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;text-align:left;vertical-align:top;padding:12px 14px;border:1px solid #d9dde2;\"\u003e1\/2\" NPT \/ 1\/2\" NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;text-align:left;vertical-align:top;padding:12px 14px;border:1px solid #d9dde2;\"\u003eMaximum inlet air temperature\u003c\/td\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;text-align:left;vertical-align:top;padding:12px 14px;border:1px solid #d9dde2;\"\u003e100°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;text-align:left;vertical-align:top;padding:12px 14px;border:1px solid #d9dde2;\"\u003eMaximum operating pressure\u003c\/td\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;text-align:left;vertical-align:top;padding:12px 14px;border:1px solid #d9dde2;\"\u003e175 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;text-align:left;vertical-align:top;padding:12px 14px;border:1px solid #d9dde2;\"\u003eSweep-air consumption\u003c\/td\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;text-align:left;vertical-align:top;padding:12px 14px;border:1px solid #d9dde2;\"\u003e3.3 CFM at 100 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;text-align:left;vertical-align:top;padding:12px 14px;border:1px solid #d9dde2;\"\u003eCondensate drain\u003c\/td\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;text-align:left;vertical-align:top;padding:12px 14px;border:1px solid #d9dde2;\"\u003eElectronic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;text-align:left;vertical-align:top;padding:12px 14px;border:1px solid #d9dde2;\"\u003eElectrical supply\u003c\/td\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;text-align:left;vertical-align:top;padding:12px 14px;border:1px solid #d9dde2;\"\u003e120 VAC for electronic drain\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;text-align:left;vertical-align:top;padding:12px 14px;border:1px solid #d9dde2;\"\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;text-align:left;vertical-align:top;padding:12px 14px;border:1px solid #d9dde2;\"\u003e23\" x 23-1\/2\" x 5-1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;text-align:left;vertical-align:top;padding:12px 14px;border:1px solid #d9dde2;\"\u003eApproximate weight\u003c\/td\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;text-align:left;vertical-align:top;padding:12px 14px;border:1px solid #d9dde2;\"\u003e22 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;margin:0 0 16px !important;\"\u003eSelect capacity for the required outlet dryness, inlet conditions and actual process demand. Allow for sweep-air consumption in compressor sizing. Airflow and operating conditions affect the achievable dew point.\u003c\/p\u003e\n\u003cp style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;margin:0 0 16px !important;\"\u003e\u003cstrong\u003eSizing for greater dew-point suppression:\u003c\/strong\u003e For a 100°F dew-point reduction, use the recommended \u003cstrong\u003e6 SCFM application flow\u003c\/strong\u003e when sizing this model. The 20 CFM maximum rating is not a guarantee of that dryness at full flow. Call us to match capacity to your process.\u003c\/p\u003e\n\u003ch2 style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;font-size:22px !important;line-height:1.35 !important;margin:28px 0 18px !important;\"\u003eHow Membrane Drying Works\u003c\/h2\u003e\n\u003cp style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;margin:0 0 16px !important;\"\u003ePre-filtered air passes through hollow fibers. Water vapor permeates the fiber walls, and a portion of dried air sweeps the collected moisture out through the vents. This sweep flow is normal during operation and may sound like a small air leak.\u003c\/p\u003e\n\u003ch2 style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;font-size:22px !important;line-height:1.35 !important;margin:28px 0 18px !important;\"\u003eMaintenance Parts and Replacement Elements\u003c\/h2\u003e\n\u003cp style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;margin:0 0 16px !important;\"\u003eSelect the service part for this dryer and its filter series. Parts are sold separately; filter service kits, element packs and the membrane core are different replacement items.\u003c\/p\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;margin:0 0 24px;\"\u003e\u003ctable style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;width:100%;border-collapse:collapse\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;background:#f1f4f7;text-align:left;padding:12px 14px;border:1px solid #d9dde2;\"\u003ePart number\u003c\/th\u003e\n\u003cth style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;background:#f1f4f7;text-align:left;padding:12px 14px;border:1px solid #d9dde2;\"\u003eService item\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;text-align:left;vertical-align:top;padding:12px 14px;border:1px solid #d9dde2;\"\u003e\u003ca href=\"\/products\/tsunami-50-series-water-separator-service-kit-pn-21999-0227?variant=39302829441094\" style=\"color:#0056b3 !important;text-decoration:underline !important;\"\u003e21999-0227\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;text-align:left;vertical-align:top;padding:12px 14px;border:1px solid #d9dde2;\"\u003eWater separator service kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;text-align:left;vertical-align:top;padding:12px 14px;border:1px solid #d9dde2;\"\u003e\u003ca href=\"\/products\/tsunami-120-240-series-oil-coalescing-filter-service-kit-pn-21999-0202?variant=39302844317766\" style=\"color:#0056b3 !important;text-decoration:underline !important;\"\u003e21999-0202\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;text-align:left;vertical-align:top;padding:12px 14px;border:1px solid #d9dde2;\"\u003eOil coalescing filter service kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;text-align:left;vertical-align:top;padding:12px 14px;border:1px solid #d9dde2;\"\u003e\u003ca href=\"\/products\/tsunami-21999-0825-oil-coalescing-element-5-pack?variant=40192915865670\" style=\"color:#0056b3 !important;text-decoration:underline !important;\"\u003e21999-0825\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;text-align:left;vertical-align:top;padding:12px 14px;border:1px solid #d9dde2;\"\u003eOil coalescing replacement elements, five-pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;text-align:left;vertical-align:top;padding:12px 14px;border:1px solid #d9dde2;\"\u003e\u003ca href=\"\/products\/copy-of-copy-of-tsunami-50-series-activated-carbon-service-kit-pn-21999-0200?variant=39320341479494\" style=\"color:#0056b3 !important;text-decoration:underline !important;\"\u003e21999-0200\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;text-align:left;vertical-align:top;padding:12px 14px;border:1px solid #d9dde2;\"\u003eActivated carbon service kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;text-align:left;vertical-align:top;padding:12px 14px;border:1px solid #d9dde2;\"\u003e\u003ca href=\"\/products\/tsunami-50-series-activated-carbon-element-5-pack-pn-21999-0826?variant=40192947486790\" style=\"color:#0056b3 !important;text-decoration:underline !important;\"\u003e21999-0826\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;text-align:left;vertical-align:top;padding:12px 14px;border:1px solid #d9dde2;\"\u003eActivated carbon replacement elements, five-pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;text-align:left;vertical-align:top;padding:12px 14px;border:1px solid #d9dde2;\"\u003e\u003ca href=\"\/products\/tsunami-21999-0819-50-series-annual-filter-maintenance-kit\" style=\"color:#0056b3 !important;text-decoration:underline !important;\"\u003e21999-0819\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;text-align:left;vertical-align:top;padding:12px 14px;border:1px solid #d9dde2;\"\u003eAnnual filter kit: two coalescing + two carbon elements and O-rings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;text-align:left;vertical-align:top;padding:12px 14px;border:1px solid #d9dde2;\"\u003e\u003ca href=\"\/products\/tsunami-membrane-dryer-core-pn-21999-0355?variant=31497999351878\" style=\"color:#0056b3 !important;text-decoration:underline !important;\"\u003e21999-0355\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;text-align:left;vertical-align:top;padding:12px 14px;border:1px solid #d9dde2;\"\u003eReplacement membrane dryer core\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;text-align:left;vertical-align:top;padding:12px 14px;border:1px solid #d9dde2;\"\u003e\u003ca href=\"\/products\/tsunami-compressed-air-system-component-pressure-regulator-1-2-npt-89-scfm-pn-21999-0871?variant=40457763225670\" style=\"color:#0056b3 !important;text-decoration:underline !important;\"\u003e21999-0871\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;text-align:left;vertical-align:top;padding:12px 14px;border:1px solid #d9dde2;\"\u003eReplacement outlet regulator with gauge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;text-align:left;vertical-align:top;padding:12px 14px;border:1px solid #d9dde2;\"\u003e\u003ca href=\"\/products\/tsunami-moisture-minder-electronic-self-cleaning-drain-valve-up-to-300-cfm?variant=39460077633606\" style=\"color:#0056b3 !important;text-decoration:underline !important;\"\u003e21999-0177\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;text-align:left;vertical-align:top;padding:12px 14px;border:1px solid #d9dde2;\"\u003eElectronic drain; confirm voltage and existing drain configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;margin:0 0 16px !important;\"\u003e\u003ca href=\"\/collections\/tsunami-parts\"\u003eBrowse all Tsunami Parts\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2 style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;font-size:22px !important;line-height:1.35 !important;margin:28px 0 18px !important;\"\u003eMaintenance and Installation\u003c\/h2\u003e\n\u003cul style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;list-style-type:disc !important;padding-left:26px !important;\"\u003e\n\u003cli style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;display:list-item !important;margin:0 0 8px !important;\"\u003e\n\u003cstrong\u003eEvery six months:\u003c\/strong\u003e Inspect the water separator element and replace the oil coalescing element. Replace the activated carbon element at the same interval.\u003c\/li\u003e\n\u003cli style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;display:list-item !important;margin:0 0 8px !important;\"\u003eMaintain effective pre-filtration to protect the membrane from oil contamination.\u003c\/li\u003e\n\u003cli style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;display:list-item !important;margin:0 0 8px !important;\"\u003eMount the filters upright and pressurize the assembly slowly. For paint applications, install outside the spray booth to avoid exposure to bake-cycle heat.\u003c\/li\u003e\n\u003cli style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;display:list-item !important;margin:0 0 8px !important;\"\u003eIsolate the air supply, release all pressure and disconnect electronic drain power before service.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;font-size:22px !important;line-height:1.35 !important;margin:28px 0 18px !important;\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3 style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;font-size:20px !important;margin:24px 0 14px !important;\"\u003eDoes this dryer use compressed air during operation?\u003c\/h3\u003e\n\u003cp style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;margin:0 0 16px !important;\"\u003eYes. Sweep air carries separated moisture out of the membrane housing. Include this demand when sizing your compressor and close the inlet valve when the dryer is not in use, following the operating instructions.\u003c\/p\u003e\n\u003ch3 style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;font-size:20px !important;margin:24px 0 14px !important;\"\u003eWhat is the difference between two-stage and three-stage models?\u003c\/h3\u003e\n\u003cp style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;margin:0 0 16px !important;\"\u003eTwo-stage models include water separation and oil coalescing filtration. Precision three-stage models add activated carbon filtration for oil vapor and use an electronic drain.\u003c\/p\u003e\n\u003ch3 style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;font-size:20px !important;margin:24px 0 14px !important;\"\u003eCan you help me select the right flow rating?\u003c\/h3\u003e\n\u003cp style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;margin:0 0 16px !important;\"\u003eYes. Call \u003ca href=\"tel:8772472381\"\u003e877.247.2381\u003c\/a\u003e with your inlet pressure, temperature, required airflow and dryness target.\u003c\/p\u003e\n\u003ch2 style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;font-size:22px !important;line-height:1.35 !important;margin:28px 0 18px !important;\"\u003eInstallation and Maintenance Manual\u003c\/h2\u003e\n\u003cp style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;margin:0 0 16px !important;\"\u003e\u003ca href=\"https:\/\/www.gosuburban.com\/hubfs\/INST-21999-0889.pdf\" target=\"_blank\" rel=\"noopener\"\u003eDownload the membrane dryer installation and maintenance manual\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Tsunami","offers":[{"title":"Default Title","offer_id":51057210785862,"sku":"21999-0524","price":2409.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0014\/6237\/0374\/files\/21999-0524_new_20color_WEB-1.png?v=1794867269","url":"https:\/\/www.compressedairadvisors.com\/products\/tsunami-20-cfm-3-stage-membrane-dryer-21999-0524","provider":"Compressed Air Advisors Online, Inc. ","version":"1.0","type":"link"}