{"product_id":"tsunami-21999-0177-230-electronic-timer-drain-230v","title":"Tsunami 21999-0177-230 Electronic Timer Drain, 230V","description":"\u003cdiv style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;color:#222;\"\u003e\n\u003ch1 style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;font-size:26px !important;font-weight:700 !important;margin:0 0 18px !important;\"\u003eTsunami 21999-0177-230 Moisture Minder Electronic Drain — 230 VAC\u003c\/h1\u003e\n\u003cp style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;margin:0 0 16px !important;\"\u003eThe \u003cstrong\u003eTsunami 21999-0177-230 Moisture Minder Electronic Drain\u003c\/strong\u003e automatically discharges condensate from compatible compressor tanks, filters, aftercoolers, dryers and drip legs. This version operates on \u003cstrong\u003e230 VAC \/ 60 Hz\u003c\/strong\u003e and uses a solid-state adjustable timer to control how long the solenoid opens and how much time passes between drain events.\u003c\/p\u003e\n\u003cp style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;margin:0 0 16px !important;\"\u003eAn integrated strainer intercepts larger debris before it reaches the valve orifice. The built-in manual flush valve lets the operator clear collected contamination from the strainer path, helping reduce fouling of the valve mechanism. The timer’s test button supports routine operating checks.\u003c\/p\u003e\n\u003cp style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;margin:0 0 16px !important;\"\u003e\u003cstrong\u003eChoose the correct voltage before ordering.\u003c\/strong\u003e This is a powered timer drain; it does not require an intermittent pneumatic pilot signal. It opens according to the timer setting rather than sensing liquid level, so adjust the cycle to the actual condensate load.\u003c\/p\u003e\n\u003ch2 style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;font-size:22px !important;line-height:1.35 !important;font-weight:700 !important;margin:26px 0 14px !important;\"\u003eKey Features\u003c\/h2\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;margin:0 0 24px;\"\u003e\u003ctable style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;width:100% !important;border-collapse:collapse !important;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;text-align:left !important;padding:12px 14px !important;border:1px solid #d9dde2 !important;background:#f1f4f7 !important;\"\u003eFeature\u003c\/th\u003e\n\u003cth style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;text-align:left !important;padding:12px 14px !important;border:1px solid #d9dde2 !important;background:#f1f4f7 !important;\"\u003eBenefit \/ Function\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;line-height:1.5 !important;text-align:left !important;vertical-align:top !important;padding:12px 14px !important;border:1px solid #d9dde2 !important;\"\u003eAdjustable Electronic Timer\u003c\/td\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;line-height:1.5 !important;text-align:left !important;vertical-align:top !important;padding:12px 14px !important;border:1px solid #d9dde2 !important;\"\u003eControls discharge duration and time between drain events.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;line-height:1.5 !important;text-align:left !important;vertical-align:top !important;padding:12px 14px !important;border:1px solid #d9dde2 !important;\"\u003eTest Button\u003c\/td\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;line-height:1.5 !important;text-align:left !important;vertical-align:top !important;padding:12px 14px !important;border:1px solid #d9dde2 !important;\"\u003eProvides an accessible way to check drain actuation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;line-height:1.5 !important;text-align:left !important;vertical-align:top !important;padding:12px 14px !important;border:1px solid #d9dde2 !important;\"\u003eIntegrated Strainer\u003c\/td\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;line-height:1.5 !important;text-align:left !important;vertical-align:top !important;padding:12px 14px !important;border:1px solid #d9dde2 !important;\"\u003eTraps larger contaminants before they reach the orifice.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;line-height:1.5 !important;text-align:left !important;vertical-align:top !important;padding:12px 14px !important;border:1px solid #d9dde2 !important;\"\u003eManual Flush \/ Blowdown Valve\u003c\/td\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;line-height:1.5 !important;text-align:left !important;vertical-align:top !important;padding:12px 14px !important;border:1px solid #d9dde2 !important;\"\u003eAllows manual clearing of trapped material from the strainer path.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;line-height:1.5 !important;text-align:left !important;vertical-align:top !important;padding:12px 14px !important;border:1px solid #d9dde2 !important;\"\u003eStainless Internal Armature and Shaft\u003c\/td\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;line-height:1.5 !important;text-align:left !important;vertical-align:top !important;padding:12px 14px !important;border:1px solid #d9dde2 !important;\"\u003eDurable internal components for condensate-drain service.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;line-height:1.5 !important;text-align:left !important;vertical-align:top !important;padding:12px 14px !important;border:1px solid #d9dde2 !important;\"\u003eDual-Size Inlet\u003c\/td\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;line-height:1.5 !important;text-align:left !important;vertical-align:top !important;padding:12px 14px !important;border:1px solid #d9dde2 !important;\"\u003e1\/4-inch female NPT or 1\/2-inch male NPT connection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;line-height:1.5 !important;text-align:left !important;vertical-align:top !important;padding:12px 14px !important;border:1px solid #d9dde2 !important;\"\u003e4 mm Internal Orifice\u003c\/td\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;line-height:1.5 !important;text-align:left !important;vertical-align:top !important;padding:12px 14px !important;border:1px solid #d9dde2 !important;\"\u003ePublished valve-orifice size.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;line-height:1.5 !important;text-align:left !important;vertical-align:top !important;padding:12px 14px !important;border:1px solid #d9dde2 !important;\"\u003eOptional Installation Kit\u003c\/td\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;line-height:1.5 !important;text-align:left !important;vertical-align:top !important;padding:12px 14px !important;border:1px solid #d9dde2 !important;\"\u003eSupports the remote mounting and tubing arrangement shown in the instructions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch2 style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;font-size:22px !important;line-height:1.35 !important;font-weight:700 !important;margin:26px 0 14px !important;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;margin:0 0 24px;\"\u003e\u003ctable style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;width:100% !important;border-collapse:collapse !important;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;text-align:left !important;padding:12px 14px !important;border:1px solid #d9dde2 !important;background:#f1f4f7 !important;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;text-align:left !important;padding:12px 14px !important;border:1px solid #d9dde2 !important;background:#f1f4f7 !important;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;line-height:1.5 !important;text-align:left !important;vertical-align:top !important;padding:12px 14px !important;border:1px solid #d9dde2 !important;\"\u003eManufacturer Part Number\u003c\/td\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;line-height:1.5 !important;text-align:left !important;vertical-align:top !important;padding:12px 14px !important;border:1px solid #d9dde2 !important;\"\u003e21999-0177-230\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;line-height:1.5 !important;text-align:left !important;vertical-align:top !important;padding:12px 14px !important;border:1px solid #d9dde2 !important;\"\u003eDrain Type\u003c\/td\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;line-height:1.5 !important;text-align:left !important;vertical-align:top !important;padding:12px 14px !important;border:1px solid #d9dde2 !important;\"\u003eElectronic timed-solenoid condensate drain\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;line-height:1.5 !important;text-align:left !important;vertical-align:top !important;padding:12px 14px !important;border:1px solid #d9dde2 !important;\"\u003eElectrical Supply\u003c\/td\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;line-height:1.5 !important;text-align:left !important;vertical-align:top !important;padding:12px 14px !important;border:1px solid #d9dde2 !important;\"\u003e230 VAC \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;line-height:1.5 !important;text-align:left !important;vertical-align:top !important;padding:12px 14px !important;border:1px solid #d9dde2 !important;\"\u003ePublished Current Draw\u003c\/td\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;line-height:1.5 !important;text-align:left !important;vertical-align:top !important;padding:12px 14px !important;border:1px solid #d9dde2 !important;\"\u003e.08 amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;line-height:1.5 !important;text-align:left !important;vertical-align:top !important;padding:12px 14px !important;border:1px solid #d9dde2 !important;\"\u003eMaximum Working Pressure\u003c\/td\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;line-height:1.5 !important;text-align:left !important;vertical-align:top !important;padding:12px 14px !important;border:1px solid #d9dde2 !important;\"\u003e230 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;line-height:1.5 !important;text-align:left !important;vertical-align:top !important;padding:12px 14px !important;border:1px solid #d9dde2 !important;\"\u003eMaximum Operating Temperature\u003c\/td\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;line-height:1.5 !important;text-align:left !important;vertical-align:top !important;padding:12px 14px !important;border:1px solid #d9dde2 !important;\"\u003e175°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;line-height:1.5 !important;text-align:left !important;vertical-align:top !important;padding:12px 14px !important;border:1px solid #d9dde2 !important;\"\u003eInlet Connection\u003c\/td\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;line-height:1.5 !important;text-align:left !important;vertical-align:top !important;padding:12px 14px !important;border:1px solid #d9dde2 !important;\"\u003e1\/4\" NPT female \/ 1\/2\" NPT male\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;line-height:1.5 !important;text-align:left !important;vertical-align:top !important;padding:12px 14px !important;border:1px solid #d9dde2 !important;\"\u003eDischarge Connection\u003c\/td\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;line-height:1.5 !important;text-align:left !important;vertical-align:top !important;padding:12px 14px !important;border:1px solid #d9dde2 !important;\"\u003e1\/4\" NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;line-height:1.5 !important;text-align:left !important;vertical-align:top !important;padding:12px 14px !important;border:1px solid #d9dde2 !important;\"\u003eInternal Orifice\u003c\/td\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;line-height:1.5 !important;text-align:left !important;vertical-align:top !important;padding:12px 14px !important;border:1px solid #d9dde2 !important;\"\u003e4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;line-height:1.5 !important;text-align:left !important;vertical-align:top !important;padding:12px 14px !important;border:1px solid #d9dde2 !important;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;line-height:1.5 !important;text-align:left !important;vertical-align:top !important;padding:12px 14px !important;border:1px solid #d9dde2 !important;\"\u003e5.5 × 3.5 × 3.5 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;line-height:1.5 !important;text-align:left !important;vertical-align:top !important;padding:12px 14px !important;border:1px solid #d9dde2 !important;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;line-height:1.5 !important;text-align:left !important;vertical-align:top !important;padding:12px 14px !important;border:1px solid #d9dde2 !important;\"\u003eApproximately 1 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;line-height:1.5 !important;text-align:left !important;vertical-align:top !important;padding:12px 14px !important;border:1px solid #d9dde2 !important;\"\u003eExternal Pneumatic Pilot\u003c\/td\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;line-height:1.5 !important;text-align:left !important;vertical-align:top !important;padding:12px 14px !important;border:1px solid #d9dde2 !important;\"\u003eNot required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;line-height:1.5 !important;text-align:left !important;vertical-align:top !important;padding:12px 14px !important;border:1px solid #d9dde2 !important;\"\u003ePublished Warranty\u003c\/td\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;line-height:1.5 !important;text-align:left !important;vertical-align:top !important;padding:12px 14px !important;border:1px solid #d9dde2 !important;\"\u003e90 days, subject to manufacturer terms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch2 style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;font-size:22px !important;line-height:1.35 !important;font-weight:700 !important;margin:26px 0 14px !important;\"\u003eTypical Applications\u003c\/h2\u003e\n\u003cp style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;margin:0 0 16px !important;\"\u003eUse at compatible condensate collection points on receiver tanks, aftercoolers, dryers, filters and distribution-system drip legs. Removing accumulated liquid helps reduce water carryover into downstream equipment. Select the installation for the collection point, operating pressure, temperature, available electrical power and condensate load.\u003c\/p\u003e\n\u003cp style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;margin:0 0 16px !important;\"\u003eFor direct installation on a 20 CFM Tsunami filter, the manufacturer’s instructions call for the appropriate 1\/4-inch-to-1\/8-inch reducer connection. Other filter or tank installations may need different fittings or tubing. Verify the installed ports before ordering adapters.\u003c\/p\u003e\n\u003ch2 style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;font-size:22px !important;line-height:1.35 !important;font-weight:700 !important;margin:26px 0 14px !important;\"\u003eHow to Set the Timer\u003c\/h2\u003e\n\u003cp style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;margin:0 0 16px !important;\"\u003e\u003cstrong\u003eON time\u003c\/strong\u003e is the duration of each discharge. \u003cstrong\u003eOFF time\u003c\/strong\u003e is the interval between openings. The installation manual recommends an initial ON time of approximately \u003cstrong\u003e0.5–2 seconds\u003c\/strong\u003e and an OFF interval of \u003cstrong\u003e5 minutes\u003c\/strong\u003e, followed by adjustment for the moisture load.\u003c\/p\u003e\n\u003cp style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;margin:0 0 16px !important;\"\u003eCheck the actual discharge rather than treating the starting settings as correct for every system. Seasonal humidity and operating hours can change condensate production. An overly long ON time or unnecessarily short OFF interval can release compressed air after liquid has cleared; an interval that is too long can allow liquid to accumulate.\u003c\/p\u003e\n\u003ch2 style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;font-size:22px !important;line-height:1.35 !important;font-weight:700 !important;margin:26px 0 14px !important;\"\u003eStrainer Flushing and Maintenance\u003c\/h2\u003e\n\u003cp style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;margin:0 0 16px !important;\"\u003e\u003cstrong\u003eSelf-cleaning does not mean maintenance-free.\u003c\/strong\u003e The built-in flush feature is operated manually to clear accumulated contaminants from the strainer path. Inspect the strainer and discharge tubing, test actuation and follow the manufacturer’s cleaning procedure as conditions require.\u003c\/p\u003e\n\u003cp style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;margin:0 0 16px !important;\"\u003eKeep discharge and flush lines secured and directed to suitable condensate collection or treatment. Isolate and depressurize the system, and disconnect electrical power before disassembly or service. Check for leaks and correct operation before returning the drain to use.\u003c\/p\u003e\n\u003ch2 style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;font-size:22px !important;line-height:1.35 !important;font-weight:700 !important;margin:26px 0 14px !important;\"\u003eInstallation Kit and Voltage Selection\u003c\/h2\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;margin:0 0 24px;\"\u003e\u003ctable style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;width:100% !important;border-collapse:collapse !important;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;text-align:left !important;padding:12px 14px !important;border:1px solid #d9dde2 !important;background:#f1f4f7 !important;\"\u003eItem\u003c\/th\u003e\n\u003cth style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;text-align:left !important;padding:12px 14px !important;border:1px solid #d9dde2 !important;background:#f1f4f7 !important;\"\u003eWhat to Order\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;line-height:1.5 !important;text-align:left !important;vertical-align:top !important;padding:12px 14px !important;border:1px solid #d9dde2 !important;\"\u003e\u003ca href=\"\/products\/tsunami-21999-0316-electronic-drain-installation-kit\" style=\"color:#0056b3 !important;text-decoration:underline !important;text-underline-offset:2px;font-weight:700 !important;\"\u003e21999-0316 Electronic Drain Installation Kit\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;line-height:1.5 !important;text-align:left !important;vertical-align:top !important;padding:12px 14px !important;border:1px solid #d9dde2 !important;\"\u003eOptional installation hardware and tubing arrangement; drain valve sold separately.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;line-height:1.5 !important;text-align:left !important;vertical-align:top !important;padding:12px 14px !important;border:1px solid #d9dde2 !important;\"\u003e\u003ca href=\"\/products\/tsunami-moisture-minder-electronic-self-cleaning-drain-valve-up-to-300-cfm\" style=\"color:#0056b3 !important;text-decoration:underline !important;text-underline-offset:2px;font-weight:700 !important;\"\u003e21999-0177 — 115 VAC drain\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;line-height:1.5 !important;text-align:left !important;vertical-align:top !important;padding:12px 14px !important;border:1px solid #d9dde2 !important;\"\u003eMatch the drain’s electrical supply and nameplate to your installation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;line-height:1.5 !important;text-align:left !important;vertical-align:top !important;padding:12px 14px !important;border:1px solid #d9dde2 !important;\"\u003e\u003ca href=\"\/products\/tsunami-21999-0177-230-electronic-timer-drain-230v\" style=\"color:#0056b3 !important;text-decoration:underline !important;text-underline-offset:2px;font-weight:700 !important;\"\u003e21999-0177-230 — 230 VAC drain\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;line-height:1.5 !important;text-align:left !important;vertical-align:top !important;padding:12px 14px !important;border:1px solid #d9dde2 !important;\"\u003eMatch the drain’s electrical supply and nameplate to your installation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;margin:0 0 16px !important;\"\u003eThe 21999-0316 kit is for electronic-drain installation. It is different from the pneumatic-drain installation kit. The manual shows mounting the electronic drain on a bracket, routing condensate to the inlet and routing discharge and flush tubing to collection.\u003c\/p\u003e\n\u003ch2 style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;font-size:22px !important;line-height:1.35 !important;font-weight:700 !important;margin:26px 0 14px !important;\"\u003eProduct Literature\u003c\/h2\u003e\n\u003cp style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;margin:0 0 16px !important;\"\u003e\u003ca href=\"https:\/\/www.gosuburban.com\/hubfs\/Electronic%20Drain%20Valve%20Installation%20Instruction%2021999-0177%2021999-0316.pdf\" style=\"color:#0056b3 !important;text-decoration:underline !important;text-underline-offset:2px;font-weight:700 !important;\"\u003eElectronic Drain and Installation Kit Manual\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.gosuburban.com\/tsunami\/products\/drains\/moisture-minder-electronic-drain-valve\" style=\"color:#0056b3 !important;text-decoration:underline !important;text-underline-offset:2px;font-weight:700 !important;\"\u003eManufacturer Electronic Drain Specifications\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2 style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;font-size:22px !important;line-height:1.35 !important;font-weight:700 !important;margin:26px 0 14px !important;\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3 style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;font-size:18px !important;font-weight:700 !important;margin:22px 0 10px !important;\"\u003eDoes it need a pneumatic pilot signal?\u003c\/h3\u003e\n\u003cp style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;margin:0 0 16px !important;\"\u003eNo. This model uses its electrical timer and solenoid. A pneumatic piston drain is a different design and needs an intermittent air pilot.\u003c\/p\u003e\n\u003ch3 style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;font-size:18px !important;font-weight:700 !important;margin:22px 0 10px !important;\"\u003eIs it a zero-air-loss, level-sensing drain?\u003c\/h3\u003e\n\u003cp style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;margin:0 0 16px !important;\"\u003eNo. It opens at the programmed intervals. Set the timing to remove condensate without unnecessarily long air discharge.\u003c\/p\u003e\n\u003ch3 style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;font-size:18px !important;font-weight:700 !important;margin:22px 0 10px !important;\"\u003eDoes the strainer flush itself automatically?\u003c\/h3\u003e\n\u003cp style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;margin:0 0 16px !important;\"\u003eThe flush valve is manually operated. Use the test and flush features and inspect the drain according to the installation instructions.\u003c\/p\u003e\n\u003ch3 style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;font-size:18px !important;font-weight:700 !important;margin:22px 0 10px !important;\"\u003eIs the installation kit included?\u003c\/h3\u003e\n\u003cp style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;margin:0 0 16px !important;\"\u003eNo. Order the 21999-0316 kit separately if its mounting and tubing arrangement suits your collection point.\u003c\/p\u003e\n\u003ch3 style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;font-size:18px !important;font-weight:700 !important;margin:22px 0 10px !important;\"\u003eCan I run this version on a different voltage?\u003c\/h3\u003e\n\u003cp style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;margin:0 0 16px !important;\"\u003eSelect the 230 VAC version only when it matches the required supply and nameplate. Choose the other listed AC version when that supply is needed; do not assume one model accepts both voltages.\u003c\/p\u003e\n\u003ch2 style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;font-size:22px !important;line-height:1.35 !important;font-weight:700 !important;margin:26px 0 14px !important;\"\u003eShipping and Expert Help\u003c\/h2\u003e\n\u003cp style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;margin:0 0 16px !important;\"\u003eContact us for current availability and lead time. Free standard shipping applies to eligible domestic orders of $199 or more.\u003c\/p\u003e\n\u003cp style=\"font-family:Arial,Helvetica,sans-serif !important;font-size:16px !important;line-height:1.65 !important;margin:0 0 16px !important;\"\u003eCall \u003ca href=\"tel:8772472381\" style=\"color:#0056b3 !important;text-decoration:underline !important;text-underline-offset:2px;font-weight:700 !important;\"\u003e877.247.2381\u003c\/a\u003e with your collection point, supply voltage, pressure and temperature for help selecting the drain and fittings.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Tsunami","offers":[{"title":"Default Title","offer_id":51067597652038,"sku":"21999-0177-230","price":117.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0014\/6237\/0374\/files\/automatic_20compressor_20drain_20valve_Tsunami_2021999-0177_20Electronic_20Drain_20Valve_20w_20shadow.png?v=1794954382","url":"https:\/\/www.compressedairadvisors.com\/products\/tsunami-21999-0177-230-electronic-timer-drain-230v","provider":"Compressed Air Advisors Online, Inc. ","version":"1.0","type":"link"}