The Tsunami Package #6 combines water separator, oil-coalescing filter, activated carbon, pressure regulator with an included mounting bracket. Choose a 20, 50 or 120 CFM model with the matching port size to suit the airflow and installation.
Best suited for: For multi-stage contamination control with local pressure adjustment; selected electronic-drain versions are available. Each variant is a complete package with the components listed below; replacement service parts are sold separately.
The three filtration stages address different forms of contamination: liquid water first, fine liquid aerosols second, and oil vapor last. This is useful when a single water separator or coalescing stage cannot meet the process’s oil-control requirement.
| Component | Purpose |
|---|---|
| Water Separator | Removes condensed liquid water and larger particles, with 10-micron filtration. Its stainless mesh can be cleaned as needed. |
| Oil-Coalescing Filter | Captures fine liquid aerosols and particles; published performance is 0.01-micron filtration and oil-aerosol concentration down to 0.001 ppm under suitable conditions. |
| Activated Carbon | Adsorbs oil vapor remaining after appropriate upstream filtration; published performance is down to 0.003 ppm under suitable conditions. |
| Pressure Regulator | Allows local adjustment of downstream pressure. Select and set it for the tool or process; it is not a substitute for required pressure-relief protection. |
| Mounting Bracket | Included with the package. Select suitable wall fasteners and allow housing-removal clearance. |
| Specification | Package #6 |
|---|---|
| Flow Options | 20 / 50 / 120 CFM; choose the matching variant |
| Port Options | 1/4" / 1/2" / 1" NPT, respectively |
| Maximum Inlet Pressure | 250 PSI |
| Maximum Inlet Temperature | 122°F |
| Pressure Regulator | Included |
| Lubricator | Not included |
| Activated Carbon | Included |
| Mounting Bracket | Included; installation fasteners selected separately |
| Condensate Drain | Float or electronic, by SKU |
| Drying Capability | Filtration package; does not establish a pressure dew point |
| Airflow | Ports | Drain | Flow Arrangement | MPN / SKU |
|---|---|---|---|---|
| 20 CFM | 1/4" NPT | Float | Standard; follow flow arrow | 21999-0678 |
| 20 CFM | 1/4" NPT | Electronic | Standard; follow flow arrow | 21999-0457 |
| 50 CFM | 1/2" NPT | Float | Standard; follow flow arrow | 21999-0257 |
| 50 CFM | 1/2" NPT | Electronic | Standard; follow flow arrow | 21999-0291 |
| 50 CFM | 1/2" NPT | Float | Right to left | 21999-0257-R |
| 120 CFM | 1" NPT | Float | Standard; follow flow arrow | 21999-0258 |
| 20 CFM | 1/4" NPT | Electronic | Right to left | 21999-0457-R |
The part-number links select the exact configuration. Right-to-left variants are identified by the -R suffix. Check the flow arrows, connection size and selected SKU before ordering.
Electronic-drain configurations require electrical power for the timed drain. Check the supplied drain’s voltage and follow its instructions. Float drains respond to collected liquid. The activated-carbon stage is for vapor adsorption and is not a condensate-removal stage.
Choose this package for pneumatic equipment and process branches requiring the treatment functions listed above. Examples include compatible finishing support, control equipment and general manufacturing air; verify each application’s complete air-quality requirements.
If oil-vapor adsorption is unnecessary, compare Package #4 — 2-Stage Filter/Regulator for water separation and coalescing without the carbon stage.
These packages do not replace a dryer when the application requires a controlled pressure dew point. Compare refrigerated dryers and desiccant dryers for water-vapor control. Filtration alone does not certify a complete air supply for breathing or direct food contact.
Select the package for required flow, inlet pressure and temperature. Keep inlet air within 122°F, follow the flow arrow and use the correct standard or reversed arrangement. Secure the mounting bracket to a suitable structure, support pipework and leave clearance to remove the filter housings. Route condensate to appropriate collection and treatment.
Inspect condensate-drain operation and clean the water-separator stainless mesh as needed. It does not have the same fixed six-month element replacement requirement as coalescing and carbon stages.
Replace the oil-coalescing element every six months according to Tsunami’s service instructions. Protect it from bulk-liquid loading with suitable upstream separation. Do not apply the water-separator mesh-cleaning procedure to the coalescing element.
Replace the activated-carbon element every six months. Keep upstream liquid-water and aerosol-removal stages maintained to protect the carbon medium. The annual kits below provide two scheduled services’ worth of coalescing and carbon elements with O-rings.
Set the regulator to the required operating pressure while checking performance under actual flow. Do not treat the regulator as a safety relief valve.
Isolate the package, release all pressure and disconnect drain power where applicable before opening housings or replacing components. Follow the installation manual for service and reassembly.
Sold separately. Match the service row to your complete package’s airflow rating. Separator, coalescing and carbon service elements perform different jobs and are not interchangeable.
Shop Tsunami service parts and accessories
Yes. The package includes its mounting bracket. Select installation fasteners for the supporting surface and package load.
It treats the contaminants addressed by its included filter stages. It does not establish a pressure dew point or prevent water vapor from condensing if the air cools sufficiently downstream. Add a dryer when the process requires one.
Choose by actual air demand, operating pressure, temperature and required air quality. Match the 20, 50 or 120 CFM variant and its port size; connection size alone is not a capacity calculation.
Follow the airflow arrows. Where listed, choose the -R configuration for right-to-left flow rather than connecting a standard package backwards.
Replace coalescing and carbon elements every six months. Clean water-separator mesh as needed if that stage is included.
Free standard shipping on eligible domestic orders of $199 or more. Contact Compressed Air Advisors for current availability, lead time and destination-specific shipping requirements.
Call 877.247.2381 with your airflow, pressure and application for help selecting the right package.
ordering was a breeze and shipping was fast and the quality of the product and the packing was excellent wood buy again and will be when I need a couple more filters